Item 1. Business

Overview

EBR Systems, Inc., a Delaware corporation incorporated in 2003, is a U.S. based medical device company that is developing the WiSE CRT System, an implantable cardiac pacing system able to provide stimulation to endocardial heart tissue for the correction of heart rhythm conditions without requiring the use of wires or leads. This implantable, investigational device delivers left-ventricle endocardial pacing for cardiac resynchronization therapy (“CRT”), without the use of wires or leads going into the heart. An investigational device is one that has not been cleared or approved for commercial use by the U.S. Food and Drug Administration (the “FDA”). The left ventricle (“LV”) is a chamber of the heart responsible for pumping blood through the aorta to the rest of the body, such that ‘left-ventricle endocardial’ pacing refers to electrical pacing delivered inside the left ventricle of the heart. Conventional cardiac rhythm management (“CRM”) systems use leads to conduct electricity from an implantable pulse generator (“IPG”) to electrodes that deliver therapeutic electric pulses to heart tissue. While leads are a critical part of most CRM systems, they have long been recognized as a primary shortcoming of these systems and are a leading cause of device failure. Our leadless system is designed to address this shortcoming.

Our proprietary WiSE CRT technology is engineered to benefit patients who have not seen success with conventional CRT or face high complication risks. Conventional CRT has limitations related to the need for lead placement and complication risks of occlusion, infection or concurrent illness. By eliminating lead requirements for left ventricular pacing, WiSE CRT introduces a novel approach to cardiac pacing, with the potential to transform CRT delivery. If approved by the FDA, our system would allow clinicians to provide CRT for patients where a LV lead has failed or is deemed high-risk by their doctor. A patient in whom standard CRT upgrade is not advisable due to known relative contraindication to coronary sinus (“CS”) lead implant would be deemed high-risk by their doctor.

The initial focus of our WiSE CRT technology is to serve as an adjunct to existing implanted cardiac devices, providing CRT to those for whom traditional methods have failed or are not viable. In support of capturing this opportunity, WiSE CRT has been granted a Breakthrough Device Designation (“BDD”) by the FDA, which provides us with greater access to the FDA during the premarket review phase, a prioritized review process, and potentially up to three years of favorable reimbursement coverage in the U.S. following such approval. We completed a pivotal clinical study, SOLVE-CRT (Stimulation of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy) and submitted the final module of our modular pre-market approval (“PMA”) submission on August 28, 2024. For a more comprehensive discussion of the SOLVE-CRT study, see “SOLVE-CRT Clinical Trial” below.

Products

The WiSE CRT System, the Company’s only product candidate, is an implantable cardiac pacing system capable of delivering pacing level energy to the heart without using a lead/ wire. The technology used to achieve this leadless pacing is based on converting ultrasound energy to electrical energy. The system consists of a battery connected to an ultrasound transmitter that is implanted subcutaneously and the electrode implanted in the LV endocardium. The system requires a co-implant (e.g., pacemaker, defibrillator, or CRT) capable of right ventricular (“RV”) pacing. The transmitter senses the RV pacing spike of the co-implant and within approximately five milliseconds emits an ultrasonic pulse to the electrode, which converts the ultrasound energy received to electrical energy at sufficient amplitudes to pace/ stimulate cardiac tissue. The intensity of the ultrasound energy used is very low, even in comparison to levels used for echocardiographic imaging.

The leadless WiSE Electrode essentially replaces the pacing function of a traditional LV lead. The WiSE CRT System is used in conjunction with a typical, commercially available implanted pacemaker, implantable cardioverter defibrillator (“ICD”), or CRT device with an RV pacing function. Immediately after sensing an RV pacing output from the co-implanted device, the WiSE CRT System triggers an ultrasound pulse targeted at the Electrode to pace the left ventricle. The sequence of sensing, transmitting, receiving, and stimulating the left ventricle is essentially simultaneous with the co-implanted device’s RV pacing output and thus provides biventricular (“BiV”) pacing analogous to CRT pacing devices.

Components of the WiSE CRT System include the Delivery Sheath and Electrode Catheter which delivers the Electrode, the Pulse Generator (Transmitter and Battery), and the Programmer (Figure 1.1).

Figure 1.1 How WiSE CRT System Provides Leadless Cardiac Pacing

SOLVE-CRT Clinical Trial

The SOLVE-CRT investigational device exemption (“IDE”) study is a prospective, multicenter trial consisting of an initial randomized, double-blind part and a subsequent single-arm part. It was originally designed as a randomized, multinational, double-blind study to enroll 350 patients from up to 45 centers. Patients were enrolled if they received right ventricular (“RV”) pacing from a prior pacing implant and either did not have a fully functioning CRT system because of lead issues (Previously Untreatable [“PU”]), did not respond to CRT therapy (Non-Responders [“NR”]), or were considered high risk for a standard CRT upgrade (High-Risk Upgrade [“HRU”]), which included those with a cardiac pacemaker or intracardiac defibrillator (“ICD”) requiring upgrade to CRT.

The first patient was enrolled in the SOLVE-CRT study in January 2018. Enrollment was severely impacted by the COVID-19 pandemic and was paused in March 2020 after 108 patients were enrolled. At that time, the investigators worked with the FDA to revise the clinical protocol, implementing a single-arm, non-randomized part to complete the study. Central to this strategy was a differentiation of the three original patient groups and the requirements for demonstration of safety and efficacy. For the patients in the PU and HRU groups, CRT was an approved therapy, and the WiSE CRT System could be viewed as an alternate method of providing CRT when conventional CRT was not possible, so a Single-Arm study with pre-specified objective performance goals was appropriate. In contrast, the NR group had suboptimal responses to conventional CRT due to a diverse set of pathophysiologic mechanisms. Thus, there was a different threshold for scientifically acceptable evidence for safety and effectiveness, and this group was excluded from the study continuation.

The modified study was designed to enroll up to 300 patients with a pre-specified interim analysis with early stopping rules after enrolling 183 patients. All 183 patients (PU/HRU/NR) were included in the safety analysis while only the PU and HRU patients (n = 100) were included in the efficacy analysis. The primary safety endpoint was the freedom from device- or procedure-related complications (Type I). The primary efficacy endpoint was the reduction in left ventricular systolic volume (“LVESV”). LVESV is a key marker of advanced heart failure and goes up as the HF progresses. All versions of the study protocol were approved by relevant institutional review boards and the FDA under an IDE application. All patients provided written informed consent.

At the interim analysis, the primary 6-month efficacy endpoint was met with a 16.4% (95% confidence interval [“CI”], 11.7% to 21.0%) reduction in mean LVESV, significantly favorable to the 9.3% performance goal (p = 0.003). The primary 6-month safety endpoint was met with an 80.9% (148/183 participants) (lower boundary of the one-sided 98.8% CI, 73.4%) rate of freedom from device- or procedure-related (Type I) complications, significantly favorable to the 70% performance goal (p < 0.001). Since both the primary efficacy and safety endpoints met the pre-specified stopping rules for interim analysis, the trial was concluded early for success.

Secondary endpoints included an acoustic pacing capture threshold (“APCT”) of < 2.9 mJ achieved in 95.2% of participants and APCT stability achieved in 81.3% of participants, indicating that the WiSE CRT System was capable of delivering CRT in the majority of patients enrolled in the study and that the energy required to deliver CRT remained stable. In addition, 93.1% of participants achieved a mean percent BiV pacing, 46.1% achieved an increase in Left ventricular ejection fraction (“LVEF”) ≥ 5%, and 65.5% achieved an increase of ≥ 5 points in Kansas City Cardiomyopathy Questionnaire.

We are seeking to demonstrate with the SOLVE-CRT study that leadless left ventricular endocardial pacing (“LVEP”) with the novel WiSE CRT System is feasible, safe, and effective for delivering CRT in patients with advanced HF.

Clinical Conclusion

Subject to the review and determination by the FDA, we believe the performance and safety of the WiSE CRT System is supported by results of the SOLVE-CRT pivotal clinical trial, and peer-reviewed clinical literature. The System has a high implant success rate and delivers significant benefit to moderate to severe HF patients, including improved clinical and functional status and reverse remodeling. Further, complication rates observed with the WiSE CRT System are similar to those observed with other approaches to delivering CRT. The risks associated with the use of the System are acceptable when weighed against the potential benefits to the indicated patient populations. This is of particular importance as the patient populations treated in the EBR-sponsored studies have failed or not responded to conventional CRT and have a poor prognosis. Providing clinical benefit to these high-risk patients shows that the WiSE CRT System can meet the identified unmet clinical need for novel approaches to delivering CRT for the treatment of HF.

Further, we believe the design strategy for the WiSE CRT System results in a leadless device that is 95% smaller by volume compared to commercially available leadless pacemakers, such as Medtronic’s Micra or Abbott’s Aveir. Consequently, subject to approval by the FDA, we believe WiSE CRT will be the only therapy demonstrated in clinical study that can deliver LVEP and potentially broaden the spectrum of patients who could benefit from CRT.

Status of the FDA Review

We submitted the final module of our PMA submission on August 28, 2024. Under standard review, the FDA has 180 days to review the PMA. In January 2025, the FDA completed the manufacturing site Pre-Approval Inspection (“PAI”) with no Form FDA 483 observations. Thus, subject to FDA review and approval, and pre-commercial activities described under “Markets and Distribution” below, we expect to commercially launch the WiSE CRT System in the U.S. in 2025.

Markets and Distribution

If approved by the FDA and other regulatory authorities, we intend to commercially launch WiSE with the focus on driving adoption of WiSE at key, high-volume, luminary sites within the U.S. to be followed by select, high-volume sites in markets outside the U.S. (“OUS”) that we are targeting after evaluating regulatory and reimbursement considerations.

a)U.S. Strategy

We plan to implement a phased Limited Market Release (“LMR”), with the following phases:

LMR Phase 1: Initial Target Accounts

·Launch in target accounts from the SOLVE-CRT (Stimulation of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy) pivotal trial.
·Leverage existing relationships with trial sites to streamline patient identification and device implantation.

LMR Phase 2: Expansion and Optimization

·Strategically expand our field team to broaden our market presence into additional high-volume sites.
·Focus on optimizing the customer training programs and enhancing EBR's business operations.

LMR Phase 3: Increase Implants Per Site

·The field team will focus on increasing the number of cases per month per site by improving hospital implant workflows and familiarity with the technology.

Full Market Release

·Expand market presence and maximize product adoption.
·Utilize refined business operations and continue scaling the field team.
·Focus on expanding into additional sites, leveraging the experience and efficiency gained from the LMR.

If approved, we anticipate our average selling price (“ASP”) in the U.S. will be approximately $45,000 per WiSE CRT system. As a result of its breakthrough device designation (“BDD”), our WiSE CRT technology is expected to be eligible for incremental payment coverage in the U.S. for up to three years following potential FDA approval.

b)OUS Strategy

Our OUS commercial activities will not commence until we obtain regulatory approvals and certification in select, target markets. Regulatory submissions in these markets will not likely commence until sometime after FDA approval, if received. These initial target markets include Australia, the United Kingdom, and the European Union. The timing of launch in each of these OUS markets thus depends on meeting additional regulatory requirements, as well as on securing the appropriate payment coverage for WiSE in each market.

Competitive Environment

Significant advances in pacing technology have been made in pacing technology have been made over the last 50 years including: multi-chamber pacing, improved rate of responsiveness, devise size reduction, internet-based remote monitoring, and market increases in battery longevity. However, the basic system format of using an implantable pulse generator (“IPG”) connected to one or more leads to stimulate the heart muscle tissue, has remained unchanged over this time.

The most recent advance in the evolution of pacemakers has been the advent of leadless cardiac pacing systems, as most complications associated with pacemakers have been due to leads. To overcome this, leadless pacing systems have been developed in which the IPG and stimulating electrode are combined into a single unit that can be fully implanted inside the heart chamber. Advantages of this approach over lead-based systems include greater efficiency, system simplicity, and ease of implantation. However, these systems also have certain limitation, including the need to retrieve the device in future years due to battery depletion, risk of cardiac perforation and thrombus, and infection risk. Additionally, because of their size and thrombogenicity (tendency to generate and release clots that might cause heart attack or stroke) they cannot be used within the left ventricle.

The three major CRM device companies (Medtronic plc, Boston Scientific, and Abbott) have each developed leadless cardiac pacemakers that can be implanted in the right ventricle, with Abbott having an approved device that can be used in the right atrium. Leadless devices are expected to play an increasingly important role in the future pacemaker market.

Leadless Cardiac Rhythm Management Landscape

Figure 1.2: Current Leadless Pacemakers for Cardiac Pacing*

*CAUTION: The WiSE CRT System is an investigational device. Limited by Federal (US) law to investigational use only.

Opportunity for WiSE

While the leadless pacemakers currently on the market are for bradycardia indication, it is anticipated that the entry of Abbott’s Aveir DR dual chamber device could further increase the adoption of leadless pacemakers.

It has been reported that up to 30% of patients with pacemakers develop pacing induced heart failure within four years. Thus, many of the patients implanted with leadless pacemakers may require an upgrade to CRT at a later date. The WiSE CRT System is the only device able to upgrade these patients to CRT.

A 14-patient clinical study, presented during Asia-Pacific Heart Rhythm Society meeting in 2022, demonstrated that WiSE is able to work in conjunction with Medtronic’s Micra to provide BiV pacing and an entirely leadless option for upgrading these patients. Only WiSE can provide these patients with an entirely leadless upgrade solution.

Supply of Components

EBR’s WiSE CRT System is comprised of five key components:

·an implantable endocardial electrode (Electrode);
·a catheter delivery system (used to implant the Electrode);
·a transmitter that operates the system (Transmitter);
·a battery that powers the Transmitter; and
·a programmer (device that programs the WiSE CRT System).

We source components and sub-assemblies for components from external suppliers and contract manufacturers. We require our suppliers and contract manufacturers to be compliant with the relevant quality standards and certifications required to manufacture medical device products such as the WiSE CRT System.

We conduct our own quality assessment and performance testing of components and subassemblies that we receive from our suppliers. We have developed and maintain the software that runs the WiSE CRT System which is uploaded into the transmitter and programmer. We inspect and evaluate the entire system prior to supplying it for use in patients.

To date, production of our WiSE CRT System has been conducted on a small scale due to the low volumes required for clinical and product optimization studies. We believe that our existing suppliers have the capacity and capability to manufacture at volumes sufficient to meet the anticipated initial commercial demand for WiSE. We will likely seek to bring certain manufacturing processes in-house over time as we seek to reduce the cost of production. Many of the components or sub-assemblies used in the WiSE CRT System are custom built but use standard raw materials that can be provided by a variety of suppliers. Certain components within our sensor/transmitter and the receiver/transducer are unique to the WiSE CRT System design and functionality and would require redesign efforts if we need to change vendors arise. For instance**,** our piezo electric crystal is a single source component purchased from CTS Advanced Materials. We do not currently have a formal master supplier agreement in place with CTS as we generally procure on a purchase order basis. We work closely with our suppliers and have plans and measures in place to help ensure continuity of supply while maintaining high quality and reliability. Generally, we have been able to obtain adequate supplies of such raw materials and components. However, due to the U.S. FDA’s manufacturing requirements and those of other regulatory authorities, we may not be able to quickly establish additional or replacement sources for certain components or materials if we experience a sudden or unexpected reduction or interruption in supply and are unable to develop alternative sources.

Intellectual Property

The generation and protection of intellectual property, including patents, trade secrets, trademarks, proprietary technology, proprietary manufacturing techniques, and know-how, is of critical importance in our field and in biotechnology generally. We rely on a combination of trade secrets, patent filings and other intellectual property protections in an effort to protect our WiSE CRT System as well as related methods of use. We will be able to protect our WiSE CRT System and methods of use from unauthorized use by third parties only to the extent that our technology is effectively and diligently maintained as trade secrets or where applicable, covered by valid and enforceable patents. Our commercial success may also depend on whether we can defend our patents against third-party challenges and on operating without infringing on the intellectual property rights of others.

As of December 31, 2024, our WiSE CRT System and related technologies are covered by an extensive portfolio of patents which includes 63 granted U.S. patents, 55 granted non-U.S. patents, and 17 pending patent applications that cover different aspects of the WiSE CRT System including the technological inventions incorporated in:

·leadless cardiac pacing using ultrasound transduction;
·the sensor/transmitter;
·the receiver/stimulator electrode;
·the programmer;
·the delivery system; and
·mechanisms for detecting the location of the receiver/transducer electrode.

Our patents provide protection of the technology incorporated in the WiSE CRT System and a subset of these patents have expiry dates between 2025 and 2029. One pertinent patent related to the method of using an isotropic receiver-stimulator expires December 2025. However, other active patents (including patents in the same family) with device claims that provide similar coverage of the isotropic receiver-stimulator concepts and those directed to the overarching system and method are not expiring until 2032. Other patents directed to the technology incorporated in the WiSE CRT System expire 2030 and later. The United States has a mechanism, referred to as a patent term extension (“PTE”), for patent holders to extend the period of protection provided by their patents to compensate for time involved in conducting clinical studies and securing regulatory approval from the FDA. PTE is granted by the United States Patent and Trademark Office (“USPTO”) based on a formula and can extend the term of a patent by a maximum of five years. In view of the current timeline projected by us, PTE is expected to extend the expiry date for one of our key patents by four to five years depending on the timing of the FDA approval process. We will be able to file for PTE when and if the WiSE CRT System has been approved by the FDA.

We continue to conduct research and development activities directed at improving the use and performance of the WiSE CRT System and related technologies. This has resulted in the recent filing of new patent applications and may result in new inventions that potentially could provide opportunities to file additional patent applications. In addition, we have experience over many years with the WiSE CRT System and the underlying technology for providing leadless cardiac stimulation using ultrasound transduction. This has resulted in extensive know-how and trade secrets that are likely to represent significant barriers to any emerging competitors considering the development of a similar product.

Trade Secrets

We also rely on trade secrets, technical know-how and continuing innovation to develop and maintain our competitive position. We seek to protect our proprietary information with respect to our employees and collaborators by obtaining executed agreements requiring protection of our trade secrets and assignment of patents to us. Internal processes around the production of such things as the receiver electrode are complex and require extensive training and fixturing, lending credence to our technical know-how reliance.

Trade secrets are only beneficial if the trade secret can be protected, which in turn requires certain internal record keeping and security measures. Further, third parties are not precluded from practicing such trade secret methods developed on their own because there is no right to prevent others from this innovation. Trade secrets are difficult to protect and enforce and therefore provide us with only limited protection. Trade secrets must be protected within the company. Those employees and former employees with knowledge of our trade secrets must not share them with a third party. It is difficult to ensure that our trade secrets will be kept secret and not shared with a third party, such as a third-party competitor. For this and more comprehensive risks related to our intellectual property, please see “Item 1A. Risk Factors—Risks Related to Intellectual Property.”

Trademarks

We also have applied for and been awarded certain trademarks as shown in the table below. We intend to maintain and protect our trademarks from unauthorized use.

CountryTrademarkStatusReg. DateReg. No
AustraliaEBR SYSTEMSRegisteredDec 20 20212212887
AustraliaWISERegisteredNov 20 20191951115
ChinaEBR SYSTEMSRegisteredMar 28 202259571858
European UnionEBR SYSTEMSRegisteredFeb 22 202218564067
European UnionWISERegisteredFeb 5 202118169605
JapanEBR SYSTEMSRegisteredJan 24 20226503797
JapanWISERegisteredAug 11 20216427134
United KingdomEBR SYSTEMSRegisteredDec 24 2021UK00003698958
United KingdomWISERegisteredFeb 8 2021UK00003592127
United States of AmericaEBR SYSTEMSRegisteredNov 22 20226908275
United States of AmericaWICSRegisteredOct 6 20093692984
United States of AmericaWICS WIRELESS CARDIAC STIMULATIONRegisteredJan 10 20175118101
United States of AmericaWISERegisteredDec 13 20226925121
United States of AmericaWISERegisteredSep 19 20237169926

Government Regulation of Medical Devices

We intend to seek regulatory approval and certification for the WiSE CRT System in Australia, UK, and EU after initial commercialization in the U.S., pending FDA approval, and securing adequate reimbursement. We will evaluate the regulatory cost associated with securing CE Mark approval, which would allow it to be sold and used in countries within the E.U. and, potentially although not certainly, the U.K.

United States

Regulation of Medical Devices in the United States

The U.S. Food, Drug and Cosmetic Act (“FDCA”) classifies medical devices into one of three categories based on the risks associated with the device and the level of control necessary to provide reasonable assurance of safety and effectiveness. Class I devices are deemed to be low risk and are subject to the fewest regulatory controls. Class III devices are generally the highest risk devices and are subject to the highest level of regulatory control and premarket approval to provide reasonable assurance of the device’s safety and effectiveness.

Establishments that manufacture and/or distribute devices, including manufacturers, contract manufacturers, sterilizers, repackagers and relabelers, specification developers, reprocessors of single-use devices, remanufacturers, initial importers, manufacturers of accessories and components sold directly to the end user, and U.S. manufacturers of export-only devices, are required to register their establishments with the FDA and provide the FDA a list of the devices that they handle at their facilities.

Pre-market Authorization and Notification

While most Class I and some Class II devices can be marketed without prior FDA authorization, most medical devices can be legally sold within the U.S. only if the FDA has: (i) approved a premarket approval application, or PMA, prior to marketing, generally applicable to Class III devices; or (ii) cleared the device in response to a premarket notification, or 510(k) submission, generally applicable to Class I and II devices. Some devices that have been classified as Class III are regulated pursuant to the 510(k) requirements because the FDA has not yet called for PMAs for these devices. Other less common regulatory pathways to market for certain devices include the de novo classification process, the humanitarian device exception, or a product development protocol.

The 510(k) Clearance Process

Under the 510(k) process, the manufacturer must submit to the FDA a premarket notification, demonstrating that the device is “substantially equivalent” to a legally marketed predicate device.

A predicate device is a legally marketed device that is not subject to premarket approval, i.e., a device that was legally marketed prior to May 28, 1976, often referred to as a preamendment device, and for which a PMA is not required, a device that has been reclassified from Class III to Class II or I, or a device that was previously found substantially equivalent through the 510(k) process. To be “substantially equivalent,” the proposed device must have the same intended use as the predicate device, and either have the same technological characteristics as the predicate device or have different technological characteristics and not raise different questions of safety or effectiveness than the predicate device. Clinical data is sometimes required to support substantial equivalence.

After a 510(k) premarket notification is submitted, the FDA determines whether to accept it for substantive review. If it lacks necessary information for substantive review, the FDA will refuse to accept the 510(k) notification. If it is accepted for filing, the FDA begins a substantive review. By statute, the FDA has a performance goal to complete its review of 95% of 510(k) submissions within 90 days of receipt. As a practical matter, clearance often takes longer, because the FDA can request additional dates and information, which pauses the review clock for up to 180 days, and clearance is never assured. Although many 510(k) premarket notifications are cleared without clinical data, the FDA may require further information, including clinical data, to make a determination regarding substantial equivalence. If the FDA agrees that the device is substantially equivalent, it will grant clearance to commercially market the device.

If the FDA determines that the device is not “substantially equivalent” to a predicate device, or if the device is automatically classified into Class III, the device sponsor must then fulfill the much more rigorous premarketing requirements of the PMA approval process or seek reclassification of the device through the de novo process. A manufacturer can also submit a petition for direct de novo review if the manufacturer is unable to identify an appropriate predicate device and the new device or new use of the device presents a moderate or low risk.

After a device receives 510(k) clearance, any modification that could significantly affect its safety or effectiveness, or that would constitute a new or major change in its intended use, will require a new 510(k) clearance or, depending on the modification, could require a PMA application or de novo classification. The FDA requires each manufacturer to determine whether the proposed change requires submission of a 510(k) or a PMA in the first instance, but the FDA can review any such decision and disagree with a manufacturer’s determination. Many minor modifications are accomplished by a letter-to-file in which the manufacturer documents the change in an internal letter-to-file. If the FDA disagrees with a manufacturer’s determination regarding whether a new premarket submission is required for the modification of an existing device, the FDA can require the manufacturer to cease marketing and/or recall the modified device until 510(k) clearance or approval of a PMA application is obtained. In addition, in these circumstances, the FDA can impose significant regulatory fines or penalties for failure to submit the requisite PMA application(s).

The PMA Approval Process

Following receipt of a PMA application, the FDA conducts an administrative review to determine whether the application is sufficiently complete to permit a substantive review. If it is not, the agency will refuse to file the PMA. If it is, the FDA will accept the application for filing and begin the review. The FDA, by statute , has a performance goal to review 90% of PMA applications within 180 days, if advisory committee input is not required, and within 320 days, if advisory committee input is required, although the review of an application more often occurs over a significantly longer period of time. During this review period, the FDA may request additional information or clarification of information already provided, and the FDA may issue a major deficiency letter to the applicant, requesting the applicant’s response to deficiencies communicated by the FDA. The FDA considers a PMA or PMA supplement to have been voluntarily withdrawn if an applicant fails to respond to an FDA request for information (i.e., major deficiency letter) within a total of 360 days. Before approving or denying a PMA, an FDA advisory committee may review the PMA at a public meeting and provide the FDA with the committee’s recommendation on whether the FDA should approve the submission, approve it with specific conditions, or not approve it. The FDA is not bound by the recommendations of an advisory committee, but it considers such recommendations carefully when making decisions.

Prior to approval of a PMA, the FDA may conduct inspections of the clinical trial data and clinical trial sites, as well as inspections of the manufacturing facility and processes. Overall, the FDA review of a PMA application generally takes between one and three years but may take significantly longer. The FDA can delay, limit, or deny approval of a PMA application for many reasons, including:

·the device may not be shown safe or effective to the FDA’s satisfaction;
·the data from preclinical studies and/or clinical trials may be found unreliable or insufficient to support approval;
·the manufacturing process or facilities may not meet applicable requirements; and
·changes in FDA approval policies or adoption of new regulations may require requisite data.

If the FDA evaluation of a PMA is favorable, the FDA will issue either an approval letter, or an approvable letter, the latter of which usually contains a number of conditions that must be met in order to secure final approval of the PMA. When and if those conditions have been fulfilled to the satisfaction of the FDA, the agency will issue a PMA approval letter authorizing commercial marketing of the device, subject to the conditions of approval and the limitations established in the approval letter. If the FDA’s evaluation of a PMA application or manufacturing facilities is not favorable, the FDA will deny approval of the PMA or issue a not approvable letter. The FDA also may determine that additional tests or clinical trials are necessary, in which case the PMA approval may be delayed for several months or years while the trials are conducted and data is submitted in an amendment to the PMA, or the PMA is withdrawn and resubmitted when the data are available.

New PMA applications or PMA supplements are required for modification to the manufacturing process, equipment or facility, quality control procedures, sterilization, packaging, expiration date, labeling, device specifications, ingredients, materials, or design of a device that has been approved through the PMA process. PMA supplements often require submission of the same type of information as an initial PMA application, except that the supplement is limited to information needed to support any changes from the device covered by the approved PMA application and may or may not require as extensive technical or clinical data or the convening of an advisory panel, depending on the nature of the proposed change. In approving a PMA application, as a condition of approval, the FDA may also require some form of post-approval study or post-market surveillance, whereby the applicant conducts a follow-up study or follows certain patient groups for a number of years and makes periodic reports to the FDA on the clinical status of those patients when necessary to protect the public health or to provide additional or longer term safety and effectiveness data for the device. The FDA may also require post-market surveillance for certain devices , such as implants or life-supporting or life- sustaining devices used outside a device user facility. The FDA may also approve a PMA application with other post-approval conditions intended to ensure the safety and effectiveness of the device, such as, among other things, restrictions on labeling, promotion, sale, distribution, and use.

Breakthrough Device Designation (BDD)

FDA grants BDD to those devices that are intended to treat a serious or life-threatening disease or condition, and preliminary clinical evidence indicates that the product may demonstrate substantial improvement over existing therapies on one or more clinically significant endpoints, such as substantial treatment effects observed early in clinical development.

The BDD program provides more interactive and timely access to the FDA during the premarket development phase and submission process. This designation includes a prioritized review of regulatory filings and enhanced FDA guidance during the process. It also provides positive implications for incremental hospital payment from the Centers for Medicare and Medicaid Services (“CMS**”**).

Post-market Requirements

After a device is placed on the market, numerous regulatory requirements apply. These include: Quality System Regulation (“QSR”), labeling regulations, the FDA’s general prohibition against promoting products for unapproved or off-label uses, the Medical Device Reporting (“MDR”) regulation (which requires that manufacturers report to the FDA if their device may have caused or contributed to a death or serious injury or malfunctioned in a way that would likely cause or contribute to a death or serious injury if it were to recur), and the Reports of Corrections and Removals regulation (which requires manufacturers to report recalls and field actions to the FDA if initiated to reduce a risk to health posed by the device or to remedy a violation of the FDCA.

The FDA enforces these requirements by inspection and market surveillance. If the FDA finds a violation, it can institute a wide variety of enforcement actions, ranging from a public warning letter to more severe sanctions such as: fines, injunctions, and civil penalties; recall or seizure of products; operating restrictions, partial suspension or total shutdown of production; refusing requests for 510(k) clearance or PMA approval of new products; withdrawing 510(k) clearance or PMA approvals already granted; and criminal prosecution.

OUS

On May 26, 2021, Regulation (EU) 2017/745 on Medical Devices, entered into application, repealing and replacing both Directive 93/42/EEC concerning medical devices, and Directive 90/385/EEC concerning active implantable medical devices. The Regulation and its associated guidance documents and harmonized standards govern, among other things, device design and development, preclinical and clinical or performance testing, premarket conformity assessment, registration and listing, manufacturing, labeling, storage, claims, sales and distribution, export and import and post-market surveillance, vigilance, and market surveillance. Medical devices must comply with the General Safety and Performance Requirements, or GSPRs, set out in Annex I of the Medical Devices Regulation. Compliance with these requirements is a prerequisite to be able to affix the CE mark to devices, without which they cannot be marketed or sold in the European Economic Area (“EEA”). To demonstrate compliance with the GSPRs provided in the MDR and obtain the right to affix the CE mark, medical devices manufacturers must undergo a conformity assessment procedure, which varies according to the type of medical device and its classification. Apart from low risk medical devices (Class I with no measuring function and which are not sterile), in relation to which the manufacturer may issue an EU Declaration of Conformity based on a self-assessment of the conformity of its products with the GSPRs, a conformity assessment procedure requires the intervention of a Notified Body, which is an organization designated by a Competent Authority of an EEA country to conduct conformity assessments. Depending on the relevant conformity assessment procedure, the Notified Body will audit and examine the technical documentation and the quality system for the manufacture, design and final inspection of the medical devices. The Notified Body issues a CE Certificate of Conformity following successful completion of a conformity assessment procedure conducted in relation to the medical device and its manufacturer and their conformity with the GSPRs. This Certificate and the related conformity assessment process entitles the manufacturer to affix the CE mark to its medical devices after having prepared and signed a related EU Declaration of Conformity.

As a general rule, demonstration of conformity of medical devices and their manufacturers with the GSPRs must be based, among other things, on the evaluation of clinical data supporting the safety and performance of the products during normal conditions of use. Specifically, a manufacturer must demonstrate that the device achieves its intended performance during normal conditions of use and that the known and foreseeable risks, and any adverse events, are minimized and acceptable when weighed against the benefits of its intended performance, and that any claims made about the performance and safety of the device (e.g., product labeling and instructions for use) are supported by suitable evidence. This assessment must be based on clinical data, which can be obtained from (1) clinical studies conducted on the devices being assessed, (2) scientific literature from similar devices whose equivalence with the assessed device can be demonstrated or (3) both clinical studies and scientific literature. The conduct of clinical studies in the EEA is governed by detailed regulatory obligations. These may include the requirement of prior authorization by the Competent Authorities of the country in which the study takes place and the requirement to obtain a positive opinion from a competent Ethics Committee. This process can be expensive and time-consuming. After a device is placed on the market in the EEA, it remains subject to significant regulatory requirements.

The changes to the regulatory system implemented in the EU by the Medical Devices Regulation include stricter requirements for clinical evidence and pre-market assessment of safety and performance, new classifications to indicate risk levels, requirements for third party testing by Notified Bodies, tightened and streamlined quality management system assessment procedures and additional requirements for the quality management system, additional requirements for traceability of products and transparency as well as a refined responsibility of economic operators, and the requirement to provide clinical data in the form of a clinical evaluation report.

The UK has devised a new route to market culminating in a United Kingdom Conformity Assessment (“UKCA”) Mark to replace the CE Mark. Northern Ireland will, however, continue to be covered by the EU regulations governing CE Marks.

For a medical device to be sold and marketed in Australia, it must be included in the Australian Register of Therapeutic Goods (“ARTG”). For an active implantable medical device (“AIMD”)/Class III device, this is a two-stage process. The first stage involves an application to the Therapeutic Goods Administration (“TGA”) for a Declaration of Conformity. The second stage is an application for inclusion on the ARTG.

Other Healthcare Laws

In the United States, we are subject to a number of federal and state healthcare regulatory laws that restrict business practices in the healthcare industry. These laws include, but are not limited to, federal and state anti-kickback laws, false claims laws, data privacy and security laws, and other healthcare fraud and abuse laws, such as transparency laws regarding payments or other items of value provided to healthcare providers.

·The Anti-Kickback Statute, which prohibits, among other things, knowingly and willingly soliciting, offering, receiving or paying remuneration, directly or indirectly, overtly or covertly, in cash or in kind, to induce or reward either the referral of an individual, or the purchase, order or recommendation of, items or services for which payment may be made, in whole or in part, under a federal healthcare program, such as the Medicare and Medicaid programs. The term “remuneration” has been broadly interpreted to include anything of value, and the government can establish a violation of the Anti- Kickback Statute without proving that a person or entity had actual knowledge of the law or a specific intent to violate. In addition, the government may assert that a claim, including items or services resulting from a violation of the Anti-Kickback Statute, constitutes a false or fraudulent claim for purposes of the federal civil False Claims Act. The Anti-Kickback Statute is subject to evolving interpretations and has been applied by government enforcement officials to a number of common business arrangements in the medical device industry. There are a number of statutory exceptions and regulatory safe harbors protecting certain business arrangements from prosecution under the Anti- Kickback Statute; however, those exceptions and safe harbors are drawn narrowly, and there may be limited or no exception or safe harbor for many common business activities, such as reimbursement support programs, educational and research grants, or charitable donations. Practices that involve remuneration to those who prescribe, purchase, or recommend medical devices, including discounts, providing items or services for free or engaging such individuals as consultants, advisors, or speakers, may be subject to scrutiny if they do not fit squarely within an exception or safe harbor and would be subject to a facts and circumstances analysis to determine compliance with the Anti-Kickback Statute.
·Federal civil and criminal false claims laws, including the federal civil False Claims Act, and civil monetary penalties laws, which prohibit, among other things, persons or entities from knowingly presenting, or causing to be presented, a false or fraudulent claim for payment of government funds and knowingly making, using or causing to be made or used, a false record or statement to get a false claim paid or to avoid, decrease or conceal an obligation to pay money to the federal government. A claim including items or services resulting from a violation of the Anti-Kickback Statute constitutes a false or fraudulent claim for purposes of the federal civil False Claims Act. Actions under the federal civil False Claims Act may be brought by the government or as a qui tam action by a private individual in the name of the government. These individuals, sometimes known as “relators” or, more commonly, as “whistleblowers,” may share in any amounts paid by the entity to the government in fines or settlement. Many pharmaceutical and medical device manufacturers have been investigated and have reached substantial financial settlements with the federal government under the federal civil False Claims Act for a variety of alleged improper activities, including causing false claims to be submitted as a result of the marketing of their products for unapproved and thus non-reimbursable uses and interactions with prescribers and other customers, including those that may have affected their billing or coding practices and submission of claims to the federal government. Federal civil False Claims Act liability is potentially significant in the healthcare industry because the statute provides for treble damages and mandatory monetary penalties for each false or fraudulent claim or statement. Because of the potential for large monetary exposure, healthcare and medical device companies often resolve allegations without admissions of liability for significant and material amounts to avoid the uncertainty of treble damages and per claim penalties that may be awarded in litigation proceedings.
·Health Insurance Portability and Accountability Act (“HIPAA”), which imposes criminal and civil liability for, among other actions, knowingly and willfully executing, or attempting to execute, a scheme to defraud any healthcare benefit program, including private third-party payors, or knowingly and willfully falsifying, concealing or covering up a material fact or making a materially false, fictitious or fraudulent statement or representation, or making or using any false writing or document knowing the same to contain any materially false, fictitious or fraudulent statement or entry in connection with the delivery of or payment for healthcare benefits, items or services;
·HIPAA, as amended by the Health Information Technology for Economic and Clinical Health Act, or HITECH Act, and their implementing regulations, also impose obligations, including mandatory contractual terms, on covered entities subject to the rule, such as health plans, healthcare clearinghouses and certain healthcare providers, as well as their business associates and their subcontractors that perform certain services for them or on their behalf involving the use or disclosure of individually identifiable health information with respect to safeguarding the privacy, security and transmission of individually identifiable health information;
·The federal Physician Payments Sunshine Act, also known as Open Payments, which requires manufacturers of drugs, devices, biologics and medical supplies for which payment is available under Medicare, Medicaid or the Children’s Health Insurance Program to report annually, with certain exceptions, to the CMS information related to payments or other “transfers of value” made to physicians, (defined to include doctors, dentists, optometrists, podiatrists and chiropractors), certain other healthcare professionals (such as physician assistants and nurse practitioners), and teaching hospitals, and requires applicable manufacturers and group purchasing organizations to report annually to CMS ownership and investment interests held by physicians and their immediate family members; and
·Analogous state and foreign law equivalents of each of the above federal laws, such as anti-kickback and false claims laws which may apply to items or services reimbursed by any third-party payor, including commercial insurers; state and foreign laws that require medical device companies to comply with the industry’s voluntary compliance guidelines and the applicable compliance guidance promulgated by the federal government or otherwise restrict payments that may be made to healthcare providers and other potential referral sources; state and foreign beneficiary inducement laws, which are laws that require medical device manufacturers to report information related to payments and other transfers of value to physicians and other healthcare providers or marketing expenditures; and state and foreign laws governing the privacy and security of health information in certain circumstances, many of which differ from each other in significant ways and may not have the same effect, thus complicating compliance efforts. rem

Ensuring that our internal operations and business arrangements with third parties comply with applicable healthcare laws and regulations will likely be costly. It is possible that governmental authorities will conclude that our business practices do not comply with current or future statutes, regulations or case law involving applicable fraud and abuse or other healthcare laws and regulations. If our operations were found to be in violation of any of these laws or any other governmental regulations that may apply to us, we may be subject to significant civil, criminal and administrative penalties, damages, fines, disgorgement, imprisonment, possible exclusion from government funded healthcare programs, contractual damages, reputational harm, diminished profits and future earnings, additional reporting obligations and oversight if we become subject to a corporate integrity agreement or other agreement to resolve allegations of non-compliance with these laws, and curtailment of our operations, any of which could substantially disrupt our operations. If the physicians or other providers or entities with whom we expect to do business are found not to be in compliance with applicable laws, they may be subject to significant criminal, civil or administrative sanctions, including exclusions from government funded healthcare programs.

Healthcare Reform

In the United States and certain foreign jurisdictions, there have been, and we expect there will continue to be, a number of legislative and regulatory changes to the healthcare system. For example, implementation of the Patient Protection and Affordable Care Act, as amended by the Health Care and Education Affordability Reconciliation Act (collectively, the ACA) substantially changed the way healthcare is financed by both governmental and private insurers in the United States and significantly affected the pharmaceutical industry.

Since its enactment, there have been judicial, administrative, executive, and Congressional legislative challenges and amendments to certain aspects of the ACA. For example, on August 16, 2022, the Inflation Reduction Act of 2022 (“IRA”) was signed into law, which among other things, extends enhanced subsidies for individuals purchasing health insurance coverage in ACA marketplaces through plan year 2025. The IRA also eliminates the “donut hole” under the Medicare Part D program beginning in 2025 by significantly lowering the beneficiary maximum out-of-pocket cost and creating a new manufacturer discount program. It is unclear how such challenges and the healthcare reform measures of the Biden administration will impact the ACA.

Other legislative changes have been proposed and adopted since the ACA was enacted, including aggregate reductions of Medicare payments to providers of 2% per fiscal year pursuant to the Budget Control Act of 2011 which went into effect on April 1, 2013, and due to subsequent legislative amendments, will remain in effect until 2032, unless additional Congressional action is taken.

The current Trump administration is pursuing policies to reduce regulations and expenditures across government including at HHS, the FDA, the Centers for Medicare & Medicaid Services (“CMS”) and related agencies. These actions, presently directed by executive orders or memoranda from the Office of Management and Budget, may propose policy changes that create additional uncertainty for our business. These actions may, for example, include directives to reduce agency workforce, rescinding a Biden administration executive order tasking the Center for Medicare and Medicaid Innovation (“CMMI”) to consider new payment and healthcare models to limit drug spending and eliminating the Biden administration’s executive order that directed HHS to establishing an AI task force and developing a strategic plan. Additionally, in its June 2024 decision in Loper Bright Enterprises v. Raimondo (“Loper Bright”), the U.S. Supreme Court overturned the longstanding Chevron doctrine, under which courts were required to give deference to regulatory agencies’ reasonable interpretations of ambiguous federal statutes. The Loper Bright decision could result in additional legal challenges to current regulations and guidance issued by federal agencies applicable to our operations, including those issued by the FDA. Congress may introduce and ultimately pass health care related legislation that could impact the drug approval process.

Individual states in the United States have also become increasingly active in implementing regulations designed to control pharmaceutical and medical device product pricing, including price or patient reimbursement constraints, discounts, restrictions on certain product access and marketing cost disclosure and transparency measures and, in some cases, mechanisms to encourage importation from other countries and bulk purchasing. In addition, regional healthcare authorities and individual hospitals are increasingly using bidding procedures to determine which products and supplies will be included in their healthcare programs. Furthermore, there has been increased interest by third-party payors and governmental authorities in reference pricing systems and publication of discounts and list prices.

We expect additional state and federal healthcare reform measures to be adopted in the future, any of which could limit the amounts that federal and state governments will pay for healthcare products and services.

Reimbursement

Potential reimbursement pathways vary by target markets.

United States

In the United States, sales of our products will depend substantially on the extent to which the costs of our products will be paid by health maintenance, managed care, pharmacy benefit and similar healthcare management organizations, or reimbursed by government health care programs, private health coverage insurers and other third-party payors. Third-party payors decide which treatments they will cover and establish reimbursement rates for those treatments. Our products are purchased by hospitals and other providers who will then seek reimbursement from third-party payors for the procedures performed using our products. Private payors often, but not always, follow CMS’s decisions regarding coverage and reimbursement under the Medicare program. If sufficient coverage and reimbursement is not available for the procedures using our products, the demand for our products and our revenue will be adversely affected.

Current Procedural Terminology (CPT) codes are utilized to report services provided by physicians and other qualified healthcare professionals. Other providers may also utilize CPT codes to report services, including hospital outpatient departments and ambulatory surgery centers. Currently, there are eight Category III CPT codes that describe the various procedures related to WiSE. We will coordinate with relevant professional physician societies to convert the Category III CPT codes to Category I CPT codes when appropriate. Category I CPT codes are utilized to establish a Medicare national payment level for physician services.

For hospital payment for Medicare patients, WiSE currently maps to existing Medicare Severity Diagnosis Related Groups (MS-DRGs) for hospital inpatient procedures, and Ambulatory Payment Classifications (APCs) for hospital outpatient procedures. It is expected that the vast majority of Medicare patients receiving WiSE will be implanted in the hospital inpatient or outpatient setting.

Additionally, CMS (Medicare) provides an opportunity for select new technologies that meet pre-specified criteria to receive incremental payment in the hospital setting. For hospital inpatient procedures, the New Technology Add-On Payment (NTAP) provides incremental payment to hospitals for 2-3 years in addition to the MS-DRG payment. For hospital outpatient procedures, the Transitional Pass-Through (TPT) provides incremental payment to hospitals for 3 years in addition to the APC payment. Once the NTAP and TPT expire, CMS utilizes the claims data from WiSE CRT procedures to update MS-DRG and APC payment rates based on standard payment policy.

As stated above, the WiSE CRT System has received a BDD from the FDA. CMS has established policies that for technologies with BDD, two of the three qualifying criteria for NTAP are automatically deemed to be met. Thus, the probability of the WiSE CRT System securing NTAP, and incremental payment for 2-3 years is high. For TPT, technologies with BDD are deemed to automatically meet the “substantial clinical improvement” criterion, which significantly increases the probability of securing TPT.

Third-party payors are also increasingly examining the cost effectiveness of products, in addition to their safety and efficacy, when making coverage and payment decisions. Third-party payors have also instituted initiatives to limit the growth of healthcare costs using, for example, price regulation or controls and competitive pricing programs. Some third-party payors also require demonstrated superiority, on the basis of randomized clinical trials, or pre-approval of coverage, for new or innovative devices or procedures before they will reimburse healthcare providers who use such devices or procedures. Additionally, no uniform policy for coverage and reimbursement exists in the United States, and coverage and reimbursement can differ significantly from payor to payor. Third-party payors often rely upon Medicare coverage policy and payment limitations in setting their own reimbursement rates, but also have their own methods and approval process apart from Medicare determinations. Coverage policies and third-party reimbursement rates may change at any time. Even if favorable coverage and reimbursement status is attained for one or more products for which we or our collaborators receive regulatory approval, less favorable coverage policies and reimbursement rates may be implemented in the future. It is uncertain whether our current products or any planned or future products will be viewed as sufficiently cost effective to warrant coverage and adequate reimbursement levels for procedures using such products in any given jurisdiction.

Jurisdiction of Incorporation

We are incorporated in the State of Delaware, United States of America, and are a registered foreign company in Australia. As a foreign company registered in Australia, we are subject to different reporting and regulatory regimes than Australian companies. As a foreign company registered in Australia, we are not subject to Chapters 6, 6A, 6B and 6C of the Corporations Act 2001 (Cth) of Australia (“Corporations Act”) dealing with the acquisition of shares (including substantial shareholdings and takeovers).

Employees

As of December 31, 2024, we had 89 full-time employees including 79 in research and development and 10 in general and administrative. As of December 31, 2024, we had 79 employees located in the U.S., six in Europe, and four in Australia. None of our employees are represented by a labor union or covered by a collective bargaining agreement. We consider our relations with our employees to be good.

Available Information

Copies of our Annual Reports on Form 10-K, Quarterly Reports on Form 10-Q, Current Reports on Form 8-K, proxy statements as well as any amendments to those reports, are filed or furnished with the Securities and Exchange Commission (the “SEC”). Such reports and other information filed by the Company with the SEC are available on our website at https://www.ebrsystemsinc.com/ as soon as reasonably practicable after it is electronically filed with the SEC. References to our website address do not constitute incorporation by reference of the information contained on the website, and the information contained on the website is not part of this document. The SEC maintains an Internet site that contains reports, proxy and information statements and other information regarding issuers that file electronically with the SEC at www.sec.gov.