Overview

We are a medical device company focused on developing and commercializing products for the treatment of cardiac arrhythmias with our novel, proprietary, catheter-based Ultra-Low Temperature Ablation (“ULTA”) technology, formerly known as Ultra-Low Temperature Cryoablation (“ULTC”) technology. Our initial focus is on the treatment of ventricular tachycardia (“VT”). VT is a rapid, abnormal heart rhythm, or arrhythmia, that originates in the heart’s lower chambers, or ventricles, potentially leading to impaired blood flow and, if sustained, VT can be fatal. In the United States, VT-associated sudden cardiac death (“SCD”) accounts for approximately 300,000 deaths each year. Radio Frequency (“RF”) ablation catheters currently used to treat VT were primarily designed and approved for the treatment of atrial fibrillation (“AF”) and are therefore not designed to optimally treat the specifics of the ventricular anatomy and disease. As a result, VT procedures performed with current devices can be overly complex, with sub-optimal outcomes, a factor that has potentially led to limited growth in the market for VT ablations.

Our clinically tested, proprietary ULTA products are purpose-built to treat patients with VT and are designed to address the unique anatomy of the ventricle and the specific needs of the VT patient. Our ULTA approach is built on the hypothesis that large and durable lesions extending through the depth of both diseased and healthy muscular tissue of the ventricle of the heart (ventricular myocardium) is a foundation for improving the effectiveness of VT ablations and patient outcomes. Our differentiated catheters and consoles are designed to create titratable, large, durable, deep lesions within the ventricle through a stable, endocardial – or inside the heart - approach with no required irrigation. In October 2025, we announced completion of enrollment in our FULCRUM-VT Pivotal FDA Investigational Device Exemption (“IDE”) study evaluating the vCLASTM Cryoablation System for ablation of monomorphic ventricular tachycardia (MMVT) in patients with both ischemic and non-ischemic cardiomyopathy. The vCLAS System, which was granted Breakthrough Device Designation by the FDA in April 2025, is built on our proprietary ULTA technology platform and is typically utilized with a double freeze cycle (freeze-thaw-freeze) protocol.

We believe that our purpose-built solution has the potential to drive market growth in ablative treatment of the large, underserved VT patient population.

We have established a robust cadence of clinical data designed to evaluate our technology and gain regulatory approvals of our product portfolio. Preliminary data suggest that our approach to treating VT offers a favorable combination of safety, acute and chronic effectiveness, compared to the current standard of care, including ablations performed using RF and pulsed field ablation (“PFA”) energy. Our first-in-human CRYOCURE-VT trial included 64 patients in nine centers in the European Union and Canada. The outcomes of this trial, which were used to support Conformité Européenne (“CE Mark”) approval, include a 0% rate of major adverse events, 94% acute procedural success, 60% freedom from sustained VT and 81% freedom from implantable cardioverter defibrillator (“ICD”) shock at six months. Our vCLASTM. Cryoablation System for VT has obtained European CE Mark approval. In the United States, our 209-patient FULCRUM-VT IDE pivotal clinical trial completed enrollment in October 2025 across 19 centers in the United States and Canada. The study includes patients with both ischemic and non-ischemic (NICM) cardiomyopathies (LVEF=35+/-10%, 33% NICM, 75% with congestive heart failure). In our preliminary acute safety and efficacy results, acute clinical success, defined as non-inducibility of target ventricular arrhythmias, was 97.4%, with all clinically-relevant VTs eliminated in 96.7% of patients tested by post-ablation programmed electrical stimulation. Key safety findings included a 2.4% rate of major adverse events including four (1.9%) peri-procedural deaths, of which one (0.5%) was adjudicated by an independent Clinical Events Committee as definitely related to the investigational device. We plan to share the six-month results of the FULCRUM-VT trial in April 2026 at the Heart Rhythm Society 2026 Conference and to submit the results of this trial to support our application for FDA approval of our vCLASTM Cryoablation System in the first half of 2026.

We are also currently developing a next-generation ULTA technology for VT. This catheter, which requires only a single freeze, is being designed to improve customer usability and integration with the existing ablation laboratory workflow. The next-generation catheter features a more flexible, smaller diameter shaft that is compatible with the industry-standard size 8.5 French sheaths, and is designed to operate at lower ablation temperatures resulting in the shorter, single-freeze ablation protocol. We have completed the design phase with this device.

We have also developed a technology that utilizes ULTA in combination with PFA, which we call Pulsed Field Cryoablation (“PFCA”). Early demonstrations of PFCA technology has been performed in the European PARALELL trial in patients with persistent atrial fibrillation and in preclinical studies targeting VT ablations.

Market Opportunity

The total value of the global market for electrophysiology (“EP”) devices in 2025 was approximately $14 billion, which includes significant recent acceleration in growth of approximately 25% in each 2024 and 2025, driven primarily by increased procedure volumes and the associated higher average selling prices from the introduction and widespread adoption of pulsed field ablation (“PFA”) for AF ablation. This acceleration illustrates the EP market responsiveness to meaningful technological improvements. According to industry sources, longer-term, the market is projected to grow at a compound annual growth rate of approximately 13%, reaching over $33 billion by 2033. We believe that these market trends bode well for future growth in the ablation market for VT, which currently represents a smaller, highly underpenetrated part of the total EP market, partially due to the historic lack of the investment and development of ablation technologies designed for the specific requirements and circumstances of the ventricular anatomy.

Ventricular Tachycardia

VT is a potentially fatal disruption of normal electrical activation of the heart originating in the lower chambers of the heart (ventricles), that is characterized by a heart rate exceeding 100 beats per minute. The symptoms of VT range from lightheadedness to a temporary loss of consciousness caused by a sudden decrease in blood flow to the brain, known as syncope, to progression into ventricular fibrillation and possibly SCD. VT-associated SCD accounts for approximately 300,000 deaths each year in the U.S. alone. VT is prevalent in patients with structural heart disease of both ischemic (related to coronary artery disease) and non-ischemic causes due to electrically disruptive scarring within the muscle of the heart, which blocks or delays normal propagation of the electric signal in the heart. The other relevant group of VT patients are those with “idiopathic” VT, or VT from unknown origin, which is not associated with underlying structural heart disease. This group includes patients with premature ventricular contractions (“PVC”), which are extra heartbeats that begin in one of the heart’s two ventricles. While occasional PVCs in people without underlying heart disease usually are not cause for concern, frequent PVCs can become highly symptomatic and lead to the development of cardiomyopathy, or disease affecting the heart muscle that makes it difficult for the heart to pump blood effectively.

The first-line treatments for structural-related VT are anti-arrhythmic drugs, which are often toxic and poorly tolerated, either alone or in combination with an ICD, which is implanted in the patient to sense and restore normal heart rhythm through the administration of electrical shocks. While ICD implants do address the risk of SCD, the patients remain vulnerable to recurrent symptomatic episodes of VT. These symptomatic VT episodes could prompt harmful ICD shocks, resulting in reduced quality of life, hospitalizations and/or cardiac decompensation, where the heart function becomes unstable.

​Catheter ablation treats VT by addressing the underlying cause of the disease. In these procedures, electrodes at the tip of the catheter use energy to create what are known as myocardial lesions to destroy – or ablate – the electrical pathway in the muscular tissue of the heart that is causing the VT. It is estimated that the total addressable global market for VT ablation is $5.8 billion, which is comprised of approximately 1.6 million patients with VT who are eligible for ablation each year. Within the U.S., the total addressable market for VT is estimated to be $1.6 billion, comprised of 200,000 patients. It is further estimated that there are approximately 100,000 ablations for VT worldwide each year, or approximately 6% of the total addressable VT ablation market. VT ablation procedures have been growing by approximately 7% annually, driven in part by the advances in electroanatomic mapping technologies and operator training as well as by the aging population and the increased incidence of underlying cardiac disease.

​Cardiac ablation to address VT in patients with structural heart disease has been clinically shown to reduce the frequency of symptomatic ventricular arrhythmias, including repeat, uncontrollable arrhythmias known as VT storms, and to reduce ICD shocks. Additionally, the recent VANISH-2 trial demonstrated that VT ablation may be a viable alternative to the escalation of anti-arrhythmic medications; however, current clinical guidelines recommend VT ablation therapy for patients with structural heart disease as second-line therapy. We estimate that approximately 730,000 patients with VT due to structural heart disease are eligible for ablation each year.

​Symptomatic idiopathic VT comprises approximately 60% of current VT ablations. While the indications for ablative treatment of these patient groups vary significantly based on arrhythmia sub-type and site of origin, the estimated annual incidence of the condition is approximately 780,000 per year.

Current Challenges

​Several factors have limited the growth of ablation procedures for VT. Today, VT ablations are performed using RF catheters, which are almost exclusively designed and initially approved to treat atrial arrhythmias. The majority of atrial ablations are performed using a standardized set of lesions in tissue with thickness of 2 to 5 millimeters. In comparison, VT ablations are performed using a patient-specific and often very extensive set of lesions, which vary - depending on the location of the abnormal electrical circuit and preferred ablation strategy - in the forcefully contracting, highly mobile ventricular myocardium where tissue thickness routinely exceeds 10 millimeters.

​The principal issue of RF technology for VT is its limited lesion depth of 5 to 6 millimeters in healthy tissue which is further attenuated, or reduced, by approximately 50% in the presence of the myocardial scar. Furthermore, performing RF ablation requires an operator to maintain consistent mechanical contact between the catheter and the tissue, which can be technically challenging when ablating VT due to ventricular contractions. In addition, in order to cool the ablating electrode and minimize the chance of a life-threatening complication known as “steam-pop”, advanced RF catheters utilize irrigating fluid, which can lead to the development of acute cardiac decompensation, particularly in patients with structural heart disease. Additionally, the insufficient lesion depth with RF can impact the effectiveness of the preferred endocardial (internal surface of the heart) ablation in some patients. RF catheter instability and management of irrigating fluid overload add to the technical challenges of VT ablations.

VT ablations using current technology remain lengthy and technically complex and are associated with a nearly 11.5% rate of serious complications, including death, particularly, but not exclusively, in patients with structural heart disease. This complexity and procedural risk combined with current guidelines for VT ablations as a second-line therapy have limited the growth of the procedural volumes despite significant improvement in the adjunctive technologies such as electroanatomic mapping and emerging evidence on benefits of earlier and prophylactic VT ablations.

Our Solution

​Our proprietary ULTA technology was developed to consistently create large, titratable, durable lesions extending through the depth of both diseased and healthy ventricular myocardium, which we believe is a foundation for improving the effectiveness and outcomes of VT ablations. Our unique technology portfolio consists of ULTA alone and in combination with PFA (also known as PFCA).

Our ULTA technology uses nitrogen (N2) gas, which is pressurized to its critical point and cooled to its ambient boiling temperature of -196°C. This is in contrast to currently available cryoballoon and focal point cryocatheter technologies, which are based on the rapid evaporation (Joule-Thompson effect) of the compressed nitrous oxide (N2O) with a boiling temperature of -88.5°C. In ULTA, the “near- critical” nitrogen combines the flow properties of gas with density and thermal capacity of liquid, making it an ideal refrigerant for use in the endovascular environment. The high pressure suppresses evaporation and ensures continuous, vapor lock-free flow through small lumen catheters. Under such conditions, the refrigerant can be brought into close proximity and applied to the tissue targeted for ablation through a proprietary cryoablation catheter at temperatures close to -196°C. In our pre-clinical experiments, the cryogenic power supplied by the technology was sufficient to achieve the temperatures at or below -30°C deep into the tissue, resulting in formation of intracellular ice and instantaneous and permanent death of cardiac tissue. The size and contiguity of such durable lesions could be assured by length, shape, and mechanical properties of the ablation element, while depth can be titrated by the duration of the freeze.​

Key benefits of ULTA for VT ablations include:

●Titratable lesion depth up to and exceeding 10 millimeters provides physicians a new ability to use simple endocardial-only approach to ablate VT circuits in patients with both ischemic and non-ischemic cardiomyopathy, as well as PVCs.
●​Large lateral size of the lesions enabled by the length and design of the ULTA ablation element offer physicians the possibility to utilize a small number of ablations, performing otherwise complex procedures faster, safely, and effectively.
●​Preservation of intracellular matrix with ULTA avoids potentially life-threatening complications known as steam-pop.
●​Stability from cryoadhesion, or the catheter adhesion to the endocardial surface upon freezing, eliminates the need for the physician to manually maintain contact between the catheter and the tissue during energy delivery, which is of critical importance when ablating in certain anatomic locations, and can also minimize physician’s stress and fatigue.
●​Lack of irrigation with ULTA technology is designed to eliminate the possibility of fluid overload for VT patients and thereby eliminates the associated increased risk of acute cardiac decompensation and renal failure in structural heart disease patients already susceptible to cardio-renal syndrome, potentially also shortening post-procedural recovery time.

Clinical Results

​The performance of our vCLASTM Cryoablation System for ablation of monomorphic VT in patients with structural heart disease was evaluated in the 64-patient CRYOCURE-VT study at nine sites in Europe and Canada. Monomorphic VTs arise from a single aberrant electrical circuit in the ventricle and are the most prevalent type of VT. The CRYOCURE-VT trial supported CE-mark approval of Adagio’s vCLAS Cryoablation System in the first quarter of 2024. The study demonstrated 94% acute procedural success, 60% freedom from VT recurrence and 81% freedom from implantable cardioverter defibrillator shock at six months. In addition, the study demonstrated significant reduction in burden of ventricular arrhythmias and over 50% reduction in use of antiarrhythmic medication. Further analysis demonstrated that these benefits were sustained through twelve months of follow-up and that freedom from VT-related and heart failure-related hospitalizations remained high through the duration of the follow-up.

On November 4, 2022, we received FDA approval to conduct the IDE Early Feasibility Study (“EFS”) of the vCLAS Cryoablation System, which we refer to as the FULCRUM-VT study, in 20 patients with both ischemic and non-ischemic cardiomyopathy at up to 5 sites. On July 13, 2023, the U.S. Center for Medicare and Medicare Services (“CMS”) provided notification that the vCLAS catheter and associated ablation services were approved for the purposes of Medicare coverage. In April 2024 we received FDA approval to convert the EFS study to a single-cohort Pivotal IDE study of our vCLAS Cryoablation System, expanding the number of sites to 20 and the number of U.S. patients to 206, which includes patients with ischemic and non-ischemic heart disease and patients with arrhythmogenic right ventricular cardiomyopathy. This is the first FDA-approved IDE studying VT ablation technology in patients with both ischemic and non-ischemic cardiomyopathy. Subsequently, on September 23, 2024, confirmed that the CMS approval granted for the EFS would remain in effect for the FULCRUM-VT pivotal study.

In April 2025, we announced that we received Breakthrough Device Designation from the FDA for our vCLASTM Cryoablation System for the treatment of drug-refractory, recurrent, sustained monomorphic VT in patients with ischemic or non-ischemic structural heart disease. On October 1, 2025, we announced the completion of enrollment of the FULCRUM-VT pivotal study. Subsequently on October 10, 2025, we announced preliminary acute safety and efficacy results from FULCRUM-VT. Acute clinical success, defined as non-inducibility of target ventricular arrhythmias, was 97.4%, with all clinically-relevant VTs eliminated in 96.7% of patients tested by post-ablation programmed electrical stimulation. Key safety findings included a 2.4% rate of major adverse events including four (1.9%) peri-procedural deaths, of which one (0.5%) was adjudicated by the independent Clinical Events Committee as definitely related to the investigational device. We plan to share the six-month primary efficacy endpoint results of the FULCRUM-VT trial in April 2026 at the Heart Rhythm 2026 Conference and to submit the results of this trial to support our application for FDA approval of our vCLASTM Cryoablation System in the first half of 2026.

Pulsed Field Cryoablation

​Our PFCA technology is intended to combine the proprietary benefits of ULTA and PFA while minimizing their respective limitations. PFCA consists of the short duration ULTA freeze followed by PFA delivered through the same catheter. Our work has shown that ULTA results in a significant increase in the impedance and electric field generated by PFA within the frozen tissue while decreasing electric field and parasitic electric current elsewhere. This latter capability helps eliminate muscle and phrenic nerve capture while minimizing the microbubbles and possibility of vasospasm, thus potentially addressing a key limitation of stand-alone PFA. In effect, ULTA pre-treatment could have the effect to “focus” PFA, further increasing the selectivity of ablation and, since the area of the increased impedance extends deeper in the tissue, PFCA lesions of a desired depth could potentially be achieved.

​The principle of PFCA was demonstrated in PARALLEL study of atrial ablations in patients with persistent atrial fibrillation. In a cohort of the patients with cryogenic energy delivery above the threshold, PFCA was 100% effective in isolation of pulmonary veins and the posterior wall of the left atrium, with fewer than 1% of energy applications accompanied by observations of microbubbles or faint muscle contractions. The pre-clinical investigation of ventricular PFCA in the animal model demonstrated lesion depth is equivalent to the ULTA at half the total freeze duration with minimal attenuation by the scar tissue.

Our Current and Future Product Portfolio

vCLASTM* First Generation Ablation System*

​Our VT Cryoablation System is comprised of the vCLAS™ catheter and ULTA cryoablation console. The vCLAS ventricular catheter has been purposefully designed for the treatment of the ventricular arrhythmia. The 9 French bi-directionally deflectable catheter features a 15 millimeter long, non-flexible ablation element with eight electrodes for intracardiac sensing/pacing.

vCLASTM* ULTRA Second Generation Ablation System*

​We are also currently developing a next-generation ULTA technology, the vCLASTM ULTRA, for ventricular ablation, the design of which is faster, smaller and more flexible than its predecessor vCLAS device. This catheter, which requires only a single freeze, is being designed to improve customer usability and integration with the existing ablation laboratory workflow. The next-generation catheter features a more flexible, smaller diameter shaft that is compatible with the industry-standard size 8.5 French sheaths, and is designed to operate at lower ablation temperatures resulting in the shorter, single-freeze ablation protocol. We have completed the design phase with this device.

Competition

​The major players in cardiac EP and advanced ablation catheter markets are Biosense Webster, Inc. (a division of Johnson & Johnson), Abbott, Medtronic, and Boston Scientific. Today, VT ablations are predominantly performed using point-by-point RF ablation catheter technology. In the U.S. the RF catheters by Biosense Webster (Navistar™ Thermocool® Deflectable Diagnostic/Ablation Catheter) and Abbott Electrophysiology (FlexAbility™ Ablation Catheter, Sensor Enabled™), both originally designed for treatment of AF, have expanded indications for the ablation of sustained, drug-refractory monomorphic ventricular tachycardia.

​Saline-enhanced RF needle catheter has been suggested to overcome lesion-depth limitations of the standard RF ablations. The needle can be inserted deeper into myocardial tissue and the injected saline creates a virtual electrode for RF application, resulting in large and deep (9.9 ± 2.7 millimeter) myocardial lesions in the preclinical models. Several small clinical studies on catheters of two principal designs have been conducted in patients with both structural heart disease VTs and PVCs, all demonstrating moderate effectiveness with 13-20% rates of serious complications.

​The rapid adoption of PFA technology for ablation of atrial arrhythmias has spurred interest in applying PFA to ventricular ablations. In addition to the need for irrigation to manage the heat from PFA and for the use of nitroglycerin to try to prevent vasospasm, where high-energy fields of PFA have been shown to trigger smooth muscle contraction, reducing blood flow, we believe the use of PFA in VT may require significant adjustment to achieve the lesion depth required for ventricular ablations. Such changes, which could include substantial increases in pulse voltage, could have related risks including harm to otherwise healthy tissue in the heart. To date, the clinical evidence for ventricular PFA is limited to a small number of cases associated with early feasibility studies and a small case series of off-label use of atrial PFA catheters, primarily in ischemic VTs. We are currently not aware of any IDE studies in the U.S. for the use of PFA in VT.

Intellectual Property

​Our policy is to seek to protect our proprietary position by, among other methods, pursuing and obtaining patent protection in the United States and in jurisdictions outside of the United States related to our technology, inventions, improvements and products that are important to the development and implementation of our business. Our patent portfolio consists of 85 issued patents and 25 patent applications in the United States, Japan, China, Australia, Republic of Korea, Brazil, Israel, United Kingdom, and countries of European Union, covering more than 20 patent families ranging from the disclosures of foundational ULTA technology to the details and components of catheter and accessory designs. More recently issued patents are directed to Tissue Contact Verification, VT- and multi-modality PFCA catheters. We believe that in combination with the trade secrets and other proprietary information related to the manufacturing processes of catheters and consoles, this patent portfolio creates significant entry barrier for competitive ULTA and PFCA entries near term, allowing us to remain a single-source provider of these differentiating technologies in Cardiac EP. However, trade secrets and proprietary information can be difficult to protect. We seek to protect our trade secrets and proprietary information, in part, by confidentiality agreements and proprietary invention assignment agreements with our employees, consultants, scientific advisors and contractors. We also seek to preserve the integrity and confidentiality of our data and trade secrets by maintaining physical security of our premises and physical and electronic security of our information technology systems. While we have confidence in the measures we take to protect and preserve our trade secrets and proprietary information, there may be instances in which they may not provide meaningful protection. Such measures can be breached, and we may not have adequate remedies for any such breach. In addition, our trade secrets may otherwise become known or be independently discovered by competitors or misused by any collaborator to whom we disclose such information. Despite any measures taken to protect our intellectual property, unauthorized parties may attempt to copy aspects of our products or to obtain or use information that we regard as proprietary. As a result, we may be unable to meaningfully protect our trade secrets and proprietary information.

​Our trademark portfolio covers all of the main product families: iCLAS™ for ULTA AF ablation catheter and system, vCLAS™ for ULTA VT catheter, and Cryopulse™ for PFCA catheters. The trademarks have been registered or pending in Canada, United Kingdom, United States and European Union. We maintain our priority filings for trademarks in the United States through periodic extensions to ensure their availability at the time of products’ commercial availability in the United States.

Government Regulation.

U.S. Food & Drug Administration

​Our products and operations are subject to extensive and ongoing regulation by the FDA under the Federal Food, Drug, and Cosmetic Act (“FDCA”), and its implementing regulations, as well as other federal and state regulatory bodies in the United States. The laws and regulations govern, among other things, product design and development, laboratory testing, preclinical and clinical testing, manufacturing and release, packaging, labeling, storage, record keeping and reporting, premarket clearance or approval, establishment registration and device listing, marketing, distribution, promotion, import and export, product complaints, recalls and field safety corrective actions, and post-marketing surveillance.

​Unless an exemption applies, each new or significantly modified medical device we seek to commercially distribute in the United States will require either a premarket notification to the FDA requesting permission for commercial distribution under Section 510(k) of the FDCA, also referred to as a 510(k) clearance, a de novo classification request, or approval from the FDA of a premarket approval (“PMA”) application. Generally, if a new device is considered low- or moderate-risk and has a predicate that is already on the market under a 510(k) clearance, the FDA will allow that new device to be marketed under a 510(k) clearance; otherwise, a de novo or PMA is required. The 510(k) clearance, de novo classification request and PMA processes can be resource intensive, expensive, and lengthy, and require payment of significant user fees, unless a fee waiver is granted.

Device Classification

​Under the FDCA, medical devices are classified into one of three classes-Class I, Class II, or Class III-depending on the degree of risk associated with each medical device and the extent of control needed to provide reasonable assurances with respect to safety and effectiveness.

​Class I includes devices deemed to be the lowest risk to the patient and are those for which safety and effectiveness can be reasonably assured by adherence to general controls that include compliance with the applicable portions of the FDA’s Quality System Regulation (“QSR”), facility registration and product listing, reporting of adverse events and malfunctions, and appropriate, truthful and non-misleading labeling, advertising and promotional materials. Some Class I devices, called Class I reserved devices, require premarket clearance by the FDA through the 510(k) premarket notification process described below. Most Class I products, however, are exempt from the premarket notification requirements and therefore may be commercially distributed without obtaining 510(k) clearance from the FDA.

​Class II devices are those that are subject to the general controls, and special controls as deemed necessary by the FDA to provide reasonable assurance of the safety and effectiveness of the device. These special controls can include performance standards, patient registries, FDA guidance documents and post-market surveillance. Most Class II devices are subject to premarket review and clearance by the FDA. As a result, most Class II devices require the manufacturer to submit to the FDA a Premarket Notification 510(k) requesting permission to commercially distribute the devices meeting the threshold for substantial equivalence.

​Class III devices include devices deemed by the FDA to pose the greatest risk such as life-supporting or life-sustaining devices, or implantable devices, in addition to those deemed novel and not substantially equivalent following the 510(k) process. The safety and effectiveness of Class III devices cannot be reasonably assured solely by the general controls and special controls described above. Therefore, these devices are subject to the PMA application process, which is generally more costly and time consuming than the 510(k) process.

The Investigational Device Process

​In the United States, absent certain limited exceptions, human clinical trials intended to support medical device clearance, de novo classification, or approval require compliance with FDA investigational device exemption (“IDE”) regulations in 21 CFR Part 812. Trials that present “non-significant risk” do not require FDA review or approval of an IDE application. These non-significant risk trials are deemed to have an approved IDE once certain requirements are addressed, and institutional review board (IRB) approval is obtained. If a device presents a “significant risk” to human health, as defined by the FDA, the sponsor must submit an IDE application to the FDA and obtain IDE approval prior to commencing the human clinical trials. The IDE application must be supported by appropriate data, such as animal and laboratory testing results, showing that the risks to subjects are outweighed by the anticipated benefits and that the testing protocol is scientifically sound. The IDE application must be approved in advance by the FDA for a specified number of subjects at specified study sites. Generally, clinical trials for a significant risk device may begin once the IDE application is approved by the FDA and the trial protocol and informed consent are approved by appropriate IRBs. An IRB is an appropriately constituted group that has been formally designated to review and monitor medical research involving subjects and which has the authority to approve, require modifications in, or disapprove research to protect the rights, safety and welfare of human research subjects. There can be no assurance that submission of an IDE application will result in the ability to commence clinical trials, and although the FDA’s approval of an IDE application allows clinical testing to go forward for a specified number of subjects, it does not bind the FDA to accept the results of the trial as sufficient to prove the product’s safety and effectiveness, even if the trial meets its intended success criteria. All clinical trials must be conducted in accordance with the FDA’s IDE regulations that govern investigational device labeling, prohibit promotion and specify an array of recordkeeping, reporting and monitoring responsibilities of trial sponsors and trial investigators. Clinical trials must further comply with the FDA’s good clinical practice regulations for IRB approval and for informed consent and other human subject protections. Required records and reports are subject to inspection by the FDA. The FDA or the IRB may withdraw approval of a clinical trial, or place a trial on clinical hold at any time for various reasons, including a belief that the risks to study subjects outweigh the benefits or a failure to comply with FDA or IRB requirements. Even if a trial is complete, the results of clinical testing may be unfavorable, or, even if the intended safety and effectiveness success criteria are achieved, may not be considered sufficient for the FDA to grant marketing approval or clearance of a product.

The PMA Approval Process

​Through the PMA application process, the applicant must submit data and information demonstrating reasonable assurance of the safety and effectiveness of the device for its intended use to the FDA’s satisfaction. Accordingly, a PMA application typically includes, but is not limited to, extensive technical information regarding device design and development, data from preclinical studies and one or more clinical trials, a full description of the methods, facilities and controls used for manufacturing, proposed labeling and financial disclosure information for the clinical investigators in device trials. The PMA application must provide valid scientific evidence that demonstrates to the FDA’s satisfaction a reasonable assurance of the safety and effectiveness of the device for its intended use.

​Following receipt of a PMA application, the FDA conducts an administrative review to determine whether the application is sufficiently complete to permit a substantive review. If it is not, the agency will refuse to file the PMA. If it is, the FDA will accept the application for filing and begin the review. The FDA, by statute and by regulation, has 180 days to review a filed PMA application, although the review of an application more often occurs over a significantly longer period. During this review period, the FDA may request additional information or clarification of information already provided, and the FDA may issue a major deficiency letter to the applicant, requesting the applicant’s response to deficiencies communicated by the FDA. The FDA considers a PMA or PMA supplement to have been voluntarily withdrawn if an applicant fails to respond to an FDA request for information (e.g., major deficiency letter) within a total of 360 days. Before approving or denying a PMA, an FDA advisory committee may review the PMA at a public meeting and provide the FDA with the committee’s recommendation on whether the FDA should approve the submission, approve it with specific conditions, or not approve it. The FDA is not bound by the recommendations of an advisory committee, but it considers such recommendations carefully when making decisions.

​Prior to approval of a PMA, the FDA may conduct inspections of the clinical trial data and clinical trial sites, as well as inspections of the manufacturing facility and processes. Overall, the FDA review of a PMA application generally takes between one and three years but may take significantly longer. The FDA can delay, limit or deny approval of a PMA application for many reasons, including:

●​the device may not be shown safe or effective to the FDA’s satisfaction;
●​the data from preclinical studies and/or clinical trials may be found unreliable or insufficient to support approval;
●​the manufacturing process or facilities may not meet applicable requirements;
●​the application contains a false statement of material fact;
●​preclinical or clinical studies were not conducted in accordance with applicable regulations;
●​the proposed device labeling is false or misleading; and
●​changes in FDA approval policies or adoption of new regulations may require additional data.

​If the FDA evaluation of a PMA is favorable, the FDA will issue either an approval letter, or an approvable letter, the latter of which usually contains a number of conditions that must be met in order to secure final approval of the PMA. When and if those conditions have been fulfilled to the satisfaction of the FDA, the agency will issue a PMA approval letter authorizing commercial marketing of the device, subject to the conditions of approval and the limitations established in the approval letter. If the FDA’s evaluation of a PMA application or manufacturing facilities is not favorable, the FDA may deny approval of the PMA or issue a not approvable letter. The FDA also may determine that additional tests or clinical trials are necessary, in which case the PMA approval may be delayed for several months or years while the trials are conducted and data is submitted in an amendment to the PMA, or the PMA is withdrawn and resubmitted when the data are available. The PMA process can be expensive, uncertain and lengthy and a number of devices for which the FDA approval has been sought by other companies have never been approved by the FDA for marketing.

​New PMA applications or PMA supplements are required for modification to the manufacturing process, equipment or facility, quality control procedures, sterilization, packaging, expiration date, labeling, device specifications, ingredients, materials or design of a device that has been approved through the PMA process. PMA supplements often require submission of the same type of information as an initial PMA application, except that the supplement is limited to information needed to support any changes from the device covered by the approved PMA application and may or may not require as extensive technical or clinical data or the convening of an advisory committee panel, depending on the nature of the proposed change.

​In approving a PMA application, as a condition of approval, the FDA may also require some form of post-approval study or post-market surveillance, whereby the applicant conducts a follow-up clinical study or follows certain patient groups for a number of years and makes periodic reports to the FDA on the clinical status of those patients when necessary to protect the public health or to provide additional or longer term safety and effectiveness data for the device. The FDA may also approve a PMA application with other post-approval conditions intended to ensure the safety and effectiveness of the device, such as, among other things, restrictions on labeling, promotion, sale, distribution and use.

Pervasive and Continuing Regulation

​After a device is placed on the market in the U.S., numerous regulatory requirements continue to apply. These include:

●​submitting and updating establishment registration and device listings with the FDA;
●​the FDA’s QSR, which requires manufacturers, including their suppliers, to follow stringent design, testing, control, documentation, record maintenance, including maintenance of complaint and related investigation files, and other quality assurance procedures during all aspects of the manufacturing process;
●​routine or unannounced for-cause device facility inspections by the FDA, which may include the manufacturing facilities of subcontractors;
●​labeling regulations, which prohibit the promotion of products for uncleared, unapproved or off-label uses and impose other restrictions relating to promotional activities;
●​medical device reporting, or MDR, regulations, which require that manufacturers report to the FDA if their device may have caused or contributed to a death or serious injury or malfunctioned in a way that would likely cause or contribute to a death or serious injury if the malfunction were to recur;
●​medical device recalls, which require that manufacturers report to the FDA field corrections or removals of a medical device, provided the recall was initiated to either reduce a risk to health posed by the device, or to remedy a violation of the FDCA caused by the device that may present a risk to health; and
●​post-market surveillance regulations, which apply to certain Class II or III devices when necessary to protect the public health or to provide additional safety and effectiveness data for the device.

​ ​We have obtained a manufacturing license from the California Department of Public Health (“CDPH”). The FDA and CDPH have broad post-market and regulatory enforcement powers. We are (or upon FDA clearance or approval, will be) subject to announced and unannounced inspections by the FDA and the Food and Drug Branch of CDPH to determine our compliance with the QSR and other regulations, and these inspections may include the manufacturing facilities of our suppliers. Additionally, our Notified Body, TÜV SÜD (as defined herein), regularly inspects our manufacturing, design and operational facilities to ensure ongoing ISO 13485:2016 compliance in order to maintain our CE Mark.

​

Failure to comply with applicable regulatory requirements can result in enforcement actions, which may include any of the following sanctions:

●​warning letters, fines, injunctions, consent decrees and civil penalties;
●​repair, replacement, refunds, recall or seizure of our products;
●​operating restrictions, partial suspension or total shutdown of production;
●​refusing our requests for 510(k) clearance or premarket approval of new products, new intended uses or modifications to existing products;
●​withdrawing 510(k) clearance or premarket approvals that may have already been granted; and
●​criminal prosecution.

Export of Our Products

​Export of products subject to the 510(k) notification requirements, but not yet cleared to market in the United States, is permitted with FDA authorization provided certain requirements are met. Similarly, unapproved or uncleared products subject to the PMA requirements may be exported certain statutory criteria are met and we submit a “Simple Notification” to FDA when it begins to export. Importantly, however, export of such products may be limited to certain countries designated by statutory provisions, and petitions may need to be submitted to FDA to enable export to countries other than those designated in the statutory provisions. The petitioning process can be difficult, and FDA may not authorize unapproved or uncleared products to be exported to countries to which a manufacturer wishes to export. Devices that are adulterated, devices whose label and labeling does not comply with requirements of the country receiving the product, and devices that are not promoted in accordance with the law of the receiving country, among others, cannot be exported.

Foreign Government Regulation

​The regulatory review process for medical devices varies from country to country, and many countries also impose product standards, packaging requirements, environmental requirements, labeling requirements and import restrictions on devices. Each country has its own tariff regulations, duties, and tax requirements. Failure to comply with applicable foreign regulatory requirements may subject a company to fines, suspension or withdrawal of regulatory approvals, product recalls, seizure of products, operating restrictions, criminal prosecution or other consequences.

U.S. Federal, State and Foreign Fraud and Abuse Laws

​The federal and state governments have enacted, and actively enforce, a number of laws to address fraud and abuse in federal healthcare programs. Our business is subject to compliance with these laws. Violations of such laws could result in significant civil, criminal and administrative sanctions, damages, disgorgement, monetary fines, possible exclusion from participation in Medicare, Medicaid and other federal healthcare programs, imprisonment, integrity oversight and reporting obligations, contractual damages, reputational harm, diminished profits and future earnings, and curtailment or restructuring of our operations.

Anti-Kickback Statutes

​The federal Anti-Kickback Statute prohibits, among other things, persons from knowingly and willfully soliciting, offering, receiving or providing remuneration, directly or indirectly, in cash or in kind, in exchange for or to induce either the referral of an individual for, or the furnishing, recommending, purchasing, leasing, ordering or arranging for a good or service, for which payment may be made under a federal healthcare program, such as Medicare or Medicaid. A person or entity does not need to have actual knowledge of the statute or specific intent to violate it to have committed a violation.

​The definition of “remuneration” has been broadly interpreted to include anything of value, including, for example, gifts, certain discounts, the furnishing of free supplies, equipment or services, credit arrangements, payment of cash, waivers of payments and providing anything of value at less than fair market value. Several courts have interpreted the statute’s intent requirement to mean that if any one purpose of an arrangement involving remuneration is to induce referrals of federal healthcare covered businesses, the statute has been violated. In addition, the Patient Protection and Affordable Care Act (the “ACA”), as amended by the Health Care and Education Reconciliation Act of 2010, or collectively, the Affordable Care Act, codified case law that a claim including items or services resulting from a violation of the federal Anti-Kickback Statute constitutes a false or fraudulent claim for purposes of the Federal False Claims Act. There are a number of statutory exceptions and regulatory safe harbors protecting some common activities from prosecution, but the exceptions and safe harbors are drawn narrowly and require strict compliance in order to offer protection.

​The failure of a transaction or arrangement to fit precisely within one or more safe harbors does not necessarily mean that it is illegal or that prosecution will be pursued. The legality of the arrangement will be evaluated on a case-by-case basis based on a cumulative review of all of its facts and circumstances. However, conduct and business arrangements that do not fully satisfy an applicable statutory exception or regulatory safe harbor may result in increased scrutiny by government enforcement authorities such as the Office of Inspector General, or OIG, of U.S. Department of Health and Human Services.

​Many states have adopted laws similar to the Anti-Kickback Statute. Some of these state prohibitions apply to referral of recipients for healthcare products or services reimbursed by any source, not only government healthcare programs, and may apply to payments made directly by the patient.

​Government officials have continued their enforcement efforts related to the marketing of healthcare services and products, among other activities, and continue to bring cases against companies, and certain individual sales, marketing and executive personnel, for allegedly offering unlawful inducements to potential or existing customers in an attempt to procure their business.

Federal False Claims Act

​The federal False Claims Act (“FCA”) imposes liability on any person or entity that, among other things, knowingly presents, or causes to be presented, a false or fraudulent claim for payment by a federal healthcare program. The qui tam provisions of the FCA allow a private individual to bring actions on behalf of the federal government alleging that the defendant has violated the FCA and to share in any monetary recovery. In addition, various states have enacted false claims laws analogous to the FCA, and many of these state laws apply where a claim is submitted to any third-party payor and not only a federal healthcare program or other state program.

​When an entity is determined to have violated the FCA, it may be required to pay up to three times the actual damages sustained by the government, plus significant civil fines and penalties. As part of any settlement, the government may require the entity to enter into a corporate integrity agreement, which imposes certain compliance, certification and reporting obligations. There are many potential bases for liability under the FCA. Liability arises, primarily, when an entity knowingly submits, or causes another to submit, a false claim for reimbursement to the federal government. For example, the federal government has used the FCA to assert liability on the basis of kickbacks, or in instances in which manufacturers have provided billing or coding advice to providers that the government considered to be inaccurate. In these cases, the manufacturer faces liability for “causing” a false claim. In addition, the federal government has prosecuted companies under the FCA in connection with off-label promotion of products. Our future activities relating to information affecting federal, state and third-party reimbursement of our products and the sale and marketing of our products may be subject to scrutiny under these laws.

​While we are unaware of any current matters, we are unable to predict whether it will be subject to actions under the FCA or a similar state law, or the impact of such actions. However, the costs of defending such claims, as well as any sanctions imposed, could significantly affect our financial performance.

Civil Monetary Penalties

​The federal Civil Monetary Penalty laws imposes penalties against any person or entity that, among other things, is determined to have presented or caused to be presented a claim to a federal healthcare program that the person knows or should know is for an item or service that was not provided as claimed or is false or fraudulent, or offering or transferring remuneration to a federal healthcare beneficiary that a person knows or should know is likely to influence the beneficiary’s decision to order or receive items or services reimbursable by the government from a particular provider or supplier.

Open Payments

​The Physician Payments Sunshine Act, known as “Open Payments” and enacted as part of the Affordable Care Act, requires certain pharmaceutical and medical device manufacturers of products covered by Medicare, Medicaid or the Children’s Health Insurance Program to report annually to the CMS: direct and indirect payments and other transfers of value to physicians (defined to include doctors, dentists, optometrists, podiatrists, and chiropractors), other healthcare professionals (such as physician assistants and nurse practitioners), and teaching hospitals, and applicable manufacturers and group purchasing organizations. Applicable manufacturers must also report annually ownership and investment interests held by physicians and their immediate family members. Applicable manufacturers are required to submit annual reports to the CMS. Failure to submit required information in a timely, complete and accurate manner may result in significant civil monetary penalties. We are subject to Open Payments and the information it discloses may lead to greater scrutiny, which may result in modifications to established practices and additional costs. Additionally, similar reporting requirements have also been enacted on the state level domestically, and an increasing number of countries worldwide either have adopted or are considering similar laws requiring transparency of interactions with healthcare professionals.

Foreign Corrupt Practices Act

​The Foreign Corrupt Practices Act (“FCPA”) prohibits any U.S. individual; U.S. companies and officers, directors, and employees; foreign subsidiaries of U.S. entities; and agents or intermediaries operating on behalf of a U.S. company from paying, offering, promising to pay, or authorizing payment or offering of anything of value, directly or indirectly, to any foreign government official, government staff member, political party or candidate for the purpose of improperly influencing any act or decision of a foreign government entity to obtain, retain, or direct business. The FCPA also obligates companies whose securities are listed on a national securities exchange in the United States to comply with accounting provisions which require the maintenance of books, records, and accounts that accurately and fairly reflect all transactions and dispositions of assets of the corporation, including international subsidiaries, if any, and to devise and maintain an adequate system of internal accounting controls.

International Laws

​In Europe, various countries have adopted anti-bribery laws providing for severe consequences in the form of criminal penalties and significant fines for individuals or companies committing a bribery offense.

​Violations of these anti-bribery laws, or allegations of such violations, could have a negative impact on our business, results of operations and reputation.

​For instance, in the United Kingdom, the U.K. Bribery Act 2010 covers both public and private sector bribery, and prohibits the offer, provision, or promise to give a financial or other advantage to induce or reward another individual to improperly perform their relevant functions or activities, including any function of a public nature. Bribery of foreign public officials also falls within the scope of the U.K. Bribery Act 2010. An individual found in violation of the U.K. Bribery Act 2010 faces imprisonment of up to ten years. In addition, individuals can be subject to an unlimited fine, as can commercial organizations for failure to prevent bribery.

International Trade Laws

​Our company is subject to other laws and regulations governing its international operations, including regulations administered by the U.S. Department of Commerce’s Bureau of Industry and Security, the U.S. Department of Treasury’s Office of Foreign Assets Control (“OFAC”), and various non-U.S. government entities, including applicable export control regulations, economic sanctions on countries and persons, customs requirements, currency exchange regulations, and transfer pricing regulations.

​Commerce regulates certain “dual use” items, as well as associated foreign assistance. OFAC administers and enforces economic sanctions programs primarily against countries and groups of individuals. Sanctions can be either comprehensive or selective, using the blocking of assets and trade restrictions to accomplish foreign policy and national security goals. U.S. persons must comply with OFAC regulations, including all U.S. citizens and permanent resident aliens regardless of where they are located, all persons and entities within the United States, all U.S. incorporated entities, and their foreign branches. In the cases of certain programs, foreign subsidiaries owned or controlled by U.S. companies also must comply.

​Governmental authorizations may be required before we can export technology, equipment or materials, our services, or to collaborate with foreign entities.

​Failure to comply with export control laws and regulations could expose us to civil or criminal penalties, fines, investigations, more onerous compliance requirements, loss of export privileges, debarment from government contracts or limitations on our ability to enter into contracts with the U.S. government.

HIPAA and HITECH

Regulations promulgated pursuant to the Health Insurance Portability and Accountability Act of 1996 (“HIPAA”), establish privacy and security standards that limit the use and disclosure of individually identifiable health information (known as “protected health information”) and require the implementation of administrative, physical and technological safeguards to protect the privacy of protected health information and ensure the confidentiality, integrity and availability of electronic protected health information. Determining whether protected health information has been handled in compliance with applicable privacy standards and our contractual obligations can require complex factual and statistical analyses and may be subject to changing interpretation. Although we take measures to protect sensitive data from unauthorized access, use or disclosure, our information technology and infrastructure may be vulnerable to attacks by hackers or viruses or breaches due to employee error, malfeasance or other malicious or inadvertent disruptions. Any such breach or interruption could compromise our networks and the information stored there could be accessed by unauthorized parties, manipulated, publicly disclosed, lost or stolen. Any such access, breach or other loss of information could result in legal claims or proceedings, and liability under federal or state laws that protect the privacy of personal information, such as the HIPAA, the Health Information Technology for Economic and Clinical Health Act (“HITECH”), and regulatory penalties. Notice of breaches must be made to affected individuals, the Secretary of the Department of Health and Human Services, and for extensive breaches, notice may need to be made to the media or State Attorneys General. Such a notice could harm our reputation and our ability to compete.

U.S. Health Reform

​Changes in healthcare policy could increase our costs and subject it to additional regulatory requirements that may interrupt commercialization of our current and future solutions. Changes in healthcare policy could increase our costs, decrease our revenue and impact sales of and reimbursement for our current and future products. For example, the ACA substantially changed the way healthcare is financed by both governmental and private insurers, and significantly impacts the life sciences industry. The United States and some foreign jurisdictions are considering or have enacted a number of legislative and regulatory proposals to change the healthcare system in ways that could affect our ability to sell our products profitably. Among policy makers and payors in the United States and elsewhere, there is significant interest in promoting changes in healthcare systems with the stated goals of containing healthcare costs, improving quality or expanding access. Current and future legislative proposals to further reform healthcare or reduce healthcare costs may limit coverage of or lower reimbursement for the procedures associated with the use of our products. For example, on July 4, 2025, the One Big Beautiful Bill Act (the “OBBBA”) was signed into law, which narrowed access to ACA marketplace exchange enrollment and declined to extend the ACA enhanced advanced premium tax credits that expired at the end of 2025, which, among other provisions in the law, are anticipated to reduce the number of Americans with health insurance. The OBBBA also is expected to reduce Medicaid spending and enrollment by implementing work requirements for some beneficiaries, capping state-directed payments, reducing federal funding, and limiting provider taxes used to fund the program. Congress is considering proposed legislation intended to further reduce healthcare costs with alternatives to replace the expired ACA subsidies. The cost containment measures that payors and providers are instituting and the effect of any healthcare reform initiative implemented in the future could impact our revenue from the sale of our products.

The current administration is pursuing policies to reduce regulations and expenditures across government agencies including at HHS, the FDA, CMS and related agencies. These actions, presently directed by executive orders or memoranda from the Office of Management and Budget, may propose policy changes that create additional uncertainty for our business. For example, the current administration recently called on Congress to enact “The Great Healthcare Plan,” to codify and expand Most-Favored Nation pricing, lower government subsidies to private insurance companies and increase healthcare price transparency, among other things. Other recent actions, for example, include directing agencies to reduce agency workforce and cut programs. In June 2024, the U.S. Supreme Court’s Loper Bright decision greatly reduced judicial deference to regulatory agencies, which could increase successful legal challenges to federal regulations affecting our operations. Congress may introduce and ultimately pass health care related legislation that could impact the medical device approval process.

Coverage and Reimbursement

​In both U.S. and non-U.S. markets, our ability to successfully commercialize and achieve market acceptance of our products depends, in significant part, on the availability of adequate financial coverage and reimbursement from third-party payors, including governmental payors (such as the Medicare and Medicaid programs in the United States), managed care organizations and private health insurers. Reimbursement systems in international markets vary significantly by country and by region within some countries, and reimbursement approvals must be obtained on a country-by-country basis. In many international markets, a product must be approved for reimbursement before it can be approved for sale in that country. Further, many international markets have government-managed healthcare systems that control reimbursement for new devices and procedures. In most markets there are private insurance systems as well as government-managed systems. Should our products under development be cleared or approved for commercialization by the FDA, reimbursement may not be available in the United States or other countries, or the amount of reimbursement may not be sufficient to allow sales of our products on a profitable basis.

​Third-party payors are increasingly examining the cost effectiveness of products, in addition to their safety and efficacy, when making coverage and payment decisions. Third-party payors have also instituted initiatives to limit the growth of healthcare costs using, for example, price regulation or controls and competitive pricing programs. Some third-party payors also require demonstrated superiority, on the basis of randomized clinical trials, or pre-approval of coverage, for new or innovative devices or procedures before they will reimburse healthcare providers who use such devices or procedures. Additionally, no uniform policy for coverage and reimbursement exists in the United States, and coverage and reimbursement can differ significantly from payor to payor. Third-party payors often rely upon Medicare coverage policy and payment limitations in setting their own reimbursement rates, but also have their own methods and approval process apart from Medicare determinations.

​Coverage policies and third-party reimbursement rates may change at any time. Even if favorable coverage and reimbursement status is attained for procedures that utilize one or more products for which we might receive regulatory clearance and approval, less favorable coverage policies and reimbursement rates may be implemented in the future. It is uncertain whether our current products or any planned or future products will be viewed as sufficiently cost effective to warrant coverage and adequate reimbursement levels for procedures using such products.

Facilities, Manufacturing and Supply

​Our corporate headquarters and manufacturing, storage and distribution centers for our catheters and consoles are located at Laguna Hills, California. The facility is approximately 12,000 square feet, which includes clean room space and labs. We do not own any real property and believe that our current facilities are sufficient to support our operations and growth plans and that, additional space, if needed, will be available on commercially reasonably terms.

​Our manufacturing and distribution operations are subject to regulatory requirements of the European Medical Devices Regulations 2017/745 and amendments (“MDR”), for medical devices marketed in the European Union. When we begin marketing and distributing our products in the United States, we will be subject to the FDA’s Quality Management System Regulation (“QMSR”), set forth in 21 CFR part 820. Our Laguna Hills facility is certified to have established and is maintaining a quality management system pursuant to the requirements of the ISO 13485:2016 standard. In addition, the Laguna Hills facility is licensed by the California Department of Public Health Food and Drug Branch (“CDPH”). We are also subject to applicable local regulations relating to the environment, waste management and health and safety matters, including measures relating to the release, use, storage, treatment, transportation, discharge, disposal, sale, labeling, collection, recycling, treatment and remediation of hazardous substances.

​​TÜV SÜD Product Service GmbH (München, Germany) (“TÜV SÜD”) monitors our compliance with the MDR and ISO 13485:2016 requirements through annual scheduled audits and unannounced audits of the Laguna Hills facilities.

​Our failure, or the failure of our suppliers or third-party manufacturers, to maintain acceptable quality requirements could result in non-compliance of our manufacturing operations, which would harm our business. In the event that one of our suppliers or third-party manufacturers fails to maintain acceptable quality requirements, we may have to qualify a new supplier and could experience a material adverse effect to manufacturing and manufacturing delays as a result.

​We procure a broad range of the components and raw materials required for manufacturing of our catheters and consoles, including plastic and precious metals components and raw materials, complex electromechanical assemblies, electronic components and electronic assemblies. The identification and qualification of the suppliers is governed by the relevant provisions of our quality management system. As such, we can be materially adversely affected by disruptions in global supply chain, as well as inability of our suppliers to maintain required quality of the components and raw materials supplied to us, resulting in temporary hold or delay in manufacturing and distribution operations.

​We will pursue the opportunities for facility expansion as well as the transfer of the part or whole of the manufacturing operation to qualified third-party suppliers as warranted by business conditions.

Adagio Team

As of December 31, 2025, we had 41 full-time employees, located in the U.S. None of our employees are represented by a labor union or are a party to a collective bargaining agreement. We believe that the success of our business will depend, in part, on our ability to attract and retain qualified personnel. We have not experienced and do not expect any significant strikes or work stoppages and believe our relations with employees are in good standing.

Corporate Information

Adagio Medical Holdings, Inc., formerly known as Aja Holdco, Inc., was incorporated was incorporated as a Delaware corporation on December 19, 2023.

Our principal executive offices are located 26051 Merit Circle, Suite 102, Laguna Hills, California, 92653, and our telephone number is (949) 348-1188.

Availability of SEC Filings

We file annual reports on Form 10-K, quarterly reports on Form 10-Q, current reports on Form 8-K, and amendments to reports filed or furnished pursuant to Sections 13(a), 14, and 15(d) of the Securities and Exchange Act of 1934, as amended, or the Exchange Act. The SEC maintains a website at http://www.sec.gov that contains reports, and other information regarding us and other companies that file materials with the SEC electronically. Copies of our reports on Forms 10-K, Forms 10-Q, and Forms 8-K, may be obtained, free of charge, electronically through our corporate website at https://us.adagiomedical.com as soon as reasonably practicable after we file such material electronically with, or furnish to, the SEC.