The following discussion reflects the business of the Company. In this section, “we,” “our,” “the Company” or “QT Imaging” below generally refers to QT Imaging Holdings, Inc. and its subsidiaries.
Background of the Business Combination
On December 8, 2022, GigCapital5, Inc. (“GigCapital5”), our legal predecessor company and special purpose acquisition company, which was incorporated in Delaware in 2021, entered into a business combination agreement (“Business Combination Agreement”) with QTI Merger Sub, Inc., a subsidiary of GigCapital5 (“Merger Sub”) and QT Imaging, Inc. When the transactions contemplated under the Business Combination Agreement closed on March 4, 2024 (the “Business Combination”), Merger Sub merged with and into QT Imaging, Inc., with QT Imaging, Inc. the surviving company in the Business Combination, and after giving effect to the Business Combination, QT Imaging, Inc. became a wholly owned subsidiary of GigCapital5, which was renamed as QT Imaging Holdings, Inc.
QT Imaging, Inc. was incorporated in Delaware on December 31, 2020 by converting from its predecessor, QT Ultrasound LLC (“QT Ultrasound”), which was a limited liability company formed in 2012 to focus on the research, development, and commercialization of innovative body imaging systems using low energy sound. On that date, QT Imaging, Inc. changed its name from QT Ultrasound LLC to QT Imaging, Inc. and revoked the limited liability company election status by the incorporation.
QT Imaging Holdings, Inc. is headquartered in Novato, California.
A Novel Body Imaging Technology
The Company—with the support of nearly $181 million in financial support from the U.S. National Institutes of Health—has developed a novel, comprehensive body imaging technology that has high resolution, high sensitivity, high specificity, high positive and negative predictive values and is safe and inexpensive. The technology is based on ultra-low frequency transmitted sound and uses a one-of-a-kind novel sound back-scatter design and inverse-scattering reconstruction to create its images.
The Company is a medical device company founded in 2012 and engaged in the research, development, and commercialization of innovative body imaging systems using low energy sound. We believe that medical imaging is critical to the detection, diagnosis, and treatment of disease and that it should be safe, affordable and accessible. Our goal is to improve global health outcomes through the development and commercialization of imaging devices that address critical healthcare challenges with accuracy and precision.
The current standard of care for imaging in breast cancer screening, diagnosis, and treatment is far from satisfactory. Generally, the process starts with X-ray mammography, the primary screening tool for women. Mammography uses radiation, which in sufficient cumulative doses can increase the risk of cancer; is uncomfortable to painful for patients as it involves breast compression. Callbacks for adjunct screening and diagnosis include ultrasound, magnetic resonance imaging (“MRI”), and may include biopsies. This process is expensive, time consuming, and can be trying for women. Also, the use of three imaging modalities in the process speaks to the weakness of any one in adequately screening for breast cancer.
The Company’s opportunity in breast imaging is to speed the time to diagnosis for women with cancer, and to provide assurance for women who do not have the disease with a better patient experience and lower cost than the current standard of care.
The current QT Breast Scanner developed by the Company is a Class II device subject to premarket notification and clearance under Section 510(k) of the Federal Food, Drugs, and Cosmetics Act (“FDCA”). On August 23, 2016, QT Ultrasound submitted a Section 510(K) Summary of Safety and Effectiveness application for the QT Breast Scanner in accordance with 21 CFR 807.92 under 510(K) Number K162372. As part of meeting the general requirements for basic safety and essential performance of the QT Breast Scanner (formerly, QT Ultrasound Breast Scanner) pursuant to AAMI
1 This is comprised of previous grants including grants to the University of Utah ($811,000) and the current five year grant 1RO1CA273700 from the U.S. National Institute of Health for $2.58 million (Quantitative Ultrasound Monitoring of Breast Cancer Therapies), which was awarded to 3 institutions: University of Illinois, University of Toronto (Sunnybrook) and QT Imaging, which received $1.08 million of the $2.58 million grant.
ES60601-1:2005/(R)2012 and A1:2012 Medical electrical equipment, testing was conducted by Intertek, an independent testing laboratory, located in Menlo Park, CA. Intertek also conducted applicable testing pursuant to IEC 60601-1-6 Edition 3.1 2013-10-Medical electrical equipment Part 1-6 General requirements for safety—Collateral Standard: Usability. In addition, QT Ultrasound conducted, and Intertek witnessed, all applicable testing pertaining to the requirements for the safety of ultrasonic medical diagnostic and monitoring equipment and to demonstrate compliance with the “Acoustic Output Measurement Standard for Diagnostic Ultrasound Equipment”. This test on acoustic output was pursuant to IEC 60601-2-37 Edition 2.0.2007 Medical electrical equipment—Part 2-37: Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment. Finally, system verification testing was conducted to ensure that the QT Breast Scanner met all design and other requirements including but not limited to that no new issues of safety or effectiveness compared to the predicate device, SoftVue System manufactured by Delphinus Medical Technologies, were raised.
On June 6, 2017, the FDA, in response to the Company’s Section 510(K) Summary of Safety and Effectiveness premarket notification, determined that the QT Breast Scanner is substantially equivalent to the predicate device. Our use of the words “safe”, “safety”, “effectiveness”, and “efficacy” in relation to the QT Breast Scanner in this annual report and all other documents related to the Company is limited to the context of the Section 510(K) Summary of Safety and Effectiveness that was reviewed and responded to by the FDA.
The Cost and Accessibility of Healthcare
Medical imaging is an essential part of clinical diagnosis and is a requirement for making the best treatment decisions and improving a person’s health. Most people in the world live in low-resource environments and do not have access to advanced medical imaging—thus the absence of high-quality medical imaging in low resource environments (“LREs”) is a significant obstacle to providing basic health care.
Even in advanced health care facilities in the U.S., where adequate medical imaging is available, the cost of this medical imaging is very high—driving up healthcare costs and limiting accessibility to many people with limited income, high insurance deductibles or those in LREs or rural areas.
The Purpose of the Company
Most conventional imaging technologies—X-ray computed tomography (“CT”), MRI and positron-emission tomography (“PET”)—used in tertiary care require high energy, protective shielding of the patient, trained medical staff to operate the equipment, the administration of chemical agents to the patient to increase contrast and optimize visualization and specialized trained technicians to operate the equipment and ensure patient safety. Furthermore, the imaging procedures using these technologies are cumbersome, time-consuming and expensive. In addition, these conventional imaging technologies or modalities are not amenable to direct-to-consumer (“DTC”) or point-of-care (“POC”) settings or available in LRE. The Company believes that its new technology can address the issues presented by these conventional imaging technologies with its accurate, safe, less expensive and easily deployable imaging systems.
The Clinical Problem
The current medical imaging technologies—CT, MRI and PET—are commonly used in advanced health care facilities in North America, Europe, Japan and South Korea, with more limited deployment in selected tertiary care facilities in other countries—usually large urban areas. These current technologies are based on advanced engineering solutions that use high energy (X-rays, positrons or nuclear magnetic resonance signals) to see inside of the human body. These technologies require large capital investments, are limited to specialized facilities and require advanced certifications for the machines and their operators to insure safe operation. These machines are also expensive to purchase and maintain. All these factors combine to restrict their deployment to advanced clinical centers and tertiary care institutions.
A Solution to Increasing the Quality of Health Care and Lowering Costs
Advances in technology offer an opportunity to provide: 1) a means for obtaining better image quality in medical images, 2) access to DTC or direct to practitioner (“DTP”) medical imaging, 3) lower cost medical imaging, 4) reduced inconvenience and risk for patients by providing a safe alternative to high-energy imaging and 4) a lower cost solution for making a medical diagnosis. The Company believes that its technology is ideal for DTC, DTP and POC use because of its high performance, safety and relatively low cost. Furthermore, we believe that providing increased patient access to safe medical imaging is one important solution to increasing access and lowering the costs of medical care.
The Company intends to follow a staged entry into the market, beginning with clearances already in place which support its use as an adjunct to mammography and to monitor treatment. Additionally, the Company intends to pursue a regulatory and commercial pathway to support the use of its technology as an alternative to breast MRI in screening younger women (under 40 years of age) at above-average risk for breast cancer. In parallel, the Company will then use these placements as footholds from which to build presence in the medical community and acquire the data needed for additional FDA clearances and insurance reimbursement. In parallel with these efforts, the Company solidified existing business and distribution strategic partnerships to cover sales in US, as well as partnerships to build strong manufacturing processes to deliver the QT Breast Scanners in large scale production.
Our Competitive Strengths
We believe that our competitive strengths include the following:
The world-wide market for medical imaging is large and it has a potential to expand in the areas where the Company has differentiation;
a non-ionizing, non-contrast dye injection imaging modality;
an imaging modality with superior performance as compared to traditional mammogram with respect to specificity (false positive), thus less unnecessary emotional trauma for patients, reduced numbers of invasive follow-up procedures and a reduction of costs for both patient and broader society;
an imaging modality with the potential to offer superior specificity compared to screening breast MRI for younger women (under 40 years of age) at above-average risk. By reducing false positives, it holds the potential of sparing patients from undue emotional distress, limiting unnecessary biopsies and follow-up procedures, and ultimately decreasing healthcare costs for both individuals and society;
a lower price point than conventional high-energy imaging equipment;
the Company’s technology can be deployed to LREs because of its automation, small footprint, no shielding, no contrast-dye injection;
the Company’s technology is portable and can be used in POC settings such as LREs;
the Company’s technology is deployable in outdoor settings such as sports, military, and naval settings;
the Company’s technology reduces the barriers to testing and follow up-care for women, as there is no need for specialized training and the technology is well-suited for lowering health care costs by being affordable and easily accessed;
the Company’s technology provides optimized patient experience, as no radiation is involved, with the patient being able to be followed with no limitation to imaging frequency;
the Company’s technology is well-suited for traditional tertiary care hospitals and additionally for DTC and DTP applications, that are outside these institutions;
the Company’s technology is uniquely proprietary, disruptive and a one-of-a kind product that can address a variety of unmet medical needs in the medical marketplace;
the Company’s scanner features a uniquely simple design with a small number of components, which in turn significantly reduces the cost of the bill-of-materials (“BOM”), cost-of-good-sold (“COGS”), and the total-cost-of-ownership, and enables a lower average sales price (“ASP”) compared to other available systems, thus making it much more affordable to large mass deployments; and
the Company’s products have potential strong revenue growth, with capital purchase supporting substantial long-term gross margin.
Our Strategies
We believe that our strategies include the following:
Create disruptive technological innovation (software, artificial intelligence, and smart physics) to improve medical imaging and thus health care quality and access.
Continue to improve our high quality, high resolution, native 3D, reproducible image quality regardless of operator or breast size/tissue type breast imaging technology, as well as the techniques for quantifiable analysis, comparison, and training.
Partner with strategic business and distribution channels to address the U.S. market for breast imaging im-mediately and, other regions in the future, to place the QT Breast Scanner in hospitals, radiology centers, etc. and generate awareness of the benefits of the Company’s technology.
Perform small scale manufacturing internally to the Company and partner strategically for large scale manufacturing.
Expand the market by supporting additional DTC and DTP approaches to enable the ability to lower health care costs and increase access via personal medical imaging.
Provide a new social and economic opportunity for consumers to take control of some aspects of their own health care—such as imaging for minor injuries or medical conditions without needing a healthcare “gate-keeper.”
Focus our intellectual capabilities and ethical framework to become unified in our mission to improve the quality and lower the cost of health care world-wide... “It’s about time.”
Leverage on the intellectual property and know-how of the company as is demonstrated through the first family of QT Breast Scanner commercialization, to develop other scanning medical imaging products, such as infant scanners, full-body scanner and/or other products.
Industry & Market Opportunity
Doctors and hospitals are increasingly turning to medical imaging to screen for and diagnose cancer, support and monitor ongoing cancer treatment (drugs, radiation, and surgery), and offer non-invasive surgical options for patients. This has resulted in a major market opportunity—the annual worldwide medical imaging market currently is estimated to be $40 billion, with $10 billion coming from the United States.2 Global cancer screening, with an approximately $150 billion market size in 2022, is expected to grow at a compound annual growth (“CAGR”) of 12% and reach approximately $472 billion in 2033.3
Breast Imaging
Breast cancer detection and diagnostic technologies (including mammography, MRI, and ultrasound, as well as genetic testing and image guided breast biopsy) are a significant part of the medical imaging market and are estimated to represent a $4.6 billion global market in 2023 with an ongoing CAGR of 8%.4 The market is segmented by technology, primarily between ionizing breast imaging (e.g., mammography) and non-ionizing breast imaging, which includes ultrasound and MRI. The non-ionizing segment is expected to grow at a faster rate 5 than the ionizing segment due to technological advances such as better segmentation of anatomical detail, higher sensitivity to small breast lesions in women with dense breast tissue 6, and fewer false positives.
2 See, Fortune Business Insight, Medical Imaging Market Size, Share & COVID-19 Impact Analysis, Type (Magnetic Resonance Imaging, Computer Tomography, X-ray, Ultrasound, and Molecular Imaging), By Application (Cardiology, Neurology, Orthopedics, Gynecology, Oncology, and Others), by End User (Hospitals, Specialty Clinics, Diagnostic Imaging Centers, and Others), and Regional Forecast, 2021-2028 (Jan. 2022), available at https://www.fortunebusinessinsights.com/industry-reports/medical-imaging-equipment-market-100382.
3 See, Fortune Business Insight, Medical Imaging Market Size, Share & COVID-19 Impact Analysis, Type (Magnetic Resonance Imaging, Computer Tomography, X-ray, Ultrasound, and Molecular Imaging), By Application (Cardiology, Neurology, Orthopedics, Gynecology, Oncology, and Others), by End User (Hospitals, Specialty Clinics, Diagnostic Imaging Centers, and Others), and Regional Forecast, 2021-2028 (Jan. 2022), available at https://www.fortunebusinessinsights.com/industry-reports/medical-imaging-equipment-market-100382.
4 See, ReportLinker, Global Breast Imaging Technologies Market to Reach $5.8 Billion by 2030 (Feb. 2, 2023), available at https://finance.yahoo.com/news/global-breast-imaging-technologies-market-192600736.html?guccounter=1&guce_referrer=aHR0cHM6Ly9kdWNrZHVja2dvLmNvbS8&guce_referrer _sig=AQAAAJGTUiAxSng9741aF3B3-AT5uFrtLSoqRIo_b38QWPbYdAjvx0aejvhKoF-p3Yvh4jZ41GAPV6VDMPuYjtfUAHqMdEQhdA5buqzcGISJDID04pNvYySjQ92AlaTPNAa99CWcRem UxEbDmGEKPetyTskvCpwcWKRA8ZIWA_2Nb3mh.
5 See, GrandViewResearch, Magnetic Resonance Imaging Market Size, Share & Trends Analysis by Architecture, by Field Strength, by Application (Brain & Neurological, Vascular), by End Use, by Region, and Segment Forecasts, 2022-2030, available at https://www.grandviewresearch.com/industry-analysis/magnetic-resonance-imaging-market (last visited Feb. 10, 2023).
6 NIH, National Cancer Institute, Dense Breasts: Answers to Commonly Asked Questions (“Breasts contain glandular tissue, fibrous connective tissue, and fatty breast tissue. Breast density is a term that describes the relative amount of these different types of breast tissue as seen on a mammogram. Dense breast tissue has relatively high amounts of glandular tissue and fibrous connective tissue and relatively low amounts of fatty breast tissue.”), available at https://www.cancer.gov/types/breast/breast-changes/dense-breasts (Mar. 29, 2023).
The current standard of care for imaging in breast cancer screening, diagnosis, and treatment is far from satisfactory and may involve certain side effects. There are adverse effects to the use of medical imaging methods such as ionizing radiation, mammography, and MRI. Generally, the process starts with X-ray mammography, the primary screening tool for women. Mammography uses radiation, which in sufficient cumulative doses can increase the risk of cancer; and is uncomfortable or too painful for patients as it involves breast compression. Another adverse effect is the inefficiency of mammography in detection of cancer in women with dense breasts. There is a psychological adverse effect of callbacks for adjunct screening and diagnosis include ultrasound, MRI, and may include biopsies. This process is expensive, time consuming, and can be mentally and physically trying for women. Also, the use of three imaging modalities in the process speaks to the weakness of any one in adequately screening for breast cancer. MRI may take place in a closed environment which may cause claustrophobia, require sedation or general anesthesia and may require injection of a heavy-metal contrast agent. The use of sedation or anesthetic drugs risks severe compromise of respiratory and cardiac function.
Regarding CT, the harmful effects of radiation used in ionizing radiation exposure raises the risk of cancer, including leukemia, breast cancer, thyroid cancer and brain cancer. These issues make MRI preferred to CT for all but trauma evaluation.
The QT Breast Scanner has no reports of adverse effects from the more than 20,000 scans performed to date. Similar to other ultrasound devices, due to the low frequency and energy of those scanners, including handheld devices, there are no known significant risks reported in general clinical practice. The QT Breast Scanner does not require potentially harmful ionizing radiation or anesthesia and is done in an open environment thereby decreasing stress and the necessity of sedation. As a result, there is the potential for increased imaging efficacy. The QT Breast Scanner does not cause breast implant displacement or rupture.
The Company’s opportunity in breast imaging is to speed the time to diagnosis for women with cancer, and to provide assurance for women who do not have the disease with a better patient experience and lower cost than the current standard of care.
While the Company believes women will embrace its technology, the Company is focused on achieving clinical adoption through the medical community, which requires continuing research on the clinical efficacy of the images rendered by the QT Breast Scanner known as a QTscan® image and development of key opinion leaders (“KOLs”) who can speak to the clinical value of its machines in practice. In addition, the Company must navigate the economics and price controls of the U.S. reimbursement system, as well as the economics and price controls of any foreign country in which the Company’s products and product candidates may receive regulatory approval. The Company is also actively working to expand its regulatory clearances to support marketing the QT Breast Scanner as an alternative to breast MRI for screening, initially targeting above average-risk younger women and ultimately aiming to provide a screening option for all women. Finally, even given the achievement of all of these objectives, there must be a “critical mass” of installed scanners –patients must be able to access the machines.
There are three primary technologies within the non-ionizing breast imaging segment: Automated Breast Ultrasound Systems or ABUS; Breast Ultrasound Tomography Systems; and Photoacoustic Imaging.
Automated Breast Ultrasound Systems (“ABUS”)
The ABUS segment is the largest and is expected to grow at a CAGR of 16% worldwide over the next five years, with more than 2,000 installations in place and a market value of $850 million by 2024.7 This growth will be driven by the advantages inherent in ABUS: quick turnaround time, affordability of devices, ease of device deployment, accurate diagnostic results, and operations without continuous operator monitoring. In addition, contextual factors including rising health awareness, government advocacy for breast cancer awareness, and an increasing prevalence of breast cancer will contribute to the expansion of this market.
ABUS technologies typically use a reflection transducer 8 (5-15 MHz) and not transmitting setup, in a “motorized” arrangement. The major developers of such systems include: 1) the Acuson S2000 ABVS (sold by Siemens); 2) the Invenia System (s
7 See, MarketResearch, Automated Breast Ultrasound System Market Size Outlook in 2023 and Beyond: Market Trends, Insight, Growth Opportunities, Market Share and Forecasts by Types, Applications, Countries and Companies to 2023 (Feb. 2023), available at https://www.marketresearch.com/VPA-Research-v4245/Automated-Breast-Ultrasound-System-Size-33347813/.
8 A medical reflection transducer, also known as an ultrasound transducer, is a device that converts electrical energy into sound waves, and the back again into electrical energy. It is used in medical imaging to produce images of internal organs and tissues in the body, and it is used in various medical imaging techniques such as ultrasound, echocardiography and Doppler imaging. See, e.g., ECG & ECHO Learning, The Ultrasound Transducer, available at https://ecgwaves.com/topic/the-ultrasound-transmitter-probe/ (last visited Apr. 4, 2023); see also, FDA, Ultrasound Imaging Sept. 28, 2022), https://www.fda.gov/radiation-emitting-products/medical-imaging/ultrasound-imaging.
old by GE Healthcare); 3) a manual video loop AWBS System (sold by Sono-Cine); and 4) a motorized single transducer Sofia System (sold by Hitachi.). All of these systems produce B-mode reflection images 9.
Breast Ultrasound Tomography Systems
These technologies use traditional reflection transducers 10 in an “array” configuration around the breast: 1) Mastoscopia (Greece); 2) the KIT system (research only) from Karlsruhe University in Germany; and 3) the Delphinus System.
Photoacoustic Imaging
Photoacoustic imaging systems utilize lasers to excite tissues and produce acoustic energy that subsequently create images of the breast vasculature.11 Such systems include both photoacoustic tomography (“PAT”) and photoacoustic imaging (“PAI”) systems. While the PAT systems allow volumetric imaging by reconstructing stacks of 2D images, the PAI systems only allow superimposition of photoacoustic signal information on top of conventional B-mode ultrasound. Note that in comparison to ultrasound, photoacoustic imaging systems inherently lack the ability to image the tissue anatomy and essentially only image the vasculature (i.e., blood, which is a strong absorber of light). For PAT systems, there is no clinical trial data available (to our knowledge) and no PAT systems have been approved for clinical use. For PAI systems, the Imagio Breast Imaging has been used in clinical trials and is FDA cleared to be used as an adjunct to conventional handheld breast ultrasound.
All of these technologies face challenges to expansion, including FDA clearances and insurance reimbursement. However, the shortcomings of other imaging methods such as ionized radiation exposure, high costs and deployment challenges of MRI, and the inefficiency of mammography in detection of cancer in women with dense breasts, are sufficiently compelling for industry to address these obstacles, and these shortcomings will continue to create an opportunity for development and commercialization of advanced screening systems such as the Company’s.
To our knowledge at the time of filing this annual report, we are not aware of any technologies approved for primary screening clearance by the FDA except for various types of technology related to X-ray mammography.
Future Market Opportunities
While the Company’s short-to-medium term focus will be on breast scanning, future products will open additional markets. The Company’s Open Partial Angle Scanner concept, which is currently under development, is expected to provide entry into the global orthopedic medical imaging market, which is estimated to be $7.3 billion by 202512.
9 B-mode ultrasound, also known as 2D ultrasound, is a type of ultrasound imaging where “a linear array of transducers simultaneously scans a plane through the body that can be viewed as a two-dimensional image on screen.” See, NIH, National Library of Medicine, Carovac A., Smajlovic F., Junuzovic D., Application of Ultrasound in Medicine, 19(3) Acta Inform Med. 168-171 (Sept. 2011), available at https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3564184/.
10 Medical reflection transducer, also known as an ultrasound transducer, is a device that converts electrical energy into sound waves, and the back again into electrical energy. It is used in medical imaging to produce images of internal organs and tissues in the body, and it is used in various medical imaging techniques such as ultrasound, echocardiography and Doppler imaging. See, e.g., ECG & ECHO Learning, The Ultrasound Transducer, available at https://ecgwaves.com/topic/the-ultrasound-transmitter-probe/ (last visited Apr. 4, 2023); see also, FDA, Ultrasound Imaging Sept. 28, 2022), https://www.fda.gov/radiation-emitting-products/medical-imaging/ultrasound-imaging.
11 Breast vasculature refers to the blood vessels that supply and drain blood from the breast tissue. The breast is a highly vascularized organ, and the blood supply comes from a network of arteries and veins that run throughout the breast tissue. See, NIH, National Library of Medicine, Yusuf S. Khan, Hussain Sajjad, Anatomy, Thorax, Mammary Gland, available at https://www.ncbi.nlm.nih.gov/books/NBK547666/ (last updated July 25, 2022).
12 See, MarketWatch, Orthopedic Medical Imaging Market Size Analysis between Two International Players through Business Aspects Way 2026 (Feb. 6, 2023), available at https://www.marketwatch.com/press -release/orthopedic-medical-imaging-market-size-analysis-between-top-international-players-through -business-aspects-way-2026-2023-02-06.
Company’s Products & Product Road Map
Current Products
Proposed Products Under Development
QT Breast Scanner
The Need: A safe, painless imaging device that provides conclusive breast health assessment
Breast cancer is the most commonly diagnosed women’s cancer in the United States, according to the National Cancer Institute. The American Cancer Society estimates that in 2022, 287,850 women in the United States have been diagnosed with invasive and in situ (early stage) breast cancer, and breast cancer has claimed the lives of 40,920 women.13 The American Cancer Society further estimates that one out of every eight women will develop breast cancer at some point during her life and one in every 42 women who turns 50 today will have a diagnosis of breast cancer before she turns 60.
There are several dominant screening and diagnostic technologies that are used both independently and dependently to locate cancers at an early stage and improve treatment outcomes. Each of the currently available non-surgical modalities for breast cancer detection has various clinical limitations. Screening methods and technologies include: (i) breast self-
13 See, American Cancer Society, Breast Cancer Facts & Figures, available at https://www.cancer.org/research/cancer-facts-statistics/breast-cancer-facts-figures.html (last visited Feb. 10, 2023).
examination and clinical breast examination; (ii) mammography, including screening mammography, diagnostic mammography, and mammography with computer aided detection; (iii) Hand-Held Ultrasound (“HHUS”) and (iv) MRI.
Mammography is the dominant imaging modality in today’s standard of care. The American Cancer Society recommends that women of average risk have the option to begin mammography at age 40, get mammograms every year from age 45-54, and have mammography every other year starting at age 55.14 Despite those recommendations, only 65% of women over 40 in the United States have had a mammogram in the previous two years, and only 58% of women between 40 and 49 had a mammogram in the previous two years,15 even though screening mammography is 100% covered under the Affordable Care Act. This is in part due to the limitations of mammography, both in terms of sensitivity and reliability for dense breast tissue, where 10-15% of cases have inconclusive results requiring further testing, as well as concerns about safety. Mammography is also problematic in women who have breast implants. For these women, problems include painful mammograms, delayed detection of cancer from interference in imaging breast tissue, and an unwillingness to perform mammograms due to fear of implant rupture, dislocation or capsular contracture.
The Company’s goal is to provide highly accurate, 100% safe, radiation-free and painless breast imaging that can be used to:
1)identify cancer early to minimize invasiveness and increase effectiveness of treatment; and
2)eliminate unnecessary intervention (additional imaging and biopsies) for women with benign breast conditions, most notably cysts.
The Product, QT Breast Scanner
The QT Breast Scanner is a fixed, stationary, mechanical scanner used to evaluate the breast without the use of either ionizing radiation or compression associated with mammography, or the injections required for breast MRI. With the QT Breast Scanner, the patient lies comfortably on a table which contains an opening through which the breast is immersed in a warm water bath (see Image 1) and gently immobilized using a magnetic retention pad fixed to a magnetic rod.
The QT Breast Scanner
Image 1
Surrounding the warm water bath is a dual modality reflection and transmission ultrasound array that rotates 360 degrees around the breast (see Image 2 & Image 3) to produce 3D images. The ultrasound array produces low energy, low frequency sound waves (non-radiation “pressure waves”) through the breast and reflecting from the breast, with both collecting volumetric (3D) data. Reflection data is collected on the transducer facing side, and the transmission data is collected on the back side of the breast. The transmission data quantitatively measures the velocity of these pressure waves through the breast. This information can be used to generate a true 3D image of the breast and all its tissues. The QT Breast Scanner differs from the handheld ultrasound used in breast imaging in that it utilizes reflection and transmission data from low-frequency sound waves, providing a significant increase in diagnostic information using the speed of sound characteristics of the breast and acquiring in true 3D a very accurate rendering of the breast tissue. The QT Breast Scanner provides sub-millimeter, high-definition, image resolution enabling identification of normal and abnormal breast structures and the accurate depiction of the precise shape and location of findings. The technology uniquely quantifies breast density using transmission information to further personalize a patient’s management recommendations. Surface-to-volume ratios
14 See, American Cancer Society, American Cancer Society Recommendations for the Early Detection of Breast Cancer, available at https://www.cancer.org/content/cancer/en/research/infographics-gallery/breast-cancer-screening-guideline.html (last visited Feb. 10, 2023).
15 U.S. Department of Health and Human Services, “Health, United States, 2016”, Table 70.
and volumetric doubling time growth rate characteristics can be calculated to determine significance of lesions and improve specificity of the ultrasound.
| The transducer array in the water bathImage 2 | Schematic of rotating ultrasound transmitterImage 3 |
|---|
The QT Breast Scanner creates true 3D images of the patient’s breast viewable in the Quantitative Transmission Ultrasound Viewer (known as QTviewer®), a software product designed for healthcare professionals to view the transmission (speed of sound) and reflection images. This application can display correlated Digital Imaging and Communications in Medicine (“DICOM®”) images in multiple orientations (coronal, sagittal, and axial). QTviewer can manipulate image views and analyze pixel data with various functions. The QTviewer has additional functionality which enables the user to measure mass size and volume as well as fibroglandular tissue volume.16
Image 4 below is a still image of the viewer for a patient with a cyst. The transmission (top 3 panels) and reflection (bottom 3 panels) images as seen in coronal, axial, and sagittal representations.
Image 4
The QT Breast Scanner is the current version of the QT Breast Scanner and is FDA-cleared “for use as an ultrasonic imaging system to provide reflection-mode and transmission-mode images of a patient’s breast. The device is not intended to be used as a replacement for screening mammography.”17
16 See, American Association for Cancer Research, R. Natesan, J. Wiskin, S. Lee, B. H. Malik, Quantitative Assessment of Breast Density: Transmission Ultrasound is Comparable to Mammography with Tomosynthesis (Dec. 3, 2019), available at https://aacrjournals.org/cancerpreventionresearch/article/12/12/871/47203/Quantitative-Assessment-of-Breast-Density.
17 U.S Department of Health and Human Services, Food and Drug Administration, 510(k) number K162372.
The QT Breast Scanner has current applicability as a supplementary imaging device (not as a replacement for screening mammography); near-term applicability for determining breast density, measuring mass size and growth, and diagnosing lesions using artificial intelligence; and medium- to long-term applicability for breast screening as shown in Table 1.
| Use of the QT Breast Scanner | Value it Adds | QT Timeframe* |
|---|---|---|
| Supplementary imaging | Adjunct to screening mammography (not a replacement), particularly for women with dense breasts to identify masses missed by mammography or provide additional information on masses seen, with the potential to reduce unnecessary procedures | Current |
| Fibroglandular Tissue Volume & the Ratio of Fibroglandular Tissue Volume to Total Breast Volume | Ability to quantify this ratio (a risk factor for breast cancer), without compression or radiation of mammography | Current |
| Mass Size and Growth | Ability to measure response to treatment and assess mass stability | Short term |
| A.I.-Based Mass Diagnostics | Reduce unnecessary procedures (biopsies, additional imaging) by identifying lesion type | Short term |
| Screening for High-Risk Young Women | Provide young women a safe, comfortable, accurate method to screen for breast cancer, as an alternative for breast MRI | Medium term |
*Note: the foregoing is based on the Company’s current estimates and the timeframe is subject to change due to various factors, including those described in the “Risk Factors” section and elsewhere in this annual report.
Breast Scanner Clinical Images
The images below (Image 5 and Image 6) compare an artist’s depiction of the normal breast anatomic features (top) and QTscan® images rendered by the QT Breast Scanner of a normal human breast (below) showing the skin, fat, breast duct and glandular (terminal) units of the living breast. The Cooper’s ligaments, ducts, and glandular structures are not visible in conventional breast screening imaging.
Schematic anatomy of the breast
Image 5
Transmission (left) and reflection tomograms of the breast. The white and black squares in the speed of sound image (left) mark fat and glandular tissue, respectively. Single and double black arrows mark ductal tissue and skin, respectively. Reflection image (right): Single white arrows mark the connective tissue identified as Cooper’s ligaments.
Image 6
Two key metrics in breast imaging are sensitivity and specificity. Mammography has well-recognized challenges with sensitivity in dense breasts. Image 7 below compares the same breast across different imaging modalities. In addition to demonstrating differences in image quality across modalities, it represents a case where a mass was not visible on mammography but is visible on the MRI and QTscan.
Image 7
The Company recently conducted a mini study looking specifically at the ability of its technology to identify masses in dense breasts compared to mammography. Forty cases were selected in which there was a finding on the QTscan. The cases were selected from a “Case Collection Study to Determine the Accuracy, Call Back and Cancer Detection Rates of QT Ultrasound in Breast Imaging (ACCRUE)” sponsored by QT Ultrasound LLC. This is available at ClinicalTrials.gov Identifier: NCT03052166. Two cases were subsequently excluded as there was not a corresponding mammogram, leaving 38 cases for comparison. The ACCRUE study was a prospective, multicenter, multi-arm case collection study which followed an adaptive design with an initially planned total enrollment of approximately 600 cases to include both benign and malignant cases, representative of all tissue densities. The study type was observational with an actual enrolment of 755 participants starting in April 2017. The end date was initial December 31, 2019, but actual completion date was January 1, 2020. There were three cohort groups: Cohort A-The group of asymptomatic subjects who have been given BI-RADS 1 or 2 based on their most recent standard of care assessment. All subjects received a QT Ultrasound scan. Cohort B-The group of asymptomatic women who have been given BIRADS categories 4 or 4a, 4b, 4c or 5 based on their most recent standard of care assessment. All subjects received a QT Ultrasound scan. Cohort C -The group of women who have been given BI-RADS categories 1, 2, 3, 4 or (4a, 4b, 4c), 5 or 6 based on their most recent standard of care assessment. All subjects received a QT Ultrasound scan. Subjects are assigned to Cohort C when it has been determined they cannot be assigned to Cohort A or Cohort B. The mammograms were interpreted by board-certified breast radiologists. In 32 of those cases, abnormalities identified using the QTscan were not identified on the mammogram. Image 8 (following) is one of those cases, where a solid mass was identified on the QTscan but not visible on the mammogram. The scope, size and design of these clinical studies are conducted in accordance with the provisions of the International Conference on Harmonization Guidelines for Good Clinical Practice and the Declaration of Helsinki. In some instances, the Company or one of its affiliates sponsored or designed the clinical studies and the Company’s employees analyzed or authored the results, findings, or articles. This was an exploratory study of limited scope in order to determine if further studies were warranted. The study was not powered for statistical analysis, but provided information to support a broader study. The full studies are available at www.qtultrasound.com/dense-breast-mass/.
Example of a QTscan mass (right) not seen on x-ray mammography (left)
Image 8
Some of the following additional studies were not conducted by the Company or specifically related to the QTscan. However, the Company or one of its affiliates sponsored or designed the clinical studies or the Company’s employees analyzed or authored the results, findings, or articles which are generally applicable to the Company or the QTscan.
- M.P. Andre, C Barker, N Sekhon, J Wiskin, D Borup, K. Callahan: Pre-clinical experience with full-wave inverse scattering for breast imaging: Sound speed sensitivity, Acoustical Imaging 29:73-80, Springer, Dordrecht, 2009.
The Andreet al study was a pilot clinical study not conducted by the Company and there is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- J. Wiskin; D. Borup; S. Johnson; M. Berggren; D. Robinson; J. Smith; J. Chen; Y. Parisky; John Klock, ‘Inverse scattering and refraction corrected reflection for breast cancer imaging’, Jan D’hooge; Stephen A. McAleavey, Eds., Proc. SPIE, 7629, 2010.
The Wiskinet al study was a pilot clinical study involving the participation of Dr. Klock. There is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- Pellegretti, P, S Dellepiane, M. Vicari, M. Zani, M. Weigel, D. Borup, J. Wiskin, U. Saueressig, E. Kotter, and M. Langer AClinical Experience of a Prototype Automated Breast Ultrasound System Combining Transmission and Reflection 3D Imaging, UFFC 2011-IEEE International Ultasonics Symposium Oct. 18-21, 2011, Session P3Ab, b Tomography.
The Pellegrettiet al study was a pilot clinical study not conducted by the Company and there is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- Andre, M. PhD, James Wiskin, PhD, Haydee Ojeda-Fournier, MD, Linda Olson, MD, David Borup, PhD, Melissa Ledgerwood, B.S., Steven Johnson, PhD, “Quantitative 3D Whole Breast Imaging with Transmission and Reflection Ultrasound” AAPM Ultrasound Imaging Symposium Breast Imaging and Guidance of Interventions
This Andreet al study was a pilot clinical study not conducted by the Company and there is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- J. Wiskin, D. Borup, K. Callahan, Y. Parisky, J. Smith, M. André, S. Johnson, Inverse scattering Results, Acoustical Imaging 30, pp. 61-68, Springer, Dordrecht, 2011.
This Wiskinet al study was a pilot clinical study not conducted by the Company and there is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- Andre, M, J. Wiskin et al., AIUM Annual Convention, New York, 2011, “Quantitative 3-Dimensional Whole-Breast Imaging With Transmission and Reflection Ultrasound”, Advanced Breast Imaging Symposium, Moderators: M. Andre and P. Carson, Ph.D.
This Andreet al study was a pilot clinical study not conducted by the Company and there is no comparator. The number of participants was fewer than 20. This was a registry study not a comparative trial. There were no serious adverse events and no statistical analysis was needed, since there was no comparator.
- John C. Klock, Elaine Iuanow, Bilal Malik, Nancy A. Obuchowski, James Wiskin, and Mark Lenox. Anatomy-Correlated Breast Imaging and Visual Grading Analysis Using Quantitative Transmission Ultrasound. International Journal of Biomedical Imaging Volume 2016, Article ID 7570406, 9 pages http://dx.doi.org/10.1155/2016/7570406
This Klocket al study was a comparative clinical study of QT Breast Imaging vs standard X-ray mammography done at the request of the FDA, therefore it was not a clinical outcome study. The number of participants was fewer than 20. All images were anonymized. This was a registry study not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one requested by the FDA to see the trends-analysis of the QT versus the Mammography in identifying structures in the breast.
- Bilal Malik Ph.D.*, John Klock M.D., James Wiskin Ph.D., and Mark Lenox Ph.D. Objective breast tissue image classification using Quantitative Transmission ultrasound tomography. Nature Sci. Rep. 6, 38857; doi: 10.1038/srep38857 (2016). https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5146962/
This Maliket al study was a comparative clinical study of the Company vs standard tissue pathological analysis to determine the precise structure/image correlations of QT Breast Imaging. The study was not a clinical outcome study. The number of participants was fewer than 20. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images.
- Elaine Iuanow, MD, Kathleen Smith, MBA, Nancy A. Obuchowski PhD†, Jennifer Bullen MS† and John C. Klock, MD. Accuracy of Cyst vs. Solid Diagnosis in the Breast Using Quantitative Transmission (QT) Ultrasound. Academic Radiology 2017 Vol 24:1148-1153; doi: 10.1016/j.acra.2017.03.024. Epub 2017 May 23; PubMed ID 28549870. Academic Radiology has posted the study in full for free. http://www.healthimaging.com/topics/womens-health/breast-imaging/and-coming-ultrasound-technology-shows-prowess-mammography-adjunct.
This Iuanowet al study was a comparative clinical study of the Company vs standard tissue biopsy analysis to validate the structure/image correlations of QT Breast Imaging, therefore it was not a clinical outcome study. The number of participants was fewer than 20. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images.
- John C Klock, Elaine Iuanow, Kathleen Smith, Nancy A and Obuchowski Visual Grading Assessment of Quantitative Transmission Ultrasound Compared to Digital X-ray Mammography and Hand-held Ultrasound in Identifying Ten Breast Anatomical Structures. BAOJ Clinical Trials 3: 015. (2017). https://bioaccent.org/clinical-trials/clinical-trials15.pdf
This Klocket al study was a comparative clinical study of QT Breast Imaging vs standard X-ray mammography and breast examination using handheld ultrasound done at the request of the FDA, therefore it was not a clinical outcome study. The number of participants was fewer than 20. All images were anonymized. This was a registry study not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one requested by the FDA to see the trends-analysis of the QT versus the Mammography in identifying structures in the breast.
- Bilal Malik, Alyson Terry, John Klock and Mark Lenox. Sensitivity of Quantitative Transmission ultrasound to detection of microcalcifications. SPIE (International Society for Optics and Photonics) Meeting Houston Texas February 20, 2018.
This Maliket al study was a pilot clinical study involving the participation of Dr. Klock. There is no comparator. The number of participants was fewer than 20. All images were anonymized. This was a registry study not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one requested by the FDA to see the trends-analysis of the QT versus the Mammography in identifying structures in the breast.
- Malik B, Klock JC. Breast Cyst Fluid Analysis Correlations with Speed of Sound Using Transmission Ultrasound , Academic Radiology 26:76-85, Jan 2019 https://www.sciencedirect.com/science/article/pii/S1076633218301788
This Maliket al study was a comparative clinical study of the Company vs standard tissue biopsy chemical and cytological analysis to validate the structure/image correlations of QT Breast Imaging, therefore it was not a clinical outcome study. The number of participants was fewer than 20. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images.
- J Wiskin, B Malik, R Natesan, M Lenox. Quantitative Assessment of Breast Density Using Transmission Ultrasound Tomogaphy. Medical Physics VolXXX https://doi.org/10.1002/mp.13503
This Wiskinet al study was a comparative clinical study of the Company vs standard breast density measurements using X-ray mammography to validate the software used to determine breast fibroglandular volumes in women. It was not a clinical outcome study. The number of participants was fewer than 30. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images.
- Natesan R, Wiskin JW, Lee S, Malik B. Quantitative assessment of breast density: transmission ultrasound is comparable to mammography with tomosynthesis. Cancer Prevention Research 12:871-826 2019. Doi: 10.1158/1940-6207.CAPR-19-068 https://cancerpreventionresearch.aacrjournals.org/content/early/2019/10/23/1940-6207.CAPR-19-0268
This Natesanet al study was a comparative clinical study of the Company vs standard breast density measurements using X-ray mammography to validate the software used to determine breast fibroglandular volumes in women. It was not a clinical outcome study. The number of participants was fewer than 50. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and the statistical analysis was a Pearson Correlation Coefficient of QT fibroglandular volume versus the Volpara breast volume as shown below:
- Wiskin, J., Malik, B., Borup, D. et al. Full wave 3D inverse scattering transmission ultrasound tomography in the presence of high contrast. Sci Rep 10, 20166 (2020). https://doi.org/10.1038/s41598-020-76754-3.
This Wiskinet al study was a comparative clinical study of the Company vs standard MRI imaging of human knees. to validate the performance of the Company to standard orthopedic MRI imaging. It was not a clinical outcome study. The number of participants was fewer than 30. All images were anonymized. This was not a comparative outcome trial of patient results. There were no serious adverse events and no statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images.
- Wiskin J, Malik B, Ruoff C, Pirshaffiey N, Klock J. Whole body imaging using low frequency transmission ultrasound. Academic Radiology 2023 https://www.academicradiology.org/article/S1076-6332(23)00033-8/fulltext.
This Wiskinet al study was a comparative clinical study of the Company vs standard 3-Tesla MRI imaging of 4 neonatal piglets as surrogates for human newborn infants. This study was done to validate the performance of the Company to standard MRI imaging. It was not a clinical outcome study. This was a piglet study. No statistical analysis was needed, since the study was a simple one to determine tissue pathology correlations with the QT images and with MRI images.
- Bilal Malik, PhD, Elaine Iuanow, MD, John Klock, MD. An Exploratory Multi-reader, Multi-case Study Comparing Transmission Ultrasound to Mammography on Recall Rates and Detection Rates for Breast Cancer Lesions. Academic Radiology Vol 29 – Supplement 1 S10-S18, Jan 1, 2022. doi:https://doi.org/10.1016/j.acra.2020.11.0.11 and https://www.academicradiology.org/article/S1076-6332(20)30646-2/fulltext
In this Maliket al study, three-dimensional Quantitative Transmission (“QT”) ultrasound imaging was used for the detection and diagnosis of breast cancer. QT ultrasound has high resolution and high contrast to noise ratio, making it effective in evaluating breast tissue. This study compared radiologists’ performance of noncancer recall rates and lesion detection rates using QT Ultrasound versus full-field digital mammography (“FFDM”) in a cross section of female subjects. In this multi-reader multi-case (“MRMC”) study, we examined retrospective data from two clinical trials conducted at five sites. All subjects received FFDM and QT scans within 90 days. Data were analyzed in a reader study with full factorial design involving 22 radiologists and 108 breast cases (42 normal, 39 pathology-confirmed benign, and 27 pathology-confirmed cancer cases). The main results used a random-reader random-case analysis adjusted for location bias performed after a primary predefined random-reader fixed-case analysis. The readers’ mean rate of detecting lesions of any type was 4% higher (p-value > 0.05) with the Company. The mean non-cancer recall rate improved significantly, showing a decrease of 16% with QT (p-value > 0.03), at the expense of a 2% decrease in the mean cancer recall rate (p-value > 0.05) in comparison to FFDM. Combining performance on cancer and noncancer recall rates, the mean area under the receiver operator curve of confidence scores improved significantly by 10% with QT (p-value = 0.01). This MRMC study indicated that QTscan improves non-cancer recall rates without substantially affecting cancer recall rates.
STATISTICAL ANALYSIS—The data were analyzed for the entire cohort of 108 breast cases (42 normal, 39 pathology-confirmed benign, and 27 pathology-confirmed cancer cases) using two general approaches: a random-reader fixed-cases (“RRFC”) analysis and a random-readers random cases (“RRRC”) analysis. RRFC analysis generalizes to the population of readers, but is specific to the particular case set and is termed random-reader fixed-cases analysis. In comparison, RRRC analysis generalizes both the case set and the population of readers. The RRRC analysis was expected to provide results more generalizable to new readers reading new cases, but with wider confidence levels compared to the RRFC analysis.
For both approaches, performance comparisons between QT and FFDM were summarized in terms of mean differences between readers and 95% confidence intervals (“CI”) for these differences with p-values determining the degree of statistical significance. The performance metrics included non-cancer and cancer recall rates and detection rates for all lesions. In addition, the study analyzed the mean area under the receiver operator curve (“ROC-AUC”) based on the readers’ confidence scores as a statistically efficient approach to evaluating the cancer and noncancer performance metrics combined into a single measurement. These analyses were performed according to the method of Obuchowski & Rockette with Hillis adjustment to the degrees of freedom. The RRRC analysis of ROC-AUC was performed with the software package ORDBM MRMC 2.5, written by Stephen L, Kevin M. Schwartz, and Kevin S. Berbaum. The trapezoidal/Wilcoxon method for curve fitting and jackknifing for the covariance estimation were used in the analysis. All other statistical analyses were performed in the statistical computing environment R version 3.4.0 or higher. No statistical adjustments were made for multiple analyses. The ground truth was established by one-year follow-up mammogram results for the normal cases and pathology results for the benign and cancer cases. All RRFC and RRRC results were adjusted post-hoc for location bias, considering recalls as correct only when the decisions were based on the correct ground-truth lesions. This adjustment is indicated because the severity of location bias is dissimilar for the two imaging modalities. Therefore, the study was adjusted for location bias to avoid favoring the modality with higher false-positive rates.
Leveraging the speed of sound attribute of transmission ultrasound, the QTscan offers advantages in specificity as well. Image 9 below compares the same breast on mammography and the QTscan. While the mass may be visible in mammography, mammography cannot be specific about whether the mass is malignant or benign. The QTscan identifies the mass as a benign cyst based on speed of sound as well as morphology.18
Example of a cyst visible on the QTscan (right) not sees on x-ray mammography (left)
Image 9
18 See, HealthImaging, Up-and-coming Ultrasound Technology Shows Prowess as Mammography Adjunct (May 24, 2017), available at https://healthimaging.com/topics/medical-imaging/womens-imaging/and-coming-ultrasound-technology-shows-prowess-mammography (providing a link to Academic Radiology, through which the study is accessible free of charge at https://www.academicradiology.org/article/S1076-6332(17)30207-6/fulltext).
Image 10 below is a case of lobular carcinoma. As with the previous cases, note that the QTscan offers comparable image quality and diagnostic information as an MRI, but without the high cost associated with MRI or patient experience issues associated with claustrophobia, radition or injection.
Example of a cancer not seen on x-ray mammography (far left), hand-held ultrasound (middle left) and non-enhancing on MRI with gadolinium injection (middle right) is clearly visible in the QTscan (far right).
Image 10
While the preceding cases describe and demonstrate certain advantages of the QTscan, due to limitations in print quality, case studies are best viewed on a high-quality monitor. Please visit the Company’s website to view additional case studies and image comparisons—https://www.qtimaging.com/casestudies/.
Comparison of the QT Breast Scanner with currently available devices 19
19 A medical device articulating arm is a mechanical arm or support structure used in medical procedures to position or hold surgical instruments, cameras, or other medical equipment. The arm typically consists of several articulated segments or joints that can be adjusted and locked in place to achieve a specific position or orientation. Medical device articulating arms are commonly used in minimally invasive surgeries, such as laparoscopy or endoscopy, where precise control and positioning of instruments are essential for successful outcomes.
There are several differences between the QT Breast Scanner and HHUS, ABUS, BUST, PAI, and PAT devices.
Other devices use Piezo-electric transducers that provide primarily “B-mode” poor resolution data. There is no valid true “transmission mode” since they use shear wave. Their images have reflection and compounding artifacts. Furthermore, their images are compounded 2D slices and they do not acquire the data in 3D. The resolution of their “3D” mode, “speed” images and specificity for masses is poor and their contrast-to-noise ratios are low. Their images cannot differentiate calcifications so in our opinion at least 20% of all cancers, mainly DCIS and non-invasive cancers, are missed. They have no “functional” imaging features such as doubling time to diagnose slow-growing cancers, tissue identification and specific tissue volume segmentations. There is poor reproducibility of their measurement and volume data thus they cannot follow cancer treatments or do breast density measurements.
Very few companies undertake or sponsor comparative clinical trials and what data is produced lacks clinical usefulness in terms of sensitivity and specificity. Other than Delphinus’ secondary screening trial that we are aware of, many companies have failed to do head-to-head trials against mammography for primary screening. In their current iterations their technologies are not able to do body or orthopedic imaging for future growth and development.
Of critical importance in comparing the Company’s devices against other devices are factors such as their lack of FDA clearances for general screening, their lack of comparative trials for primary breast cancer screening, and the fact that their clinical resolution, presence of artifacts, and sensitivity and specificity data are not clinically useful.
Description of Future Products and Services
The Company believes that its Open Partial Angle Scanner concept, under development, will provide entry into the global orthopedic and infant medical imaging markets as described below. The following discussion and description of product candidates and their respective potential applications and uses is a discussion of the Company’s future products and product candidates, all of which are still in development stages and the Company can provide no assurance regarding when, if ever, these products and product candidates may be brought to market, or when, if ever, the Company would seek FDA premarket clearance or approval of a PMA application. As such, the discussion below contains information that is forward-looking in nature and investors are cautioned not to place undue reliance on these forward-looking statements.
Proposed QT Orthopedic Scanner
The Need—In-office orthopedic and extremity imaging joint and internal soft tissue diagnosis
The Company believes musculoskeletal conditions are the most common reasons for doctor visits, lost productivity, and disability in the United States. Among these, arthritis (osteoarthritis and rheumatoid arthritis) and back or spinal problems are the first and second leading causes of disability among adults. As the U.S. adult population ages, the prevalence of these conditions appears to be increasing, resulting in concomitant increases in healthcare resource utilization. According to the American Productivity Audit, pain of musculoskeletal origin (including back-pain, arthritis-related pain, and pain due to other musculoskeletal conditions) was reported by 7.2% of the workforce as having occurred over the previous two weeks.20 The knee is the most commonly injured joint by adolescent athletes with an estimated 2.5 million sports-related injuries presenting to emergency departments (“EDs”) annually.21 Additionally, there are more than one million joint replacements per year in the U.S. with over 790,000 knee replacements done by physicians.
The differential diagnosis of nonspecific musculoskeletal complaints is challenging, and the use of imaging modalities is often required to establish a diagnosis, guide treatment, or monitor disease progression. MRI is a widely used medical technology and is often employed as the preferred imaging tool for disorders of the musculoskeletal system, as it can better delineate soft tissue structures than either plain X rays or CT despite being costlier and having a longer procedural time
20 See, JAMA, Lost Productive Time and Cost Due to Common Pain Conditions in the U.S. Workforce (Nov. 12, 2003), available at https://jamanetwork.com/journals/jama/fullarticle/197628.
21 See, American College of Rheumatology, Joint Replacement Surgery, available at https://www.rheumatology.org/I-Am-A/Patient-Caregiver/Treatments/Joint-Replacement-Surgery#:~:text=Approximately%20790%2C000%20total%20knee%20replacements,in%20any%20area %20of%20medicine (last visited Feb. 10, 2023).
compared with CT. Currently there is no optimal imaging technology for imaging implanted orthopedic prosthetic devices. MRI and CT scanners produce confounding artifacts that make these devices less than satisfactory for this application. As previously discussed, CT employs ionizing radiation and MRI frequently requires heavy-metal injection. In addition, the closed environment of an MRI is challenging for many patients and intolerable for others.
Ultrasonography is a noninvasive imaging modality used for the assessment of the musculoskeletal system. It can provide clinically useful information on a wide range of pathologic conditions affecting components of the knee joint, including the tendons, ligaments, muscles, synovial space, articular cartilage, and surrounding soft tissues. Color and power Doppler techniques can be used to measure neovascularization within the synovial lining of the joints, tendons, and soft-tissue masses. The advantages of ultrasound include low cost, portability, real-time assessment, no radiation and facilitated side-by-side comparisons. Its major disadvantage is its operator-dependence: it requires trained experienced hands with appropriate high-resolution equipment. Ultrasound examinations of the knee joint are usually performed using a high-frequency linear transducer (7.5–12 MHz). It is mostly used to diagnose tendon, ligament or muscle injury and cartilage and meniscal lesions.
The Proposed Products—QT Imaging Platform for extremity, infant, and whole-body imaging
The proposed QT Orthopedic Scanner for Extremity Imaging (Image 11 and Image 12) will use the open, partial angle configuration with the same platform technology as the QT Breast Scanner. Using transmission and reflection ultrasound, the system generates high definition (sub-millimeter) extremity images that provide unique visual information about the physical structures within the human musculoskeletal system. The new image information is expected to provide a safe (no radiation or injection), effective, inexpensive, and non-invasive diagnostic imaging tool for assessing musculoskeletal health. With the QT Orthopedic Scanner, the patient sits comfortably on a chair in front of the scanner that contains an opening through which the arm or leg is placed. The extremity is gently immobilized using an inflatable rubber cuff. On the other side of the rubber cuff there is a warm water bath with an ultrasound armature that rotates 325 degrees around the extremity to produce 3D images. The QT Orthopedic Scanner will differ from conventional ultrasound in that it will utilize reflection and transmission data from sound waves, providing a significant increase in diagnostic information using the speed of sound characteristics of the bones and muscles and any prosthetic devices and generating a true 3D rendering of the extremity. The QT Orthopedic Scanner will provide sub-millimeter image resolution called a QTscan which will enable identification of normal and abnormal structures and the accurate depiction of the precise shape and location of findings.
The proposed QT Orthopedic Scanner being applied to hip imaging
Image 11
The proposed QT Orthopedic Scanner being applied to shoulder imaging
Image 12
Image reconstruction of the ultrasound data is done with proprietary partial-angle segmentation software that uses the quantitative speed of sound data to highlight specific tissues for 3D visualization called a QTscan as shown in Image 13.
Volume reconstructions of the knee from QTScan data
Image 13
Clinical Images
In response to a request by the FDA to include Visual Grading Analysis studies in our applications, the Company has conducted an analysis comparing the image quality of the QTScan to MRI in which readers independently scored the image quality of 10 anatomical knee structures with MRI and the QTscan. In this Visual Grading Analysis, readers scored the transmission ultrasound images as equivalent or better than the MRI imaging in more than 90% of knees structure images reviewed. Image 14 below shows the QTScan of the knee (left) next to the MRI imaging of the knee (right). Note the higher contrast in the QTscan compared to the MRI. This exercise was conducted as part of our FDA application process and has not been published.
QTScan (left) and MRI imaging (right) of a human knee
Image 14
The following, Image 15 shows QTScan of the same knee from different views. Note the high contrast and detail in the QTScan image.
Image 15
Image 16 below shows QTScan of a human knee (left) compared with MRI views of the same knee (right). Note the higher contrast and detail in the QT image.
QTScan (left) and MRI imaging (right) of a human knee
Image 16
Image 17 below is another set of QTScan views of the same knee. Note the meniscus and cartilage detail in the QTscan images, which cannot be seen on an MRI.
QTscan of a human knee
Image 17
The Company has conducted partial-angle reconstruction studies comparing the image quality of 325-degree rotation (open angle) to 360-degree (full rotation) reconstructions (Image 18). The image quality is maintained in the partial-angle reconstruction.
360-degree rotation view (left) vs partial angle reconstruction (right) of the human knee
Image 18
Advantages of proposed QT Orthopedic Scanner
Compared to existing orthopedic imaging systems such as MRI and CT, the proposed QT Orthopedic Scanner will offer the following advantages:
The QT Orthopedic Scanner may be faster at image acquisition, resulting in quicker diagnosis and treatment.
In-office and same day orthopedic imaging
The QT Orthopedic Scanner would not require build-out of a dedicated facility with magnetic field shielding and liquid helium supply (where needed).
The QT Orthopedic Scanner may be less expensive to deploy than an MRI or CT device and may be less costly to maintain because the technology is simpler in design, has less components, does not utilize ionizing radiation, helium, and we anticipate will be less expensive to manufacture and maintain.
Proposed QT Infant Scanner—Whole Body Imaging
The Need: Currently there are very limited techniques for imaging infants. The QT Infant Scanner is in the development phase.
Medical imaging is an extremely valuable tool in diagnosing infants and children but poses specific challenges that the proposed QT Infant Scanner would address. At present neonatal and pediatric imaging is severely limited as described below.
CT uses ionizing radiation, which poses greater risk for the pediatric than adult population. The risk associated with ionizing radiation is “higher than in adults. Also, children have longer life expectancy; therefore, they have a greater potential for manifestation of possible harmful effects of radiation.”22 Ionizing radiation exposure in childhood in particular raises risk of cancer, including leukemia, breast cancer, thyroid cancer and brain cancer, where higher risk is associated with exposure any time before age two 23. This makes MRI preferred to CT for all but trauma evaluation.
MRI requires sedation or general anesthesia and may require injection of a heavy-metal contrast agent. The use of sedation or anesthetic drugs risks severe compromise of respiratory and cardiac function and injection of contrast is usually contraindicated in seriously ill children due to the high risk of organ failure from the administration of these contrast agents.
Finally, pediatric patients are particularly sensitive to environment given an infant or child’s inability to fully comprehend the nature and purpose of medical imaging. The presence of a parent or caregiver can increase imaging efficacy, but is limited in a closed environment (e.g., MRI) or an unsafe environment (e.g., any modality using ionizing radiation).
The proposed QT Infant Scanner will address all three of these issues as it will not require ionizing radiation or anesthesia and the open environment would allow a trusted adult to be present, decreasing the necessity of sedation and increasing imaging efficacy.
Although prior literature from the Company may have indicated a specific timeframe for proof of concept and rollout, there is currently no specific timeframe for the submission of premarket notification to the FDA for approval of the QT Infant Scanner. Our submission to the FDA for all products and product candidates may depend upon a number of factors and variables, including the amount of capital that we have; the completion of the clinical prototype scanner; the results from the initial pre-clinical imaging studies and comparisons with MRI; the development of an FDA-strategy-for-submission, including but not limited to pre-sub-meetings with the FDA; determining the appropriate device classification and whether it meets criteria for a 510(k) pathway, and final preparation of the FDA application.
22 See, National Library of Medicine, Problems and Preferences in Pediatric Imaging (Oct. 2015), available at https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4693383/.
23 WHO, Ionizing Radiation, Health Effects and Protective Measures (Apr. 29, 2016), available at https://www.who.int/news-room/fact-sheets/detail/ionizing-radiation-health-effects-and-protective-measures.
The Proposed Product—QT Infant Scanner
The imaging from the proposed QT Infant Scanner (the “Open Partial Angle Scanner”) Imaging (Image 19) will be based on the same platform transmission ultrasound technology as the breast and extremity scanners, and uses the Company’s Open Partial Angle Scanner concept.
The Open Partial Angle Scanner will be applied to infant body imaging in the proposed QT Infant Scanner (concept drawing)
Image 19
Clinical Images
The Company has not imaged infants but has demonstrated its ability to image the body through imaging of neonatal pigs. Comparative images for QTscan vs MRI are shown below for a neonatal pig (Image 20). Note the higher contrast and more detail in the QTscan (left).
| Whole Body QTscan | Whole Body MRI Scan |
|---|
Newborn piglet whole body imaging using the Company’s technology.
Image 20
Other anatomic detail in the newborn pig’s heart and lungs are shown in Images 21, 22, 23 and 24 using the Company’s technology.
Image 21 (left), Image 22 (center) and Image 23 (right)
Piglet Lung Imaging
Image 24
The Company has done partial-angle image reconstruction internal studies comparing the image quality of 325-degree rotation (open angle) to 360-degree (full rotation) reconstructions of a piglet’s pelvis (Image 25). We believe the image quality is maintained in the partial-angle reconstruction.
All views (left) vs partial angle reconstruction (right) of the piglet pelvis
Image 25
The Company’s Image Guided Procedures
The Need: In addition to using the Open Partial Angle Scanner as the proposed QT Infant Scanner, it can also be used for a variety of other image guided procedures including:
Breast biopsy of small lesions (<5mm)
Orthopedic biopsy of bones, joints, muscle or connective tissues
Orthopedic injections
Stem cell injections
Soft tissue ablation
Real-time non-radiation imaging of vascular procedures
Angiography without radiation
Cryoablation for early-stage breast cancer.
Cryoablation—An example of the Company’s potential contribution
Cryoablation 24 is currently approved for treatment of benign and malignant soft tissue tumors by the FDA. Currently, there are no specific technologies that have FDA approval for breast tumors, although there are over 100,000 such procedures done in the U.S. annually.25,26 Eighty-five percent of breast cancer is localized at the time of diagnosis (62% have early stage confined to the breast and 23% have pre-cancerous In Situ carcinoma).27
Cryoablation for cancer is typically used when surgery isn’t an option. Cryoablation is sometimes used as a treatment for many types of cancer, including:
Bone cancer.
Breast cancer.
Cervical cancer.
Eye cancer.
Kidney cancer.
Liver cancer.
Lung cancer.
Prostate cancer.
Mastectomy has no advantage over local removal of breast cancer in terms of survival 28 and the trend is towards less invasive or disfiguring treatments for treating the primary tumor in the breast. Cryoablation is an emerging modality of treatment with a number of different indications for use.29 Systems such as the Galil Cryoablation System 30 are used in clinical practice for a variety of applications. In one study cancer recurred in only one of 180 women treated with cryoablation for low-risk breast cancers.31 There are a number of ongoing trials in this area 32, and cryoablation is offered for low-risk breast cancers at more than 20 tertiary cancer centers in the U.S.33
24 Cryoablation is a process that uses extreme cold to destroy abnormal tissue. According to the Mayo Clinic: During cryoablation, a thin, wandlike needle called a cryoprobe is inserted through the skin. The cryoprobe is placed directly into the cancer. A gas is pumped into cryoprobe to freeze the tissue. Then the tissue is allowed to thaw. The freezing and thawing process is repeated several times
25 See, National Library of Medicine, Office-Based Cryoablation of Breast Fibroadenomas with Long-term Follow-up (Sept. 15, 2005), available at https://pubmed.ncbi.nlm.nih.gov/16174156/.
26 See, the American Society of Breast Surgeons, Consensus Guideline on the Use of Transcutaneous and Percutaneous Ablation for the Treatment of Benign and Malignant Tumors of the Breast (Oct. 16, 2018), available at https://www.breastsurgeons.org/docs/statements/Consensus-Guideline-on-the-Use-of-Transcutaneous-and-Percutaneous-Methods-for-the-Treatment-of-Benign-and-Malignant-Tumors-of-the-Breast.pdf.
27 See, ASCO, Breast Cancer: Statistics (Jan. 2022), available at https://www.cancer.net/cancer-types/breast-cancer/statistics.
28 See, JAMA Network, Use of and Mortality After Bilateral Mastectomy Compared with Other Surgical Treatments for Breast Cancer in California, 1998-2011 (Sept. 3, 2014), available at https://jamanetwork.com/journals/jama/fullarticle/1900512.
29 See, DovePress, Cryoablationin the Management of Breast Cancer: Evidence to Date (July 23, 2019), available at https://www.dovepress.com/cryoablation-in-the-management-of-breast-cancer-evidence-to-date-peer-reviewed-fulltext-article-BCTT.
30 See, Boston Scientific, Cryoablation available at https://www.bostonscientific.com/en-US/products/cryoablation.html.
31 InterventionalNews, Cryoablation Shows Promise in Treating Low-Risk Breast Cancer (Jan. 8, 2019), available at https://interventionalnews.com/cryoablation-breast-cancers/.
32 U.S. National Library of Medicine, Cryoablation Therapy in Treating Patients with Invasive Ductal Breast Cancer, available at https://clinicaltrials.gov/ct2/show/NCT00723294 (last visited Feb. 10, 2023).
33 Healio, Cryoablation May be Promising Alternative to Surgery for Low-Risk Breast Cancer (Mar. 4, 2019), available at https://www.healio.com/hematology-oncology/breast-cancer/news/online/%7Be2c51338-c13b-44f6-8690-b01307340d21%7D/cryoablation-may-be-promising-alternative-to-surgery-for-low-risk-breast-cancer.
Cryoablation of early-stage breast cancer is an exciting opportunity unique to the Company. Breast cancer cells are about 20 microns wide. A 1-cm cancer has about 100 million cells, a 0.5-cm cancer has about 10 million cells, and a 1-mm cancer has about 100 thousand cells.34 The Company’s imaging can see the glandular structure of the breast and can see as few as a couple of thousand cells. These cancers of several hundred thousand cells are very low risk to the woman and are also easily eliminated 35. There are currently limited ways to treat these small cancers using image guided procedures. The Company could offer a solution to this problem.
The Product
The product for image-guided procedures would be the Open Partial Angle Scanner augmented with enhanced software. The Open Breast Scanner is shown in Image 26 below (concept drawing).
The Open Partial Angle Scanner for Breast Imaging
Image 26
34 National Library of Medicine, Disappearing Breast Cancers (Apr. 2012), available at https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3320224/.
35 See, AJR, Robert C. Ward, Ana P. Lourenco & Martha B. Mainiero, Ultrasound-Guided Breast Cancer Cryoablation, 213 Am. J. Roentgenol. 3, 716-722 (2019), available at https://www.ajronline.org/doi/10.2214/AJR.19.21329.
The Open Partial Angle Scanner or Open Breast Scanner will be able to operate with the same accuracy as the full 360º rotation all views breast scan, as shown below (Image 27):
All views breast reconstruction (left) vs open angle breast reconstruction (right) of the same human breast
Image 27
Furthermore, the images reconstructed of scans performed on the open-angle scanner do not show any significant artifacts in the presence of an intervening device (e.g., a needle) (Image 28).
Top view (left panel) and frontal view (right panel)
An ablation needle shown in a human cadaver breast using the Company’s platform
Image 28
Manufacturing
The Company’s products are manufactured in small scale in Novato, California. With the entry into the Canon Manufacturing Agreement as discussed below, the Company will be manufacturing the QT Brast Scanners in parallel between Novato, California and using Canon Medical Systems Corporation (“CMSC”) as a contract manufacturer pursuant to the Canon Medical Agreement Starting with the second half of 2025. The products are designed under the FDA’s design control guidelines and manufactured in accordance with the Company’s quality management system.
The Company’s devices are made up of custom designed components and off-the-shelf components, both of each are supplied by the Company’s approved vendors in the U.S.
Currently all subassemblies are manufactured at the Company and verified prior to the final assembly of the device. The controls software and image reconstruction software are loaded on the imaging devices at the Company’s facility in Novato. Prior to shipping, 100% of the products are verified for functionality, performance, and safety.
The Company intends to scale up its production by initially using CMSC, and may also look at strategic original equipment manufacturing (“OEM”) agreements for large production throughput.
The suppliers that the Company purchases from and engages with are limited to those that are approved by our Quality Assurance department, which maintains an Approved Supplier List. The Company categorizes suppliers into three groups: (i) non-critical, (ii) important, and (iii) critical. For example, our “non-critical” suppliers include general distributors and/or suppliers of commercially available “off-the-shelf” items such as mechanical and electrical standard hardware, blank label stock, seals and labeling pouches, and our “important” suppliers include custom component suppliers, test facility providers and consultants.
Before a supplier is classified as “critical,” the Company assesses the supplier’s: (a) specific or proprietary core competencies, (b) tooling costs and lead time, and (c) product delivery lead time. Any supplier whose processes or products are required by the Company to be validated are classified as “critical.” Another factor that the Company considers is the lead time to approve an alternative supplier. As of the date of this annual report, although there are various suppliers in the U.S. and abroad that can produce high quality ultrasound transducers for the Company, the Company has only engaged in the supplier validation and approval process with one such supplier which manufactures ultrasound transducer subcomponents in accordance with the Company’s specifications. Because the Company has validated this supplier, but has not undertaken the significant commitment of resources to validate and approve other such suppliers of ultrasound transducers, despite the fact that the Company could choose to do so, it considers this supplier as being “critical” on our Approved Supplier List but not a principal supplier. In addition, as of the date of this annual report, the Company does not have written agreements in place with this critical supplier, and is operating under an individual purchase order platform, on an as-needed-basis; however, the Company may enter into such agreements in the future.
Canon Letter of Intent
QT Imaging entered into the Canon Letter of Intent with Canon Medical USA, Inc. (“CMSU”) and CMSC pursuant to which CMSC purchased and acquired two QT Breast Scanners in the first half of 2024. The Canon Letter of Intent provided that CMSC would conduct, and pursuant to the Feasibility Study Agreement (as described below), CMSC conducted, feasibility studies on the QT Breast Scanners that it acquired, including product quality validation, development and manufacturing studies, clinical evaluation, regulatory investigation and marketing validation (the “Feasibility Study”) The Feasibility Study was completed in the second half of 2024.
The Canon Letter of Intent provided that upon successful conclusion of the Feasibility Study, we and CMSC intended to engage in a good faith discussion to develop a binding OEM manufacturing agreement with CMSC, which we have now done, as discussed below.
CMSC will also use QT Breast Scanners that it acquired to perform clinical trials towards the possibility of it pursuing the regulatory approval process in Japan.
CMSC and QT Imaging have also discussed other potential terms between them.
Feasibility Agreement with Canon Medical Systems Corporation
On March 28, 2024, the Company entered into the Feasibility Study Agreement with CMSC. The term of the Feasibility Study Agreement commenced on March 28, 2024 and remained in force until the end of December 2024. In connection with the Feasibility Study Agreement, CMSC initiated studies to evaluate the business, technical, and clinical values of the QT Breast Scanner including the Feasibility Study. CMSC has no right to reverse engineer the QT Breast Scanner and may only modify and disassemble the QT Breast Scanner as necessary to conduct the Feasibility Study.
Under the terms of the Feasibility Study Agreement, QT Imaging provided support for the Feasibility Study as agreed with CMSC from time to time during the term of the Feasibility Study Agreement and used its commercially reasonable efforts to facilitate the Feasibility Study.
All know-how and intellectual property embodied in QT Breast Scanner are owned by QT Imaging and all rights not expressly granted to QT Imaging are reserved.
Canon Manufacturing Agreement
On March 28, 2025, the Company entered into a manufacturing agreement (the “Canon Manufacturing Agreement”) with CMSC. Pursuant to the terms of the Canon Manufacturing Agreement, the Company appoints CMSC as the exclusive manufacture of the QT Breast Scanners to be distributed by NXC Imaging, a wholly-owned subsidiary of CMSU (“NXC”) pursuant to the Amended Distribution Agreement (as defined below). CMSC’s manufacturing of the QT Breast Scanners shall not include the final testing process for the QT Breast Scanners, and CMSC shall not have any responsibility for the QT Breast Scanner as a manufacturer of medical equipment for FDA purposes.
In order for CMSC to manufacture the QT Breast Scanners, the Company shall sell components to CMSC in a timely manner, in accordance with agreed-upon terms and conditions. The Company shall cooperate with and support CMSC to allow CMSC to procure components through its own supply chain. The parties shall negotiate in good faith specific procedures to phase out CMSC’s purchase of components from the Company, with the target date of the fourth quarter of 2025, although this is not a commitment. The terms for purchasing components (or subassemblies), including components for service, by the Company from CMSC shall be mutually agreed upon by the parties.
The Company shall provide forecasts (each, a “Forecast”) to CMSC in accordance with the “Forecast Policy” attached to the Canon Manufacturing Agreement. No later than forty-five days prior to the end of each calendar quarter, CMSC will notify the Company in writing if CMSC is unable to deliver a sufficient number of QT Breast Scanners to satisfy the Forecast for the following quarter. If CMSC is unable to deliver a sufficient number of QT Breast Scanners due to CMSC’s willful misconduct, CMSC will sell back to the Company all components necessary for the Company to engage in the manufacture of the QT Breast Scanners for the following quarter at the Company’s facility in Novato, California (hereinafter referred to as “Novato Manufacturing”) sufficient to cover the QT Breast Scanner shortfall back at the same purchase price that CMSC paid to purchase such components. CMSC shall bear risk of loss, all fees and shipping costs for the components incurred in connection with such Novato Manufacturing.
No later than forty days prior to the end of each calendar quarter, the Company shall notify CMSC in writing indicating whether or not the Company wishes to engage in Novato Manufacturing of the QT Breast Scanners for the following quarter for the purpose of meeting the Forecast for such quarter. If the Company provides such notice to CMSC within the 40-day period, stating that the Company wishes to engage in Novato Manufacturing, the Company may purchase from CMSC (if the Company does not already have) any components held by CMSC necessary as determined by the Company for the Company to be able to manufacture the QT Breast Scanners via the Novato Manufacturing, at the same purchase price that CMSC paid to the Company to purchase such components. The Company shall bear all risk of loss, fees and shipping costs for the components incurred in connection with the Novato Manufacturing.
From time to time during the term of the Canon Manufacturing Agreement, but no later than thirty days prior to the delivery date specified in the purchase order, the Company may issue to CMSC a purchase order for any of the QT Breast Scanners necessary to meet the Forecast, for the actual quantities to be delivered by CMSC. Each purchase order shall specify delivery dates that respect the “Forecast Policy.” The purchase prices applicable to the purchase orders as of the date of the Canon Manufacturing Agreement shall be separately agreed between the parties in writing. CMSC may reject any purchase order that requests delivery dates that are not in compliance with such Forecast Policy. Unless the Company is manufacturing QT Breast Scanners as Novato Manufacturing, any failure by CMSC, as a result of CMSC’s conduct, to manufacture and deliver QT Breast Scanners as specified in an accepted purchase order necessary to satisfy the Forecasts later than seventy-five days from the delivery date as specified in the accepted purchase order shall result in liquidated damages per missed or delayed QT Breast Scanner of $220,000, with NXC not being obligated to pay for the missed MOQ sale. Such failure by CMSC shall also not provide any grounds for NXC to terminate the Amended Distribution Agreement or otherwise cancel the binding nature of the MOQs (as defined below) as provided in the Amended Distribution Agreement (as described below). All title to and risk of loss of the QT Breast Scanners shall pass from CMSC to the Company when the QT Breast Scanners have been delivered to the Company in Novato, California, under the Incoterms 2020 trade term, DDP. The Company shall make payment of the QT Breast Scanners to CMSC within ninety days after the issuing date of an original copy of the invoice to be issued by CMSC.
Prior to the delivery of the QT Breast Scanners, CMSC shall inspect and test all the QT Breast Scanners in accordance with the outgoing test procedures to be approved in writing by the Company and as specified in the specifications or otherwise to be separately agreed upon between the parties in writing. The Company shall perform the visual, quantity and/or quality inspection of the QT Breast Scanners upon their receipt. If any of the QT Breast Scanners delivered is found deficient in quantity (as set forth in the accepted purchase order), or is defective in material and workmanship or inconformity with the specifications, and such deficiency, defect or non-conformity is caused by CMSC, the Company may submit a written claim notice to CMSC with sufficient supporting evidence, including but not limited to photographs and reasonably detailed explanation. CMSC shall, at its sole discretion, either (i) deliver additional QT Breast Scanners to fulfil the required quantity or deliver replacement of the QT Breast Scanners, or (ii) offer an equitable reduction in the purchase price of the QT Breast Scanners delivered, subject to mutual agreement between the parties. CMSC is providing a warranty on the QT Breast Scanners that they shall be free from defects in material and workmanship and conform to the specifications for a period of (i) twelve months from the delivery date of each QT Breast Scanner from the Company to NXC, or (ii) twelve months from the installation date for the QT Breast Scanners directly sold to end users by the Company. If any defects in material and workmanship, or non-conformity of the specifications occur during the warranty period and the Company provides a timely claim, CMSC shall, at its sole discretion (i) send a replacement of a part(s), (ii) send a brand new QT Breast Scanner as a replacement, (iii) repair the defective QT Breast Scanner(s) and return them to the Company, or (iv) refund the equivalent price to the purchase price. CMSC shall only be responsible for recalls resulting from the manufacturing process of the QT Breast Scanners or materials and parts procured by CMSC (other than materials and parts procured from the Company).
All intellectual property rights, including but not limited to patents, copyrights, know‑how, and trade secrets (the “IPR”), which each party has owned before entry into the Canon Manufacturing Agreement or develops separately from the performance of the manufacture of the QT Breast Scanners under this agreement, shall remain the exclusive property of the Company or CMSC respectively. All IPR in and to any invention, whether patentable or not, conceived and reduced to practice in the performance of the manufacture of the QT Breast Scanners under the Canon Manufacturing Agreement shall be owned solely by CMSC; provided, that to the extent that such invention is based on the Company’s confidential information and is exercised on the QT Breast Scanners which are manufactured by CMSC and delivered to the Company, such as manufacturing process flow, CMSC agrees not to assert any IPR in and to such invention against the Company, its affiliates and customers as to the QT Breast Scanners. All IPR to and in any invention, whether patentable or not, if agreed between the parties to have been conceived and reduced to practice jointly by the Company and CMSC in the performance of the manufacture of the QT Breast Scanners shall be owned jointly and equally by the Company and CMSC, and both parties shall have the right to use, utilize and exploit such IPR in accordance with applicable laws involved without a prior consent of or any payment or consideration to the other party.
The Company hereby grants to CMSC a personal and exclusive license to use, utilize (including copy, amend, revise and modify) and exercise the IPR owned by the Company solely for enabling it to manufacture the QT Breast Scanners sold to NXC and provide maintenance support for them, provided that (i) such exclusive license may be sublicensed to NXC and other subsidiaries of CMSC and/or authorized maintenance companies (with such authorization to be provided in writing by the Company, but not to be unreasonably refused, withheld, or delayed) that provide maintenance services on an outsourced basis (the “Approved Parties”) solely for the QT Breast Scanners distributed by NXC pursuant to the Amended Distribution Agreement, whether or not the QT Breast Scanners are distributed before, on, or after the entry into the Canon Manufacturing Agreement; otherwise such license shall be non-exclusive, non‑sublicensable and non-transferable, and (ii) CMSC shall refrain from using its license to amend, revise and modify the QT Breast Scanners, including the source code(s) of software (which shall be held in escrow pursuant to the terms of a separate escrow agreement among the parties and an escrow agent (the “Escrow Agreement”)), unless the Company becomes party to an event of any bankruptcy or other insolvency proceeding (a “QTI Bankruptcy”).
If there is a QTI Bankruptcy, CMSC may use its license in accordance with the following: in the event of a QTI Bankruptcy and rejection or termination of the Canon Manufacturing Agreement in a QTI Bankruptcy, all source code(s) will be released by the escrow agent to CMSC and CMSC may exercise its rights to amend, revise and modify such source code(s) (A) to enable CMSC to manufacture (x) up to 100 QT Breast Scanners to be sold to NXC or (y) in the event that 100 QT Breast Scanners have yet to be sold to NXC by December 31, 2026, QT Breast Scanners until December 31, 2026, whichever occurs earlier, and (B) to enable CMSC and the Approved Parties until the earlier of (i) the end of the five-year lifetime of the QT Breast Scanners sold to NXC pursuant to the Amended Distribution Agreement and (ii) December 31, 2031 (such earlier date, the “Maintenance Term”) to support the continuous workable operation, but not for upgrades or improvement of performance, of QT Breast Scanners that were distributed by NXC before, on, or after the Canon Manufacturing Agreement. Following the expiration of the Maintenance Term, CMSC shall return to the Company or its successor physical material released to CMSC by the escrow agent and use commercially reasonable efforts to erase electronically submitted material released to it by the escrow agent, provided, however, that CMSC shall be permitted to retain information stored on backup or archival media pursuant to bona fide security measures or for legal compliance. In the event that prior to a QTI Bankruptcy, CMSC terminates the Canon Manufacturing Agreement, other than because the Company has substantially failed to comply with any provision of the Canon Manufacturing Agreement and that such non-compliance has not been cured within thirty business days from the date of the Company’s receipt of the written notice from CMSC, in the event of a QTI Bankruptcy there shall be no release of source code(s). Furthermore, in the event that prior to a QTI Bankruptcy, CMSC terminates this agreement because the Company has substantially failed to comply with any provision of the Canon Manufacturing Agreement and that such non-compliance has not been cured within thirty business days from the date of the Company’s receipt of the written notice from CMSC and there is a subsequent QTI
Bankruptcy, the usage by CMSC of the source code released to CMSC pursuant to this Article 9.3.2 shall be limited to subpart (B) set forth in the first sentence of this paragraph. Furthermore, if the Company terminates the Canon Manufacturing Agreement in the event that CMSC substantially fails to comply with any provision of the Canon Manufacturing Agreement and that such non‑compliance has not been cured within thirty business days from the date of its receipt of the written notice from the Company, then there shall be no release of source code(s) to CMSC.
Unless earlier terminated in accordance with the terms of the Canon Manufacturing Agreement, this agreement shall remain effective until December 31, 2026. In case both parties mutually agree the extension of the Canon Manufacturing Agreement in writing, the Canon Manufacturing Agreement shall be extended for one year after the expiration of the Canon Manufacturing Agreement. In the event of “Change of Control” of a party, either party shall have the right to, at its sole discretion, terminate the Canon Manufacturing Agreement in its entirety upon forty-five business days’ prior written notice to the other party. Such notice shall be provided prior to the expiration of the then current term of the Canon Manufacturing Agreement. In the event of the termination or expiration of the Canon Manufacturing Agreement, CMSC will honor all of the outstanding accepted purchase orders, and both parties will cooperate to fulfill such orders. In the event that either party substantially fails to comply with any provision of the Canon Manufacturing Agreement and that such non-compliance has not been cured within thirty business days from the date of its receipt of the written notice from the other party, then the other party shall have the right to terminate the Canon Manufacturing Agreement upon giving a written notice. The Canon Manufacturing Agreement also provides other grounds for its termination prior to December 31, 2026, including by CMSC if NXC’s sales of the QT Breast Scanner are adversely affected due to any failures or other circumstances attributable to the Company that the Company is or is reasonably expected to be unable to remedy (including but not limited to Epidemic Failures; the submission of Medical Device Reports (MDRs) to the FDA regarding the QT Breast Scanner; any action by the Company (either voluntarily or upon an order or request by the FDA) to conduct a Field Correction, Market Withdrawal, Stock Recovery, or Recall (as such terms are defined by the FDA); any action by the Company or any regulatory authority to temporarily suspend shipments or manufacturing of QT Breast Scanners; or issues related to the Company’s business operations) within six months from the date of the onset of such an event. For these purposes, “Epidemic Failures” means a malfunctioning of five or more QT Breast Scanners collectively presumed to have a common underlying cause based on a reasonable evaluation. Following a termination or expiration of the Canon Manufacturing Agreement, the provisions with respect to the grants of licenses to the IPR of the Company will survive up to the earlier of (a) the end of the five-year lifetime of the QT Breast Scanners sold to NXC and (b) December 31, 2031.
The foregoing description is qualified in its entirety by reference to the Canon Manufacturing Agreement, a copy of which is attached hereto as Exhibit 10.46 and incorporated herein by reference.
Sales and Marketing
The Company’s primary sales and marketing efforts in the short-to-medium term will be to focus on the $3 billion breast imaging market in United States supported by the exclusive partnership with our distribution partner, NXC Imaging.
Leverage Current Clearances to Build Presence and Awareness in the Medical Community
The current QT Breast Scanner is a Class II device subject to premarket notification and clearance under Section 510(k) of the FDCA. The QT Breast Scanner is currently cleared by the FDA under Section 510(k) (which clearance was granted in June 2017) for breast imaging but not as a replacement for screening mammography – currently, the device has FDA approval and can be reimbursed in cases where additional breast imaging is necessary. This includes women who need adjunctive screening, such as: women with dense breasts or where there is a finding; high risk women below the recommended age for mammography; and women who would benefit from more frequent breast imaging, such as women undergoing treatment or women on prophylactic medication to prevent breast cancer.
Many patients may find QT Imaging modality preferable for dense breasts, implants, post therapy screening where breasts can be very sensitive to compression and where patients have concerns about the radiation dose.
A particular opportunity for the Company under its current clearance is to provide a backup option for women who are recommended for a breast MRI but are unwilling or unable to have it for cost or accessibility reasons. With additional clinical data comparing the clinical efficacy of the QT Breast Scanner to MRIs, the QT Breast Scanner may become a less expensive, more patient-friendly alternative to MRIs (no contrast-dye, no claustrophobia, no noise). QT Scanners will free MRI scanners for other non-breast imaging studies.
Achieving clinical adoption requires building awareness and acceptance in the medical community. The first step will be to place machines with early adopters who see the benefits of the Company’s technology, are interested in using the device in their practice, are willing to collect data on its use, and will publish results or speak to their peers about its clinical value.
An example of this strategy in practice is the National Cancer Institute grant received in 2022 in partnership with the University of Illinois – Urbana-Champaign whereby the Company will place a QT Breast Scanner at St. Margaret’s Hospital in Toronto, Canada. The objective is to evaluate and measure the effectiveness of the QTscan in evaluation and monitoring cancer treatment in comparison to breast MRI which is currently the standard-of-care in quantitative monitoring of response to therapy. The results of the study will be published and would represent an independent validation of the clinical value of the QTscan with the imprimatur of a respected university, hospital, and the National Cancer Institute. The Company intends to establish similar peer-review partnerships with respected medical organizations, practices, and practitioners in the future.
Sales and Marketing Strategy
The Company’s sales efforts are supported by partnership with strategic sales and distributors partners, with solid channels in the industry and large sales organizations. The Company will scale scanner placements in hospitals, imaging centers, and health centers via such partnerships.
Use an Installed Base as a Platform to Expand Awareness and Produce Additional Data for Clinical Acceptance, Reimbursement, and Additional FDA Clearances
Part of the challenge of achieving clinical acceptance and adoption of the Company’s technology is data that proves the efficacy of the QTscan relative to the current standard of care for breast imaging in screening, diagnosis and treatment. The rollout of QT Breast Scanners as described in the previous section will provide multiple means of collecting this data for clinicians, which can also be used to support reimbursement and expanded FDA clearances of the QT Breast Scanner as an alternative to screening breast MRI in younger women (under 40 years of age) with above average risk of breast cancer.
Data collection and analysis, support reimbursement and expanding FDA clearances are time-consuming, but with the help of the installations that will be accelerated through the placement programs detailed above, the Company believes that it can achieve these objectives with maximum efficiency.
Market Segments
As the installed base for QT Breast Scanners expands, and as discussed above, the Company intends to tailor its marketing efforts towards three segments as it builds awareness and acceptance for its imaging technology. All are important for success, and each requires its own strategy and messaging.
Patients. This is the end-user/consumer – the women who are dissatisfied with the current scanning model. The Company intends to approach patients through multiple channels, beginning with outreach efforts to recruit key influencers and opinion leaders. These individuals would be recruited through networking and education via targeted interest groups and would become advocates of the benefits of the Company’s technology to their respective groups.
Medical Professionals/Radiologists. In addition to marketing to women, the Company launched an intensive campaign aimed at the medical community. This is a more difficult effort than that aimed at women – from the provider perspective, the need for multiple scans and callbacks that are a negative for patients are actually seen as an economic positive as additional patient visits generate a significant amount of revenue. This is true for both institutions and radiologists, and neither have a great incentive to deviate from the current status quo.
NXC Distribution Agreement
We are supported by a strong distribution and business partnership with NXC. On May 13, 2023, QT Imaging entered into the NXC Sales Agent Agreement with NXC, pursuant to which QT Imaging appointed NXC as the non-exclusive agent for the sale of the QT Breast Scanner and related services in non-exclusive territories: the U.S., U.S. territories, and U.S. Department of Defense installations. Additionally, NXC was appointed as the exclusive servicer of the QT Breast Scanners sold by NXC under the terms of the NXC Sales Agent Agreement. Under the NXC Sales Agent Agreement, QT Imaging had the right to set the price for its products and agreed to pay NXC a commission based on the purchase order price charged to a customer. Pursuant to the NXC Sales Agent Agreement, NXC was responsible for promotion and sale of the QT Breast Scanner and related services within the designated territory, as well as servicing the QT Breast Scanners sold by NXC. The initial term of the NXC Sales Agent Agreement was for three years.
Subsequently, effective June 10, 2024, we and NXC replaced the NXC Sales Agent Agreement with the NXC Distribution Agreement. Under the NXC Distribution Agreement, NXC is appointed as the exclusive reseller to market, advertise, and resell QT Breast Scanners in the U.S. and U.S. territories. NXC will purchase for the purpose of reselling, leasing or renting QT Breast Scanners directly to its customers, but is not obligated to purchase any particular quantity of QT Breast Scanners from us. We have reserved the right to sell directly to customers as an exception. Furthermore, we may, in our sole discretion, sell the QT Breast Scanners to any other person or entity anywhere in the world without notice to NXC or NXC’s prior consent. NXC is also allowed to assign sales agents for the purpose of QT Breast Scanner sales. NXC’s purchases will be in accordance with an agreed upon product pricing schedule (subject to change upon 60 days’ prior written notice by us), provided that neither NXC nor its assigned sales agents may mark-up the cost of the QT Breast Scanners more than twenty percent (20%) unless otherwise mutually agreed to between NXC and us. Each order will include information reasonably requested by us and is subject to our acceptance, after which it becomes an approved order. Any such approved orders are non-cancellable and not subject to rescheduling after acceptance by us. Any orders not accepted by us in writing are deemed rejected.
On October 29, 2024, we and NXC entered into Amendment No. 1 to the Distribution Agreement (the “First Amendment”) to expand Section 20 of the NXC Distribution Agreement to provide that NXC shall be obligated to inform its customers who purchase the QT Breast Scanner (the “Equipment”) that such customers shall not (i) use, copy, distribute, display, perform, or prepare derivative works of any materials accompanying or embodied in the Equipment (except to the extent expressly permitted by such customer’s license to such Equipment and its documentation) or (ii) use any Seller Marks (as defined in the NXC Distribution Agreement), in each case without our prior written consent. Further, the First Amendment provides that upon any unauthorized use of the Seller Marks or materials accompanying the Equipment by any customer, NXC shall promptly inform us and provide all reasonably requested assistance in termination such unauthorized use.
On December 11, 2024, we and NXC entered into the Amended Distribution Agreement, which amends and restates the NXC Distribution Agreement in its entirety. The Amended Distribution Agreement provides for the following modifications to the NXC Distribution Agreement, with the balance of terms (including those added by the First Amendment) remaining materially unchanged:
Sale of Equipment
Under terms of the Amended Distribution Agreement, in the event that CMSC enters into an OEM manufacturing agreement, then fulfillment by the parties to such manufacturing agreement of their respective obligations under such manufacturing agreement shall be a condition to NXC being the exclusive reseller to market, advertise, and resell the Equipment in the U.S. and U.S. territories.
Minimum Order Quantities and Pricing
The Amended Distribution Agreement provides that no later than five days prior to the end of each calendar quarter, NXC shall provide to us a forecast of the anticipated purchases of Equipment during the subsequent twelve-month period. The Amended Distribution Agreement further provides that the forecast for 2025 and 2026 shall be no less than the Minimum Order Quantities (the “MOQs”) set forth in an exhibit to the Amended Distribution Agreement, by quarter and by year. Furthermore, all purchase orders from NXC shall be for no less than the MOQs, which NXC must order on the quarterly and annual basis as set forth in an exhibit to the Amended Distribution Agreement. However, in the event that the we and CMSC do not enter into an OEM manufacturing agreement, then the MOQs shall be non-binding only in the event that we cannot fulfill the manufacture and delivery volumes required for NXC to meet the MOQs.
Should NXC fail to submit a purchase order for no less than the MOQs in any quarterly or annual period, then we may invoice NXC and NXC shall pay us for the difference between the Equipment purchased and the MOQs for such period.
NXC’s purchases will be in accordance with a product pricing schedule attached to the Distribution Agreement as an exhibit (subject to change upon 60 days’ prior written notice by us). The Amended Distribution Agreement removed the cap on markup by NXC on its resale of the cost of the Equipment that was provided for by the NXC Distribution Agreement, such that NXC may set the resale price for customers at its sole discretion.
Payment Terms
Except as otherwise set forth in an applicable Approved Order, the Amended Distribution Agreement provides that we will invoice NXC upon shipment of the Equipment and NXC shall pay the invoice by net thirty days from shipment of the Equipment.
After Sale Service
The Amended Distribution Agreement obligates us to continue to provide technical support, spare parts, and necessary know-how in order for NXC to continue to service and support Equipment for at least five years after installation of the Equipment at a customer site. The Amended Distribution Agreement also deleted a provision in the NXC Distribution Agreement that required NXC to request each of its customers to have a qualified or trained breast radiologist.
Limited Warranty
The Amended Distribution Agreement contains limited warranties with respect to the Equipment and relevant spare parts, to remain in effect (a) for Equipment for the shorter of fifteen months from the shipment of the Equipment or twelve months from the date of customer acceptance of installed Equipment, and (b) the relevant spare parts for the shorter of twelve months from the date of their shipment and six months from the date that their completion is installed.
Non-Solicitation
The Amended Distribution Agreement contains a non-solicitation provision stating that we agree, during the term thereof and for a period of three years after, we shall not, directly or indirectly: (a) interfere with or attempt to interfere with any relationship between NXC and any of its distributors, agents, employees, consultants, independent contractors, agents or representatives, (b) solicit the business or accounts of NXC, or (c) divert or attempt to direct from NXC any business or interfere with any relationship between the NXC or any of its clients, suppliers, customers or other business relations; provided, however, that we may engage with the end customers that have acquired the Equipment to the extent necessary to enable such end customers to utilize the Equipment. Furthermore, to the extent not otherwise prohibited by law, each party agrees that, during the term of the Amended Distribution Agreement and for a period of three years after, each party shall not, directly or indirectly solicit for employment the employees of the other except to the extent that such solicitation is done through a general advertisement or solicitation that is not specifically targeting the employees of the other.
Term
The Amended Distribution Agreement extends the term from December 31, 2025 until December 31, 2026, unless earlier terminated or extended by mutual written agreement.
On March 28, 2025, we entered into Amendment No. 1 to the Amended and Restated Distribution Agreement (the “First Amendment to A&R Distribution Agreement”). The First Amendment to A&R Distribution Agreement amends certain provisions of the Amended Distribution Agreement. It provides, among other things, that we reserve the right to sell the Equipment directly to a third party as an exception, and any such direct sale by us shall occur after a prior written notification to NXC and shall count towards the MOQs, provided that if a third party is a competitor of NXC as defined in the First Amendment to A&R Distribution Agreement or an existing customer of NXC or NXC’s reseller or sales agent at the time when we seek to sell the Equipment directly to the third party, we may not sell the Equipment to such third party. It also provides that NXC shall provide us with the forecast of the anticipated purchases of Equipment during the subsequent twelve-month period no later than forty-five days prior to the end of each calendar quarter, rather than five days prior to the end of each calendar quarter. No changes are made to the amount of the MOQs by the First Amendment to A&R Distribution Agreement, but the MOQs shall not be binding if at any time (a) we cannot fulfill the manufacturing and delivery volumes required for NXC to meet the quarterly MOQs, including due to (i) failures or other circumstances attributable to us including, but not limited to, issues relating to design or performance of the Equipment (e.g., failure of the Equipment to meet its published specifications), orders by the FDA or another governmental organization to temporarily or permanently suspend shipments, and to activities or operations of QTI, or (ii) a final non-appealable judgment that would impair our ability to fulfill such manufacturing and distribution volumes as a result of (A) intellectual property infringement made by a third party relating to the Equipment or (B) other legal proceedings against us; or (b) we engage with any competitor or existing customers of NXC or its reseller or sales agent to sell the Equipment in violation of the terms of the Amended Distribution Agreement, as amended. Furthermore, the First Amendment to A&R Distribution Agreement provides that in the event NXC is prevented from selling the Equipment due to actions of or attributable to us, we and NXC will discuss in good faith. We also agreed to introduce at least one new product improvement per year to the Equipment, that we will also timely correct all Equipment bugs or other defects as necessary to address performance issues, and that any increases of the price of the Equipment shall be upon mutual agreement of the parties. Also, in the event of an Equipment Recall (as such term is defined in the First Amendment to A&R Distribution Agreement), the First Amendment to A&R Distribution Agreement provides both parties shall promptly consult and cooperate with the other party, including with respect to the appropriate action to be taken in connection with such Equipment Recall, and mutually agree to appropriately modify the MOQs for the respective quarter or until the Equipment Recall is corrected with mutual agreement with NXC.
The foregoing description is qualified in its entirety by reference to the First Amendment to A&R Distribution Agreement, a copy of which is attached hereto as Exhibit 10.47 and incorporated herein by reference.
Selectively Consider Offshore Marketing Opportunities
Although we have primarily focused our resources on the U.S. market, QT Imaging did commence some marketing initiatives outside the U.S. Pursuant to the Innovador Distribution Agreement between QT Imaging and Innovador, dated November 2, 2022, QT Imaging appointed Innovador as QT Imaging’s distributor for much of Asia. The Asia market is attractive as the incidence of dense breast tissue in Asian women 36 is higher than that in the U.S. women 37.The territory for the Innovador Distribution Agreement includes Singapore, Malaysia, Thailand, Indonesia, Philippines, Myanmar, Vietnam, Cambodia, Laos, Brunei, India, Pakistan, Sri Lanka, Bangladesh, Nepal, Mongolia, Taiwan, Hong Kong, and Macau. Under the Innovador Distribution Agreement, QT Imaging is responsible for developing and manufacturing its products and supporting Innovador’s product registration and sales and marketing efforts, and Innovador is responsible for product registration, market development, sales & marketing, distribution, and service of the QT Imaging products. Under the Innovador Distribution Agreement, Innovador provides QT Imaging with nonbinding forecasts of the volume of QT Imaging’s products it expects to sell each year. Innovador takes possession of any machines it purchases.
The initial term of the Innovador Distribution Agreement is three years. Either party may terminate the Innovador Distribution Agreement if the counterparty breaches the agreement, engages in fraudulent conduct, becomes insolvent or is adjudicated bankrupt, or fails to function as a viable and operative concern or to conduct its operations in the normal course of business.
Government Regulation
Our existing product, the QT Breast Scanner, products under development, and our operations are subject to extensive regulation by the FDA, and other federal and state authorities in the U.S., as well as comparable authorities in foreign jurisdictions. Our products do not emit radiation, but are subject to regulation as medical devices in the U.S. under the FDCA and as implemented and enforced by the FDA, and under comparable regulatory schemes in foreign jurisdictions.
FDA Regulation of Medical Devices
The FDA regulates the development, design, non-clinical and clinical research, manufacturing, safety, efficacy, labeling, packaging, storage, installation, servicing, recordkeeping, premarket clearance or approval, adverse event reporting, advertising, promotion, marketing and distribution, and import and export of medical devices to ensure that medical devices distributed within the U.S. are safe and effective for their intended uses and otherwise meet the requirements of the FDCA.
FDA Premarket Clearance and Approval Requirements
Subject to certain exceptions, each medical device commercially distributed in the U.S. requires either FDA clearance of a 510(k) premarket notification, or approval of a pre-market approval application (“PMA”). Under the FDCA, medical devices are classified into one of three classes-Class I, Class II or Class III-depending on the degree of risk associated with each medical device and the extent of manufacturer and regulatory control needed to ensure its safety and effectiveness. Class I includes devices with the lowest risk to the patient and are those for which safety and effectiveness can be assured by adherence to the FDA’s General Controls for medical devices, which include compliance with the applicable portions of Quality System Regulation (“QSR”), facility registration and product listing, reporting of adverse medical events and truthful and non-misleading labeling, advertising and promotional materials. Class II devices are subject to the FDA’s General Controls, and special controls as deemed necessary by the FDA to ensure the safety and effectiveness of the device. These special controls can include performance standards, post-market surveillance, patient registries and FDA guidance documents.
While most Class I devices are exempt from the 510(k) premarket notification requirement, manufacturers of most Class II devices are required to submit to the FDA a premarket notification under Section 510(k) of the FDCA requesting permission to commercially distribute the device. The FDA’s permission to commercially distribute a device subject to a
36 See, American Journal of Roentgenology, Mammographic Breast Density and Race (Apr. 2007), Table 1, available at https://www.ajronline.org/doi/10.2214/AJR.06.0619#:~:text=This%20study%20shows%20that%20Asians.
37 See, CDC, What does it Mean to Have Dense Breasts, available at https://www.cdc.gov/breast-cancer/about/dense-breasts.html?CDC_AAref_Val=https://www.cdc.gov/cancer/breast/basic_info/dense-breasts.htm (last visited Jan. 4, 2024).
510(k) premarket notification is generally known as 510(k) clearance. Devices deemed by the FDA to pose the greatest risks, such as life sustaining, life supporting or some implantable devices, or devices that have a new intended use, or use advanced technology that is not substantially equivalent to that of a legally marketed device, are placed in Class III, requiring approval of a PMA. Some pre-amendment devices are unclassified, but are subject to the FDA’s premarket notification and clearance process in order to be commercially distributed.
510(k) Clearance Marketing Pathway
The current QT Breast Scanner is a Class II device, and we expect products under development such as the QT Infant Scanner and the QT Orthopedic Scanner will also be Class II devices subject to premarket notification and clearance under section 510(k) of the FDCA. To obtain 510(k) clearance, we must submit to the FDA a premarket notification submission demonstrating that the proposed device is “substantially equivalent” to a predicate device already on the market. A predicate device is a legally marketed device that is not subject to premarket approval, i.e., a device that was legally marketed prior to May 28, 1976 (pre-amendments device), and for which a PMA is not required, a device that has been reclassified from Class III to Class II or I, or a device that was found substantially equivalent through the 510(k) process. The FDA’s 510(k) clearance process usually takes from three to twelve months, but often takes longer. The FDA may require additional information, including clinical data, to make a determination regarding substantial equivalence. In addition, the FDA collects user fees for certain medical device submissions and annual fees and for medical device establishments. For fiscal year 2025, the small business user fee for a 510(k) premarket notification application is $9,280. If the FDA agrees that the device is substantially equivalent to a predicate device currently on the market, it will grant 510(k) clearance to commercially market the device. If the FDA determines that the device is “not substantially equivalent” to a previously cleared device, the device is automatically designated as a Class III device. The device sponsor must then fulfill more rigorous PMA requirements, or can request a risk-based classification determination for the device in accordance with the “de novo” process, which is a route to market for novel medical devices that are low to moderate risk and are not substantially equivalent to a predicate device.
After a device receives 510(k) marketing clearance, any modification that could significantly affect its safety or effectiveness, or that would constitute a major change or modification in its intended use, will require a new 510(k) clearance or, depending on the modification, PMA approval or de novo reclassification. The FDA requires each manufacturer to determine whether the proposed change requires submission of a 510(k), a de novo request or a PMA in the first instance, but the FDA can review any such decision and disagree with a manufacturer’s determination. If the FDA disagrees with a manufacturer’s determination, the FDA can require the manufacturer to cease marketing and/or request the recall of the modified device until 510(k) marketing clearance or until PMA approval is obtained or a de novo request is granted. Also, in these circumstances, the manufacturer may be subject to significant regulatory fines or penalties.
Over the last several years, the FDA has proposed reforms to its 510(k) clearance process, and such proposals could include increased requirements for clinical data and a longer review period, or could make it more difficult for manufacturers to utilize the 510(k) clearance process for their products. For example, in November 2018, the FDA officials announced forthcoming steps that the FDA intends to take to modernize the premarket notification pathway under Section 510(k) of the FDCA. Among other things, the FDA announced that it planned to develop proposals to drive manufacturers utilizing the 510(k) pathway toward the use of newer predicates. These proposals included plans to potentially sunset certain older devices that were used as predicates under the 510(k) clearance pathway, and to potentially publish a list of devices that have been cleared on the basis of demonstrated substantial equivalence to predicate devices that are more than 10 years old. In May 2019, the FDA solicited public feedback on these proposals. The FDA requested public feedback on whether it should consider certain actions that might require new authority, such as whether to sunset certain older devices that were used as predicates under the 510(k) clearance pathway. These proposals have not yet been finalized or adopted, and the FDA may work with Congress to implement such proposals through legislation.
More recently, in September 2019, the FDA finalized guidance describing an optional “safety and performance based” premarket review pathway for manufacturers of “certain, well-understood device types” to demonstrate substantial equivalence under the 510(k) clearance pathway by showing that such device meets objective safety and performance criteria established by the FDA, thereby obviating the need for manufacturers to compare the safety and performance of their medical devices to specific predicate devices in the clearance process. The FDA intends to develop and maintain a list of device types appropriate for the “safety and performance based” pathway and will continue to develop product-specific guidance documents that identify the performance criteria for each such device type, as well as the testing methods recommended in the guidance documents, where feasible.
PMA Approval Pathway
If any of our products are classified as Class III, they will be subject to a PMA approval process. At this time, we believe, but cannot be certain, that our devices will be approved under Class II, thus avoiding the time consuming and expensive PMA approval pathway. Class III devices require PMA approval before they can be marketed, although some pre-amendment Class III devices for which the FDA has not yet required a PMA are cleared through the 510(k) process. The PMA process is more demanding than the 510(k) premarket notification process. In a PMA, the manufacturer must demonstrate that the device is safe and effective, and the PMA must be supported by extensive data, including data from preclinical studies and human clinical trials. The PMA must also contain a full description of the device and its components, a full description of the methods, facilities and controls used for manufacturing and proposed labeling. Following receipt of a PMA, the FDA determines whether the application is sufficiently complete to permit a substantive review. If the FDA accepts the application for review, it has 180 days under the FDCA to complete its review of a PMA, although in practice, the FDA’s review often takes significantly longer, and can take up to several years. An advisory panel of experts from outside the FDA may be convened to review and evaluate the application and provide recommendations to the FDA as to the approvability of the device. The FDA may or may not accept the panel’s recommendation. In addition, the FDA will generally conduct a pre-approval inspection of the applicant or its third-party manufacturers’ or suppliers’ manufacturing facility or facilities to ensure compliance with the QSR.
The FDA will approve the new device for commercial distribution if it determines that the data and information in the PMA constitute valid scientific evidence and that there is reasonable assurance that the device is safe and effective for its intended use(s). The FDA may approve a PMA with post-approval conditions intended to ensure the safety and effectiveness of the device, including, among other things, restrictions on labeling, promotion, sale and distribution and collection of long-term follow-up data from patients in the clinical study that supported PMA approval or requirements to conduct additional clinical studies post-approval. The FDA may condition PMA approval on some form of post-market surveillance when deemed necessary to protect the public health or to provide additional safety and efficacy data for the device in a larger population or for a longer period of use. In such cases, the manufacturer might be required to follow certain patient groups for a number of years and to make periodic reports to the FDA on the clinical status of those patients. Failure to comply with the conditions of approval can result in material adverse enforcement action, including withdrawal of the approval.
Certain changes to an approved device, such as changes in manufacturing facilities, methods or quality control procedures, or changes in the design performance specifications, which affect the safety or effectiveness of the device, require submission of a PMA supplement. PMA supplements often require submission of the same type of information as a PMA, except that the supplement is limited to information needed to support any changes from the device covered by the original PMA and may not require as extensive clinical data or the convening of an advisory panel. Certain other changes to an approved device require the submission of a new PMA, such as when the design change causes a different intended use, mode of operation, and technical basis of operation, or when the design change is so significant that a new generation of the device will be developed, and the data that were submitted with the original PMA are not applicable for the change in demonstrating a reasonable assurance of safety and effectiveness. We do not currently expect any of our products to be marketed pursuant to a PMA.
Clinical Trials
Clinical trials are almost always required to support a PMA and are sometimes required to support a 510(k) submission. All clinical investigations of devices to determine safety and effectiveness must be conducted in accordance with the FDA’s investigational device exemption (“IDE”) regulations which govern investigational device labeling, prohibit promotion of the investigational device and specify an array of recordkeeping, reporting and monitoring responsibilities of study sponsors and study investigators. If the device presents a “significant risk” to human health, as defined by the FDA, the FDA requires the device sponsor to submit an IDE application to the FDA, which must become effective prior to commencing human clinical trials. If the device under evaluation does not present a significant risk to human health, then the device sponsor is not required to submit an IDE application to the FDA before initiating human clinical trials, but must still comply with abbreviated IDE requirements when conducting such trials. A significant risk device is one that presents a potential for serious risk to the health, safety or welfare of a patient and either is implanted, used in supporting or sustaining human life, substantially important in diagnosing, curing, mitigating or treating disease or otherwise preventing impairment of human health, or otherwise presents a potential for serious risk to a subject. An IDE application must be supported by appropriate data, such as animal and laboratory test results, showing that it is safe to test the device in humans and that the testing protocol is scientifically sound. The IDE will automatically become effective 30 days after receipt by the FDA unless the FDA notifies the Company that the investigation may not begin. If the FDA determines that there are deficiencies or other concerns with an IDE for which it requires modification, the FDA may permit a clinical trial to proceed under a conditional approval.
Regardless of the degree of risk presented by the medical device, clinical studies must be approved by, and conducted under the oversight of, an Institutional Review Board (“IRB”) for each clinical site. The IRB is responsible for the initial and continuing review of the IDE, and may pose additional requirements for the conduct of the study. If an IDE application is approved by the FDA and one or more IRBs, human clinical trials may begin at a specific number of investigational sites with a specific number of patients, as approved by the FDA. If the device presents a non-significant risk to the patient, a sponsor may begin the clinical trial after obtaining approval for the trial by one or more IRBs without separate approval from the FDA, but must still follow abbreviated IDE requirements, such as monitoring the investigation, ensuring that the investigators obtain informed consent and labeling and record-keeping requirements. Acceptance of an IDE application for review does not guarantee that the FDA will allow the IDE to become effective and, if it does become effective, the FDA may or may not determine that the data derived from the trials support the safety and effectiveness of the device or warrant the continuation of clinical trials. An IDE supplement must be submitted to, and approved by, the FDA before a sponsor or investigator may make a change to the investigational plan that may affect its scientific soundness, study plan or the rights, safety or welfare of human subjects.
During a study, the sponsor is required to comply with the applicable FDA requirements, including, for example, trial monitoring, selecting clinical investigators and providing them with the investigational plan, ensuring IRB review, adverse event reporting, record keeping and prohibitions on the promotion of investigational devices or on making safety or effectiveness claims for them. The clinical investigators in the clinical study are also subject to FDA regulations and must obtain patient informed consent, rigorously follow the investigational plan and study protocol, control the disposition of the investigational device and comply with all reporting and recordkeeping requirements. Additionally, after a trial begins, we, the FDA or the IRB could suspend or terminate a clinical trial at any time for various reasons, including a belief that the risks to study subjects outweigh the anticipated benefits.
Post-Market Regulation
After a device is cleared or approved for marketing, numerous and pervasive regulatory requirements continue to apply. These include:
establishment registration and device listing with the FDA;
QSR requirements, which require manufacturers, including third-party manufacturers, to follow stringent design, testing, control, documentation and other quality assurance procedures during all aspects of the design and manufacturing process;
labeling regulations and FDA prohibitions against the promotion of investigational products, or the promotion of “off-label” uses of cleared or approved products;
requirements related to promotional activities;
clearance or approval of product modifications to 510(k)-cleared devices that could significantly affect safety or effectiveness or that would constitute a major change in intended use of one of our cleared devices, or approval of certain modifications to PMA-approved devices;
medical device reporting regulations, which require that a manufacturer report to the FDA if a device it markets may have caused or contributed to a death or serious injury, or has malfunctioned and the device or a similar device that it markets would be likely to cause or contribute to a death or serious injury, if the malfunction were to recur;
correction, removal and recall reporting regulations, which require that manufacturers report to the FDA field corrections and product recalls or removals if undertaken to reduce a risk to health posed by the device or to remedy a violation of the FDCA that may present a risk to health;
the FDA’s recall authority, whereby the agency can order device manufacturers to recall from the market a product that is in violation of governing laws and regulations; and post-market surveillance activities and regulations, which apply when deemed by the FDA to be necessary to protect the public health or to provide additional safety and effectiveness data for the device.
Our manufacturing processes are required to comply with the applicable portions of the QSR, which cover the methods and the facilities and controls for the design, manufacture, testing, production, processes, controls, quality assurance, labeling, packaging, distribution, installation and servicing of finished devices intended for human use. The QSR also requires, among other things, maintenance of a device master file, device history file and complaint files. As a manufacturer, we will be subject to periodic scheduled or unscheduled inspections by the FDA. Our failure to maintain compliance with the QSR requirements could result in the shut-down of, or restrictions on, our manufacturing operations and the recall or seizure of our products, which would have a material adverse effect on our business. The discovery of previously unknown problems with any of our products, including unanticipated adverse events or adverse events of increasing severity or frequency, whether resulting from the use of the device within the scope of its clearance or off-label by a physician in the practice of medicine, could result in restrictions on the device, including the removal of the product from the market or voluntary or mandatory device recalls.
The FDA has broad regulatory compliance and enforcement powers. If the FDA determines that we failed to comply with applicable regulatory requirements, it can take a variety of compliance or enforcement actions, which may result in any of the following sanctions:
warning letters, untitled letters, fines, injunctions, consent decrees and civil penalties;
recalls, withdrawals or administrative detention or seizure of our products;
operating restrictions or partial suspension or total shutdown of production;
withdrawing 510(k) clearances or PMA approvals that have already been granted;
refusal to grant export approvals for our products; or
criminal prosecution.
Healthcare Regulatory Laws
Within the U.S., our products and our customers will be subject to extensive regulation by a wide range of federal and state agencies that govern business practices in the medical device industry. These laws include federal and state anti-kickback, fraud and abuse, false claims, transparency and anti-corruption statutes and regulations. Internationally, other governments also impose regulations in connection with their healthcare reimbursement programs and the delivery of healthcare items and services.
U.S. federal healthcare fraud and abuse laws will generally apply to our activities, among other reasons because we expect that our products will be covered under federal healthcare programs such as Medicare and Medicaid. The U.S. federal healthcare program Anti-Kickback Statute (the “Anti‑Kickback Statute”) is particularly relevant because of its broad applicability. Specifically, the Anti-Kickback Statute prohibits persons from knowingly and willfully soliciting, offering, receiving or providing remuneration, directly or indirectly, in exchange for, or to induce, either the referral of an individual, or the furnishing, arranging for or recommending a good or service for which payment may be made in whole or part under federal healthcare programs, such as the Medicare and Medicaid programs. Almost any financial interaction with a healthcare provider, patient or customer will implicate the Anti-Kickback Statute. Statutory exceptions and regulatory safe harbors protect certain interactions if specific requirements are met. However, only those interactions that represent fair market value exchanges generally are protected by a safe harbor or exception. The government can exercise enforcement discretion in taking action against unprotected activities. Further, a person or entity does not need to have actual knowledge of the Anti-Kickback Statute or specific intent to violate it in order to have committed a violation. In addition, the government may assert that a claim including items or services resulting from a violation of the federal Anti-Kickback Statute constitutes a false or fraudulent claim for purposes of the federal False Claims Act or federal civil money penalties statute. Penalties for Anti-Kickback Statute violations may include both criminal penalties such as imprisonment and civil sanctions such as fines, imprisonment and possible exclusion from Medicare, Medicaid and other federal healthcare programs. Exclusion would mean that diagnostic tests using our products would no longer be eligible for reimbursement under federal healthcare programs.
Many states have adopted laws similar to the Anti-Kickback Statute. Some of these state prohibitions apply to referral of patients for healthcare items or services reimbursed by any payor, not only federal healthcare programs. Insurance companies may also bring a private cause of action for treble damages against a manufacturer for a pattern of causing false claims to be filed under the federal Racketeer Influenced and Corrupt Organizations Act.
Another development affecting the healthcare industry is the increased use of the federal Civil False Claims Act and, in particular, actions brought pursuant to the False Claims Act’s “whistleblower” or “qui tam” provisions. The False Claims Act imposes liability on any person or entity that, among other things, knowingly presents, or causes to be presented, a false or fraudulent claim for payment by a federal healthcare program. The qui tam provisions of the False Claims Act allow a private individual to bring actions on behalf of the federal government alleging that the defendant has submitted a false claim to the federal government, and to share in any monetary recovery. In recent years, the number of suits brought against healthcare providers by private individuals has increased dramatically. In addition, various states have enacted false claim laws analogous to the Civil False Claims Act, although many of these state laws apply where a claim is submitted to any third-party payor and not merely a federal healthcare program.
The Health Insurance Portability and Accountability Act of 1996 (“HIPAA”), among other things, created two new federal crimes: healthcare fraud and false statements relating to healthcare matters. The HIPAA healthcare fraud statute prohibits, among other things, knowingly and willfully executing, or attempting to execute, a scheme to defraud any healthcare benefit program, including private payors. A violation of this statute is a felony and may result in fines, imprisonment and/or exclusion from government-sponsored programs. The HIPAA false statements statute prohibits, among other things, knowingly and willfully falsifying, concealing or covering up a material fact or making any materially false, fictitious or fraudulent statement or representation in connection with the delivery of or payment for healthcare benefits, items or services. A violation of this statute is a felony and may result in fines and/or imprisonment. Similar to the federal Anti-Kickback Statute, a person or entity does not need to have actual knowledge of the statutes or specific intent to violate them in order to have committed a violation.
Laws and regulations have also been enacted by the federal government and various states to regulate the sales and marketing practices of medical device and pharmaceutical manufacturers. The laws and regulations generally limit financial interactions between manufacturers and healthcare providers, require pharmaceutical and medical device companies to comply with voluntary compliance standards issued by industry associations and the relevant compliance guidance promulgated by the U.S. federal government and/or require disclosure to the government and/or public of financial interactions (so-called “sunshine laws”). Many of these laws and regulations contain ambiguous requirements or require administrative guidance for implementation. Manufacturers must adopt reasonable interpretations of requirements if there is ambiguity and those interpretations could be challenged. Given the lack of clarity in laws and their implementation, our activities could be subject to the penalty provisions of the pertinent federal and state laws and regulations.
Coverage and Reimbursement
Over the past few years, the growth rate of advanced imaging volumes has slowed in part due to additional patient-related cost-sharing programs and an increasing trend of third-party payors intensifying their utilization management efforts, for example, through benefit managers who require prior authorizations to control the growth rate of imaging services generally. We expect that these trends will continue.
By way of example, in the U.S., the Protecting Access to Medicare Act of 2014 required CMS, in conjunction with medical specialty societies, to adopt appropriate use criteria (“AUC”) for certain advanced diagnostic imaging services, including MRI, CT, nuclear medicine (including PET). Beginning in 2020, payment is made to the furnishing professional for an applicable advanced diagnostic imaging service only if the claim indicates that the ordering professional consulted a qualified clinical decision support mechanism, as identified by the Department of Health and Human Services (“HHS”), as to whether the ordered service adheres to the applicable AUC. Applicable settings include physician offices, hospital outpatient departments, including emergency departments, ambulatory surgical centers and independent diagnostic testing facilities. Advanced imaging services ordered by certain physicians identified as having outlier-ordering partners will be subject to prior authorization for applicable imaging services provided to Medicare beneficiaries. The outlier methodology used by CMS will be subject to future notice and comment rulemaking before the prior authorization component is implemented. We cannot predict the full impact of this project.
Third-party payors may impose limits on coverage or reimbursement for diagnostic imaging services, including denying reimbursement for tests that do not follow recommended diagnostic procedures or can only be billed using an unlisted or miscellaneous code. To the extent our customers will depend on third-party payors, unfavorable coding, coverage and reimbursement policies may constrict the profit margins of our provider customers, which may force us to lower our fees to attract and retain customers. If we are required to request new billing codes that more precisely identify and describe our imaging services, coverage is limited or reimbursement rates are inadequate, a healthcare provider might find it financially unattractive to own diagnostic imaging systems. It is possible that third-party payor coding, coverage and reimbursement policies will affect the need or prices for our products in the future, which could significantly affect our financial performance and our ability to conduct our business.
Healthcare Reform
In the U.S. and certain foreign jurisdictions, there have been, and we expect there will continue to be, a number of legislative and regulatory changes to the healthcare system. In March 2010, the Patient Protection and Affordable Care Act, and the Health Care and Education Reconciliation Act of 2010 (collectively, the “ACA”) was signed into law and substantially changed the way healthcare is financed by both governmental and private insurers in the United States. The ACA contains a number of provisions, including those governing enrollment in federal healthcare programs, reimbursement adjustments and fraud and abuse changes. Additionally, the ACA imposed, among other things, a new federal excise tax on the sale of certain medical devices, which, through a series of legislative amendments, was suspended, effective January 1, 2016, and subsequently repealed altogether on December 20, 2019, provided incentives to programs that increase the federal government’s comparative effectiveness research and implemented payment system reforms including a national pilot program on payment bundling to encourage hospitals, physicians and other providers to improve the coordination, quality and efficiency of certain healthcare services through bundled payment models. Since its enactment, there have been judicial and Congressional challenges to certain aspects of the ACA, and we expect there will be additional challenges and amendments to the ACA in the future.
Since its enactment, there have been judicial and Congressional challenges to certain aspects of the ACA, and we expect there will be additional challenges and amendments to the ACA in the future. By way of example, in 2017, Congress enacted the Tax Cuts and Jobs Act (the “TCJA”), which eliminated the tax-based shared responsibility payment imposed by the ACA on certain individuals who fail to maintain qualifying health coverage for all or part of a year that is commonly referred to as the “individual mandate.” On December 14, 2018, a Texas U.S. District Court Judge ruled that the individual mandate is a critical and inseverable feature of the ACA, and therefore, because it was repealed as part of the TCJA, the remaining provisions of the ACA are invalid as well. On December 18, 2019, the U.S. Court of Appeals for the 5th Circuit ruled that the individual mandate was unconstitutional and remanded the case back to the District Court to determine whether the remaining provisions of the ACA are invalid as well. However, the decision of the U.S. Court of Appeals for the 5th Circuit was appealed to the U.S. Supreme Court. On June 17, 2021, the U.S. Supreme Court held that the states that initially commenced the challenge to the ACA didn’t have standing to challenge the law, effectively ending this challenge. But it remains possible that future challenges to the ACA may be brought, and it is unclear how any future decisions and other efforts to repeal and replace the ACA will impact the ACA.
Other legislative changes have been proposed and adopted in the United States since the ACA was enacted, including aggregate reductions of Medicare payments to providers of 2% per fiscal year and reduced payments to several types of Medicare providers. We believe the overall escalating cost of medical products and services being paid for by the government and private health insurance has led to, and will continue to lead to, increased pressures on the healthcare and medical device industry to reduce the costs of products and services.
Data Privacy and Security
Medical device companies may be subject to U.S. federal and state and foreign health information privacy, security and data breach notification laws, which may govern the collection, use, disclosure and protection of health-related and other personal information. In the U.S., HIPAA imposes privacy, security and breach reporting obligations with respect to individually identifiable health information upon “covered entities” (health plans, health care clearinghouses and certain health care providers), and their respective business associates, individuals or entities that create, receive, maintain or transmit protected health information in connection with providing a service for or on behalf of a covered entity. HIPAA and its respective implementing regulations, including the final omnibus rule published on January 25, 2013, imposes specified requirements relating to the privacy, security and transmission of individually identifiable health information. HIPAA mandates the reporting of certain breaches of health information to HHS, affected individuals and if the breach is large enough, the media. Entities that are found to be in violation of HIPAA as the result of a breach of unsecured protected health information (“PHI”), a complaint about privacy practices or an audit by HHS, may be subject to significant civil, criminal and administrative fines and penalties and/or additional reporting and oversight obligations if required to enter into a resolution agreement and corrective action plan with HHS to settle allegations of HIPAA non-compliance. The Health Information Technology and Clinical Health Act also increased the civil and criminal penalties that may be imposed against covered entities, business associates and possibly other persons, and gave state attorneys general new authority to file civil actions for damages or injunctions in federal courts to enforce the federal HIPAA laws and seek attorney’s fees and costs associated with pursuing federal civil actions.
Even when HIPAA does not apply, according to the Federal Trade Commission (the “FTC”), failing to take appropriate steps to keep consumers’ personal information secure constitutes unfair acts or practices in or affecting commerce in violation of Section 5(a) of the Federal Trade Commission Act, 15 U.S.C § 45(a). The FTC expects a company’s data security measures to be reasonable and appropriate in light of the sensitivity and volume of consumer information it holds, the size and complexity of its business, and the cost of available tools to improve security and reduce vulnerabilities. Individually identifiable health information is considered sensitive data that merits stronger safeguards. The
FTC’s guidance for appropriately securing consumers’ personal information is similar to what is required by the HIPAA Security Rule.
In addition, certain state and non-U.S. laws, such as the European Union’s General Data Protection Regulation (2016/679) (“GDPR”), govern the privacy and security of health information in certain circumstances, some of which are more stringent than HIPAA and many of which differ from each other in significant ways and may not have the same effect, thus complicating compliance efforts. Further, “business associates,” defined as independent contractors or agents of covered entities that create, receive, maintain or transmit protected health information in connection with providing a service for or on behalf of a covered entity, are also subject to certain HIPAA privacy and security standards. Failure to comply with these laws, where applicable, can result in the imposition of significant civil and/or criminal penalties and private litigation. For example, California recently enacted legislation, the California Consumer Privacy Act (“CCPA”), which went into effect January 1, 2020. The CCPA, among other things, creates new data privacy obligations for covered companies and provides new privacy rights to California residents, including the right to opt out of certain disclosures of their information. The CCPA also creates a private right of action with statutory damages for certain data breaches, thereby potentially increasing risks associated with a data breach. Although the law includes limited exceptions, including for PHI maintained by a covered entity or business associate, it may regulate or impact our expected processing of personal information depending on the context. In Europe, the GDPR went into effect in May 2018 and introduces strict requirements for processing the personal data of European Union data subjects. Companies that must comply with the GDPR face increased compliance obligations and risk, including more robust regulatory enforcement of data protection requirements and potential fines for noncompliance of up to €20 million or 4% of the annual global revenues of the noncompliant company, whichever is greater. The State of Israel has also implemented data protection laws and regulations, including the Israeli Protection of Privacy Law of 1981.
Foreign Regulation
As we plan to market and deploy the QT Breast Scanner and products under development broadly across the globe, we will be subject to regulations applicable to medical and radiation-emitting devices in the jurisdictions in which we operate, which regulations vary among countries. While some countries’ regulations may not impose barriers to marketing and selling our products or only require certain notification, others may require that we obtain the clearance, registration or approval of a specified regulatory body. The process for obtaining such clearance, registration or approvals may involve additional testing and time. Furthermore, complying with foreign regulatory requirements can be expensive and time-consuming, and we will need to seek for regulatory clearances or approvals in each country in which we plan to market our products. In addition, depending on the country, if we modify our products, we may need to apply for additional regulatory clearances or approvals before we are permitted to sell the modified product. Also, for maintaining our authorizations in a particular country, we will need to continue meeting quality and safety standards required in such country. The Company may seek additional regulatory approvals outside of the U.S. but as of the date of this registration statement/prospectus, we do not have sufficient information to determine when, if ever, the Company will receive regulatory approval from any other jurisdictions.
Finally, while regulatory clearance or approval by the FDA does not ensure registration, clearance or approval by regulatory authorities in other countries, registration or regulatory clearance or approval in one country, or denial thereof, may have effects on the regulatory process in others.
Intellectual Property, Patents & Trademarks
QT Imaging has multiple U.S. and European patents and 5 registered U.S. trademarks. QT Imaging does not disclose its proprietary reconstruction algorithm technology. The details regarding this intellectual property is shown below.
The table below shows our utility patents and utility patent applications:
| JURISDICTION | NUMBER | TITLE | DATEFILED | DATEGRANTED | EXPIRATIONDATE | OWNER |
|---|---|---|---|---|---|---|
| US | US8827 908B2 | APPARATUS FOR ULTRASOUND IMAGING | 6/30/2011 | 9/9/2014 | 6/29/2032 | QT Imaging, Inc. and Esaote SpA |
| US | US9392 994B2 | APPARATUS AND METHOD FOR ULTRASOUND IMAGING WITH CONTRAST AGENTS | 4/5/2011 | 7/19/2016 | 11/19/2034 | QT Imaging, Inc. |
| US | US7771 360B2 | BREAST SCANNING SYSTEM | 4/8/2004 | 8/10/2010 | 6/10/2029 | QT Ultrasound LLC |
| JURISDICTION | NUMBER | TITLE | DATEFILED | DATEGRANTED | EXPIRATIONDATE | OWNER |
|---|---|---|---|---|---|---|
| US | US8366 617B2 | BREAST SCANNING SYSTEM | 5/14/2008 | 2/5/2013 | 11/18/2031 | QT Ultrasound LLC, CVUS Clinical Trials LLC |
| US | US7699 783B2 | METHOD FOR IMAGING AND TREATING A BREAST | 6/15/2005 | 4/20/2010 | 1/23/2027 | QT Ultrasound LLC |
| EP DE FR GB | EP1765 176B1 | METHOD OF IMAGING AND APPARATUS FOR IMAGING AND TREATING A BREAST | 6/16/2005 | 12/19/2012 | 6/16/2025 | Biotex Pharma Investments LLC |
| EP DE FR GB ES IT NL | EP2148 612B1 | BREAST SCANNING SYSTEM | 5/14/2008 | 1/6/2021 | 5/14/2028 | QT Ultrasound LLC |
| EP DE FR GB | EP1610 687B1 | BREAST SCANNING SYSTEM | 4/9/2004 | 1/23/2019 | 4/9/2024 | QT Ultrasound LLC |
| US | US1076 5402B2 | AUTOMATIC LATERALITY IDENTIFICATION FOR ULTRASOUND TOMOGRAPHY SYSTEMS | 11/23/2016 | 9/8/2020 | 12/1/2038 | QT Ultrasound LLC |
| US | US8246 543B2 | IMAGING METHOD UTILIZING ATTENUATION AND SPEED PARAMETERS IN INVERSE SCATTERING TECHNIQUES | 5/14/2008 | 8/21/2012 | 3/8/2031 | QT Ultrasound LLC, CVUS Clinical Trials LLC |
| EP | EP3843 627A4 | APPLICATION OF MACHINE LEARNING TO ITERATIVE AND MULTIMODALITY IMAGE RECONSTRUCTION | 8/30/2019 | PENDING | QT Imaging, Inc. | |
| US | US1117 0544B2 | APPLICATION OF MACHINE LEARNING TO ITERATIVE AND MULTIMODALITY IMAGE RECONSTRUCTION | 8/30/2019 | 11/9/2021 | 8/30/2039 | QT Imaging, Inc. |
| US | US1043 3818B2 | COLOR CODING AN IMAGE FOR IDENTIFYING ANATOMY USING QUANTITATIVE TRANSMISSION ULTRASOUND TOMOGRAPHY | 12/8/2017 | 10/8/2019 | 6/12/2038 | QT Ultrasound LLC |
| US | 18/888,547 | MEDICAL IMAGING TECHNIQUES INCLUDING ADAPTIVERECONSTRUCTION | 9/18/2024 | PENDING | QT Imaging, Inc. | |
| US | 18/955,499 | EVALUATION OF TOPOLOGICAL COMPLEXITY AND GENERATION OFQUANTITATIVE MARKERS IN MEDICAL IMAGES | 11/21/2024 | PENDING | QT Imaging, Inc. |
The table below shows our registered U.S. trademarks and trademark applications.
| TRADEMARKS · SERIAL NO · REGISTRATION · FILING DATE · Published forOpposition · Registration date | ||||||
|---|---|---|---|---|---|---|
| QT ULTRASOUND | 86295291 | 4729168 | 5/29/2014 | 10/21/2014 | 4/28/2015 | QT Imaging, Inc. |
| QTVIEWER | 5586707 | 87067439 | 6/10/2016 | 5/16/2017 | 10/16/2018 | QT Imaging, Inc. |
| QTSCAN | 87129339 | 5851942 | 8/5/2016 | 5/23/5017 | 9/3/2019 | QT Imaging, Inc. |
| QTBREASTHEALTH | 88059928 | 5991966 | 7/31/2018 | 9/24/2019 | 2/18/2020 | QT Imaging, Inc. |
| VOLOGRAPHY | 90329042 | 7183396 | 11/19/2020 | 6/8/2021 | 10/3/2023 | QT Imaging, Inc. |
| QT IMAGING | 98800489 | In the publication period | 10/14/2024 | QT Imaging, Inc. | ||
| Breast Acoustic CT | 98414186 | In the publication period | 2/21/2024 | QT Imaging, Inc. | ||
| Breast ACT | 98414157 | In the publication period | 2/21/2024 | QT Imaging, Inc. | ||
| Breast Acoustic Computed Tomography | 98414202 | In the publication period | 2/21/2024 | QT Imaging, Inc. | ||
The Company is monitoring research laboratories, commercial companies or universities developing ultra-low frequency transmitted sound imaging using inverse scattering image reconstruction. Therefore, the Company believes that its patent and proprietary position is currently substantial and a very valuable asset.
Employees
As of December 31, 2024, QT Imaging had 21 employees. Of these, 20 are full-time employees, 16 work in research, development, manufacturing, regulatory and operations, and 5 work in general and administrative capacities. 12 employees are located in Novato, CA. None of QT Imaging’s employees are represented by a labor union or are subject to a collective bargaining agreement.
Corporate and Available Information
Our corporate headquarters are located in Novato, California pursuant to a lease agreement that will expire on May 31, 2027. We believe that these facilities will be adequate for our near-term needs. If required, we believe that suitable additional or alternative space would be available in the future on commercially reasonable terms.
Our corporate website address is www.qtimaging.com. Information contained on our website is not a part of or incorporated by reference into this annual report or any other document we file with the SEC, and the inclusion of our website address in this annual report is inactive textual reference only.