Skip to main content

Tennessee Valley Authority

For the period ended Aug 20, 2026. Filed Aug 25, 2026.

View on SEC.gov

About this filing

A notice of a major event between regular reports, such as results, a deal or a change of executives. It is often the first formal record of the news.

Aug 20, 2026 · Filed Aug 25, 2026

Use the contents to explore the available documents and sections.

TVE$23.21-0.1%Stored close · as of Nov 6, 2026
See the whole filing, with its images and exhibits

Notes

(1) The Personal Safety metric is the Serious Injury Incident Rate, which is a mathematical calculation used by Edison Electric Institute that quantifies the extent of injury for serious injuries and fatalities from events within the control of the employee and/or the employer.

(2) The Nuclear Reliability metric is the Annualized Online Reliability Loss Factor, which is the 12-month ratio of all generation losses minus refueling outage ("RFO") and exempt losses to reference energy generation minus RFO and exempt losses in a normal fuel cycle period, per standard industry guidelines. This measure monitors performance between refueling outages to obtain high unit and energy production reliability.

(3) The Transmission Reliability metric is an aggregate measure of the overall reliability of TVA's transmission system. See Transmission Reliability below.

(4) The Generation Reliability metric is an aggregate measure of the overall reliability of TVA's power operations generation fleet based on key performance measures in Gas, Hydro, and Coal that are intended to ensure that TVA's fleet of power operations generation assets are available and reliable to meet system demand. See Generation Reliability below.

(5) The Cost Performance metric equals the total Non-Fuel Operating & Maintenance ("O&M") and Base Capital expenses for corporate and operational Strategic Business Unit ("SBU") organizations (excluding the Board).

Transmission ReliabilityWeightThresholdTargetStretch
Load Not Served (1)60%4.43.62.7
Outages per Hundred Miles per Year (2)20%2.872.611.98
Connection Point Interruption Frequency (3)20%0.640.530.34

Notes

(1) Load Not Served ("LNS") is a measure of the magnitude and duration of transmission system outages that affect TVA customers expressed in system minutes. TVA manages this critical indicator to reduce the impact of customer outages. An automatic customer interruption with a duration of one minute or greater is tracked as an LNS event. LNS events caused by TVA on a distributor system will also count as a TVA event even if the TVA system remains energized. LNS excludes interruptions due to declared major events, variances, verified tornadoes, gunfire, vandalism, ice formation, and foreign object/vehicle (DUI, DWI, hit and run, or suicide).

(2)Outages per Hundred Miles per Year ("OHMY") is the number of automatic interruptions (sustained and momentary) to lines greater than or equal to 100-kV per 100 miles of transmission line per year. OHMY excludes interruptions due to declared major events, variances, verified tornadoes, gunfire, vandalism, ice formation, foreign object/vehicle (DUI, DWI, hit and run, or suicide), and nested interruptions.

(3) Connection Point Interruption Frequency ("CPIF") measures reliability from the customer's perspective. CPIF tracks interruptions of power, including momentary interruptions, at connection points caused by the transmission system. CPIF includes automatic and emergency forced outages and excludes prearranged (scheduled or planned) and operational outages as well as interruptions due to declared major events, variances, verified tornadoes, gunfire, vandalism, ice formation, and foreign object/vehicle (DUI, DWI, hit and run, or suicide).

Generation ReliabilityWeightThresholdTargetStretch
Combined Cycle Equivalent Forced Outage Rate (1)45%2.5%1.7%1.1%
Hydro Equivalent Forced Outage Rate (2)25%3.7%2.3%1.9%
Coal Equivalent Forced Outage Rate (3)25%4.0%3.0%2.0%
Combustion Turbine Economic Starting Reliability (4)5%99.1%99.3%99.5%

Notes

(1) Combined Cycle Equivalent Forced Outage Rate (“EFOR”) measures the generation lost due to forced events as a percentage of time the unit would have been scheduled to run for TVA-operated combined cycle generating assets, based on Generating Availability Data System (“GADS”) event reporting guidelines for megawatt hour losses. Combined Cycle EFOR excludes GADS events classified as outside management control and variances.

(2)Hydro EFOR measures the generation lost as a result of forced events as a percentage of time the unit would have been scheduled to run, based on GADS event reporting guidelines for megawatt hour losses. Hydro EFOR excludes GADS events classified as outside management control and variances.

(3) Coal EFOR measures the generation lost as a result of forced events as a percentage of time the unit would have been scheduled to run, based on GADS event reporting guidelines for megawatt hour losses. Coal EFOR excludes GADS events classified as outside management control and variances.

(4) Combustion Turbine ("CT") Economic Starting Reliability reflects the percentage of successful attempts to start up a unit for generation, performance testing, or black start over a given period that a generating unit was available for TVA-operated CT assets. Total unit performance tests demonstrate that a unit will start and perform as intended. Black start tests demonstrate that a unit will start without relying on external power and perform as intended. CT Economic Starting Reliability excludes GADS events classified as outside management control and variances.

ContentsView on SEC.gov

The text of this filing, as the company filed it with the SEC, without its images or exhibits. This is not investment advice.